No CrossRef data available.
Published online by Cambridge University Press: 26 March 2019
OBJECTIVES/SPECIFIC AIMS: 1. Determine positive predictive value, negative predictive value, sensitivity, and specificity of Neuro ICU nurse interpretation of real-time bedside qEEG. 2. Determine difference in time to detection of first seizure between Neuro ICU nurse qEEG interpretation and EEG fellow reads of cEEG. 3. Determine what qualities of seizures make detection by neuro ICU nurses more or less likely – e.g. duration of seizures, type of seizures, spatial extent of seizures. METHODS/STUDY POPULATION: Recruit neuro ICU nurses taking care of 150 patients admitted to the Neuro ICU at Duke University Hospital who are initiated on cEEG monitoring. Nurses will be consented for their participation in the study. Neuro ICU nurses will evaluate the qEE RESULTS/ANTICIPATED RESULTS: From literature estimates of a 20% seizure prevalence in critical care settings, we hope to have 30 patients with seizures and 120 without. Based on prior study in the Duke Neuro ICU, we hypothesize that Neuro ICU nurses will have sensitivity and DISCUSSION/SIGNIFICANCE OF IMPACT: This is the first prospective study of neuro ICU nurse interpretation of real-time bedside qEEG in patients with unknown NCSE/NCS presence. If nurse sensitivity, specificity, and positive predictive value are clinically useful, which we deem would be so at a sensitivity of 70% or greater, with acceptable false alarm rate, nurse readings of qEEG could significantly decrease the time to treatment of seizures in the Neuro ICU patient population, and perhaps could improve patient outcomes.