Hostname: page-component-cd9895bd7-hc48f Total loading time: 0 Render date: 2024-12-27T06:35:04.572Z Has data issue: false hasContentIssue false

A Complication of indoor pistol shooting

Published online by Cambridge University Press:  29 June 2007

S. A. White*
Affiliation:
Department of Otolaryngology, Leicester Royal Infirmary, UK
A. A. Narula
Affiliation:
Department of Otolaryngology, Leicester Royal Infirmary, UK
*
Address for correspondence: Dr S. A. White, University of Leicester, PO. Box 65, Clinical Sciences Building, Leicester LE2 2BB.

Abstract

The aetiology of chronic rhinitis and nasal obstruction is often elusive and obscure. Many different causes have been documented including allergens, cigarette smoke, cold dry air, viruses, sulphur dioxide and industrial pollutants. This is the first case we have been able to identify of rhinitis associated with exposure to high levels of lead through indoor pistol shooting.

Type
Clinical Records
Copyright
Copyright © JLO (1984) Limited 1996

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Albahary, C. (1979) Lead and hemopoiesis. American Journal of Medicine 52: 367378.CrossRefGoogle Scholar
Ballenger, J. J. (1991) Chronic rhinitis and nasal obstruction. In Diseases of Nose, Throat, Ear, Head and Neck (Ballenger, J. J., ed.), Lea and Febiger, Philadelphia, USA, pp 140142.Google Scholar
Fischbein, A., Rice, C., Sarkozi, L., Kon, S. H., Petrocci, M., Selikoff, I. J. (1979) Exposure to lead in firing ranges. Journal of the American Medical Association 241: 11411144.Google Scholar
Grandjean, P., Lintrup, J. (1978) Erythrocyte Zn-protoporphyrin as an indicator of lead exposure. Scandinavian Journal of Laboratory Investigation 38: 669675.Google Scholar
H.M.S.O. (1985) Approved Code of Practice Control of Lead at Work. 0-11-883780X piii.Google Scholar
Ozonoff, D. (1994) Lead on the range. Lancet 343: 67.CrossRefGoogle ScholarPubMed
Valway, S. E., Martyny, J. W., Miller, J. R., Cook, M., Mangione, E. (1989) Lead absorption in indoor firing range users. American Journal of Public Health 79: 10291032.CrossRefGoogle ScholarPubMed