Hostname: page-component-78c5997874-s2hrs Total loading time: 0 Render date: 2024-11-10T08:19:55.671Z Has data issue: false hasContentIssue false

Regarding ‘Effect of surgery, delivery device and head position on sinus irrigant penetration in a cadaver model’

Published online by Cambridge University Press:  23 June 2021

S Sureshkumar
Affiliation:
Department of ENT, Al Azhar Medical College and Super Specialty Hospital, Thodupuzha, Kerala, India
D T Pulimoottil
Affiliation:
Department of ENT, Al Azhar Medical College and Super Specialty Hospital, Thodupuzha, Kerala, India
R M Sherif
Affiliation:
Department of ENT, Al Azhar Medical College and Super Specialty Hospital, Thodupuzha, Kerala, India
Rights & Permissions [Opens in a new window]

Abstract

Type
Letter to the Editors
Copyright
Copyright © The Author(s), 2021. Published by Cambridge University Press

Dear Editors,

We read with great interest the article titled ‘Effect of surgery, delivery device and head position on sinus irrigant penetration in a cadaver model’ by Mozzanica et al.Reference Mozzanica, Preti, Bandi, Fazio, Cardella and Gallo1 in your esteemed journal. It is a succinctly written article and we would like to commend the authors on their excellent effort. This is an area of interest for us and we are currently conducting a study on the same. Hence, we would like to highlight a few more points that we feel would enrich the article further.

The authors pointed out that there is no significant advantage of the head position for irrigation of the sphenoid sinuses. In contrast, Craig et al.Reference Craig, Palmer and Zhao2 assert that the ‘nose-to-ceiling’ position can improve sphenoid sinus penetration of irrigation after sinus surgical procedures. This was demonstrated in their computational fluid dynamics model, which showed good penetration of sphenoid sinuses, both ipsilateral and contralateral to the side of irrigation. Similarly, our observations in our ongoing study also show that in patients with recalcitrant sphenoid sinus disease, nose-to-ceiling head positioning can improve mechanical lavage and medication delivery to the sphenoid sinus.

We agree that high-volume, high-pressure devices for sinus irrigation yield better results in post-operative patients, which has been our experience too. Thomas et al.Reference Thomas, Harvey, Rudmik, Hwang and Schlosser3 recommend the use of high-volume devices to overcome unfavourable nasal anatomy, and Barham et al.Reference Barham, Hall, Hernandez, Zylicz, Stevenson and Zito4 suggest a delivery device volume of more than 100 ml to achieve effective delivery into the sinuses. Taken together, this would suggest that if the volume of topical agent used is sufficiently large enough to fill the nasal cavity and propel the topical agents into the paranasal sinuses, then head positioning would be a secondary consideration.

It was interesting to note there was no improvement in irrigation after a Draf III procedure over a Draf IIa procedure. This is in contrast to the dramatic improvement observed after the Draf III procedure in the study by Barham et al.Reference Barham, Hall, Hernandez, Zylicz, Stevenson and Zito4 On a related note, Spielman et al.Reference Spielman, Kim, Overdevest and Gudis5 inferred that achieving zero-degree visualisation of the frontal recess intra-operatively by resecting the middle turbinate axilla – agger nasi complex in a standard Draf IIa frontal sinusotomy can significantly improve post-operative irrigant penetration. This is an area of divergence that requires further study.

References

Mozzanica, F, Preti, A, Bandi, F, Fazio, E, Cardella, A, Gallo, S et al. Effect of surgery, delivery device and head position on sinus irrigant penetration in a cadaver model. J Laryngol Otol 2021;135:234–4010.1017/S0022215120002662CrossRefGoogle Scholar
Craig, JR, Palmer, JN, Zhao, K. Computational fluid dynamic modelling of nose-to-ceiling head positioning for sphenoid sinus irrigation. Int Forum Allergy Rhinol 2017;7:474–910.1002/alr.21908CrossRefGoogle Scholar
Thomas, WW 3rd, Harvey, RJ, Rudmik, L, Hwang, PH, Schlosser, RJ. Distribution of topical agents to the paranasal sinuses: an evidence-based review with recommendations. Int Forum Allergy Rhinol 2013;3:69170310.1002/alr.21172CrossRefGoogle ScholarPubMed
Barham, HP, Hall, CA, Hernandez, SC, Zylicz, HE, Stevenson, MM, Zito, BA et al. Impact of Draf III, Draf IIb and Draf IIa frontal sinus surgery on nasal irrigation distribution. Int Forum Allergy Rhinol 2020;10:495210.1002/alr.22447CrossRefGoogle ScholarPubMed
Spielman, DB, Kim, M, Overdevest, J, Gudis, DA. Zero-degree endoscopic visualization of the frontal sinus predicts improved topical irrigation delivery. Laryngoscope 2021;131:250–410.1002/lary.28654CrossRefGoogle ScholarPubMed