Hostname: page-component-cd9895bd7-gvvz8 Total loading time: 0 Render date: 2024-12-26T16:08:00.285Z Has data issue: false hasContentIssue false

P147: International scope of emergency ultrasound: barriers to utilizing ultrasound to guide central venous catheter placement by providers in Kenya

Published online by Cambridge University Press:  02 June 2016

F. Zaver
Affiliation:
George Washington University Hospital, Washington, DC
K. Boniface
Affiliation:
George Washington University Hospital, Washington, DC
H. Shokoohi
Affiliation:
George Washington University Hospital, Washington, DC
B. Wachira
Affiliation:
George Washington University Hospital, Washington, DC
G. Wanjiku
Affiliation:
George Washington University Hospital, Washington, DC

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Introduction: While ultrasound (U/S) use for internal jugular central venous catheter (CVC) placement is standard of care in many institutions in North America, most developing countries have not adopted this practice. Previous surveys of American physicians who are not currently using U/S to place CVCs have identified lack of training and equipment availability as the most important barriers to the use of U/S. We sought to identify Kenyan physicians’ perceived barriers to the use of U/S to guide CVC insertion in a resource-constrained environment. Methods: The study was conducted at the Aga Khan University Hospital in Nairobi, Kenya. Physicians participating in a one-hour course teaching U/S guided CVC placement were asked to complete a survey before beginning training, which was used to assess previous experience with U/S, and evaluate perceived barriers to U/S. Survey responses were analyzed using summary statistics and the Rank-Sum test to compare the difference between participants’ responses based on different specialty, gender and previous history of using U/S. Results: There were 23 physicians who completed the course and the survey. They included 6 internal medicine, 5 critical care, 5 anesthesia, 2 emergency medicine and 5 physicians from other specialties. The mean length of practice was 5 years. 52% (95% CI: 0.30-0.73) had put in >20 CVCs. 21.7% (95% CI: 0.08-0.44) of participants had previous U/S training, but none have received any training on the use of U/S for CVC insertion. The respondents expressed agreement on the ease of the use, improved success rate, and decreased failure rate with U/S guidance. However, less agreement was found regarding the perceived superior convenience and cost effectiveness of U/S CVC placement (see Figure). The lack of training or comfort with the U/S and the availability of U/S and equipment to maintain sterility were reported as the main barriers for use. Neither previous U/S experience nor specialty of the respondent significantly affected responses. Conclusion: Barriers to the use of U/S guidance for the placement of CVCs in Nairobi, Kenya are similar to those found among American physicians. These include training and comfort level with U/S in placement of CVCs, as well as resources required for U/S equipment and to keep the field sterile.

Type
Posters Presentations
Copyright
Copyright © Canadian Association of Emergency Physicians 2016