Hostname: page-component-78c5997874-m6dg7 Total loading time: 0 Render date: 2024-11-11T03:31:18.124Z Has data issue: false hasContentIssue false

Imaging of Cellular Dynamics by Two-Photon Excitation Microscopy

Published online by Cambridge University Press:  08 August 2003

David W. Piston
Affiliation:
Department of Molecular Physiology and Biophysics, Vanderbilt University, 702 Light Hall, Nashville, TN 37232
Brian D. Bennett
Affiliation:
Department of Molecular Physiology and Biophysics, Vanderbilt University, 702 Light Hall, Nashville, TN 37232
Guangtao Ying
Affiliation:
Department of Molecular Physiology and Biophysics, Vanderbilt University, 702 Light Hall, Nashville, TN 37232
Get access

Abstract

Two-photon excitation fluorescence microscopy provides attractive advantages over confocal microscopy for three-dimensionally resolved fluorescence imaging. Two-photon excitation arises from the simultaneous absorption of two photons in a single quantitized event whose probability is proportional to the square of the instantaneous intensity. For example, two red photons (∼700 nm) can cause the transition to an excited electronic state normally reached by absorption in the ultraviolet (∼350 nm). In the fluorescence experiments described here, the final excited state is the same singlet state that is populated during a conventional fluorescence experiment. Thus, the fluorophore exhibits the same emission properties (e.g., wavelength shifts, environmental sensitivity) used in typical biological microscopy studies. Three properties of two-photon excitation give this method its advantage over conventional optical sectioning microscopies: (1) the excitation is limited to the focal volume, thus providing inherent three-dimensional resolution and minimizing photobleaching and photodamage; (2) the two-photon technique allows imaging of UV fluorophores with only conventional visible light optics; (3) red light is far less damaging to most living cells and tissues than UV light and permits deeper sectioning, because both absorbance and scattering are reduced. Many cell biological applications of two-photon excitation microscopy have been successfully realized, demonstrating the wide ranging power of this technique.

Type
Research Article
Copyright
© 1995 Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)