Vibrant Soundbridge system: application of the stapes coupling technique

Published online by Cambridge University Press:  07 December 2012

W S S Tsang
Affiliation:
Department of Otorhinolaryngology, Head and Neck Surgery and The Institute of Human Communicative Research, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong SAR, China
J K Y Yu
Affiliation:
Department of Otorhinolaryngology, Head and Neck Surgery and The Institute of Human Communicative Research, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong SAR, China
T K C Wong
Affiliation:
Department of Otorhinolaryngology, Head and Neck Surgery and The Institute of Human Communicative Research, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong SAR, China
M C F Tong*
Affiliation:
Department of Otorhinolaryngology, Head and Neck Surgery and The Institute of Human Communicative Research, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong SAR, China
*
Address for correspondence: Dr Michael C F Tong, Department of Otorhinolaryngology, Head and Neck Surgery and The Institute of Human Communicative Research, The Chinese University of Hong Kong, Prince of Wales Hospital, Ngan Shing St, Shatin, Hong Kong SAR, China Fax: +852 21458876 E-mail: mtong@cuhk.edu.hk

Abstract

Introduction:

The use of the stapes coupling technique, employed in the Vibrant Soundbridge system, is technically less demanding than the vibroplasty technique, and is more likely to generate a positive outcome without significantly changing residual hearing or resulting in medical or surgical complication.

Method:

We report a patient with repeated left ossiculoplasty failure, who was successfully implanted with a Vibrant Soundbridge.

Conclusion:

We believe that the stapes coupling technique can provide natural stimulation to the inner ear, resulting in a better perceived sound quality.

Type
Short Communications
Copyright
Copyright © JLO (1984) Limited 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Tsang, WSS, Wong, TKC, Tong, MCF. Vibrant Soundbridge System: round window stimulation with the vibroplasty technique. Ear Nose Throat J 2011;90:E39CrossRefGoogle ScholarPubMed
2 Colletti, V, Soli, SD, Carner, M, Colletti, L. Treatment of mixed hearing losses via implantation of a vibratory transducer on the round window. Int J Audiol 2006;45:600–8CrossRefGoogle ScholarPubMed
3 De la Cruz, A, Teufert, KB. Congenital aural atresia surgery: long-term results. Otolaryngol Head Neck Surg 2003;129:121–7Google ScholarPubMed
4 Uziel, A, Mondain, M, Hagen, P, Dejean, F, Doucet, G. Rehabilitation for high frequency sensori-neural hearing impairment in adults with the Symphonix Vibrant Soundbridge: a comparative study. Otol Neurotol 2003;24:775–83CrossRefGoogle Scholar
5 Ashburn-Reed, S. The first FDA approved middle ear implant: the Vibrant Soundbridge. The Hearing Journal 2001;54:47–8CrossRefGoogle Scholar
6 Radeloff, A, Shehata-Dieler, W, Rak, K, Scherzed, A, Tolsdorff, B, Hagen, R et al. Intraoperative monitoring of active middle ear implant function in patients with normal and pathologic middle ears. Otol Neurotol 2011;32:104–7CrossRefGoogle ScholarPubMed