Hostname: page-component-cd9895bd7-gxg78 Total loading time: 0 Render date: 2024-12-27T22:04:25.136Z Has data issue: false hasContentIssue false

Three-Dimensional Microscopic Elemental Analysis Using an Automated High-Precision Serial Sectioning System

Published online by Cambridge University Press:  02 March 2011

Kazuhiro Fujisaki
Affiliation:
Division of Human Mechanical Systems and Design, Graduate School of Engineering, Hokkaido University, N13 W8, Kita-ku, Sapporo 060-8628, Japan Bio-Research Infrastructure Construction Team, RIKEN, 2-1, Hirosawa, Wako, Saitama 351-0198, Japan
Hideo Yokota*
Affiliation:
Division of Human Mechanical Systems and Design, Graduate School of Engineering, Hokkaido University, N13 W8, Kita-ku, Sapporo 060-8628, Japan Bio-Research Infrastructure Construction Team, RIKEN, 2-1, Hirosawa, Wako, Saitama 351-0198, Japan Biomechanical Simulation Research Team, RIKEN, Wako, Saitama 351-0198, Japan
Naomichi Furushiro
Affiliation:
Bio-Research Infrastructure Construction Team, RIKEN, 2-1, Hirosawa, Wako, Saitama 351-0198, Japan Department of Mechanical Engineering, Faculty of Engineering Science, Kansai University, 3-3-35, Yamate-cho, Suita, Osaka 564-8680, Japan
Shintaro Komatani
Affiliation:
Horiba, Ltd., 2, Miyanohigashi, Kisshoin, Minami-ku, Kyoto 601-8510, Japan
Sumito Ohzawa
Affiliation:
Horiba, Ltd., 2, Miyanohigashi, Kisshoin, Minami-ku, Kyoto 601-8510, Japan
Yoshimichi Sato
Affiliation:
Horiba, Ltd., 2, Miyanohigashi, Kisshoin, Minami-ku, Kyoto 601-8510, Japan
Daisuke Matsunaga
Affiliation:
Horiba, Ltd., 2, Miyanohigashi, Kisshoin, Minami-ku, Kyoto 601-8510, Japan
Ryutaro Himeno
Affiliation:
Biomechanical Simulation Research Team, RIKEN, Wako, Saitama 351-0198, Japan
Toshiro Higuchi
Affiliation:
Biomechanical Simulation Research Team, RIKEN, Wako, Saitama 351-0198, Japan Department of Precision Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
Akitake Makinouchi
Affiliation:
Division of Human Mechanical Systems and Design, Graduate School of Engineering, Hokkaido University, N13 W8, Kita-ku, Sapporo 060-8628, Japan VCAD System Research Program, RIKEN, 2-1, Hirosawa, Wako, Saitama 351-0198, Japan
*
Corresponding author. E-mail: hyokota@riken.jp
Get access

Abstract

The elemental composition and microscopic-level shape of inclusions inside industrial materials are considered important factors in fracture analytical studies. In this work, a three-dimensional (3D) microscopic elemental analysis system based on a serial sectioning technique was developed to observe the internal structure of such materials. This 3D elemental mapping system included an X-ray fluorescence analyzer and a high-precision milling machine. Control signals for the X-ray observation process were automatically sent from a data I/O system synchronized with the precision positioning on the milling machine. Composite specimens were used to confirm the resolution and the accuracy of 3D models generated from this system. Each of the two specimens was composed of three metal wires of 0.5 mm diameter braided into a single twisted wire that was placed inside a metal pipe; the pipe was then filled with either epoxy resin or Sn. The milling machine was used to create a mirror-finish cross-sectional surface on these specimens, and elemental analyses were performed. The twisted wire structure was clearly observed in the resulting 3D models. This system enables automated investigation of the 3D internal structure of materials as well as the identification of their elemental components.

Type
Material Applications
Copyright
Copyright © Microscopy Society of America 2011

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Alkemper, J. & Voorhees, P.W. (2001). Quantitative serial sectioning analysis. J Microsc 201(3), 388394.CrossRefGoogle ScholarPubMed
Baruchel, J., Buffiere, J., Cloetens, P., Michiel, M.D., Ferrie, E., Ludwig, W., Maire, E. & Salvo, L. (2006). Advances in synchrotron radiation microtomography. Scripta Mater 55(1), 4146.CrossRefGoogle Scholar
Dudek, M.A. & Chawla, N. (2008). Three-dimensional (3D) microstructure visualization of LaSn3 intermetallics in a novel Sn-rich rare-earth-containing solder. Mater Charact 59(9), 13641368.CrossRefGoogle Scholar
Fujisaki, K., Yokota, H., Furushiro, N., Yamagata, Y., Taniguchi, T., Himeno, R., Makinouchi, A. & Higuchi, T. (2009). Development of ultra-fine-grain binderless cBN tool for precision cutting of ferrous materials. J Mater Proc Technol 209, 56465652.CrossRefGoogle Scholar
Fujisaki, K., Yokota, H., Nakatsuchi, H., Yamagata, Y., Nishikawa, T., Udagawa, T. & Makinouchi, A. (2010). Observation of three-dimensional internal structure of steel materials by means of serial sectioning with ultrasonic elliptical vibration cutting. J Microsc 237(1), 8995.CrossRefGoogle ScholarPubMed
Furushiro, N., Yokota, H., Fujisaki, K., Yamagata, Y., Kokubo, M., Himeno, R., Makinouchi, A. & Higuchi, T. (2008). Three-dimensional internal information acquisition system based on consecutive precision machining and cross-sectional observation—Development of the system and its applications. Proceedings of ASPE 2008 Annual Meeting, pp. 180183. Raleigh, NC: American Society for Precision Engineering.Google Scholar
Khor, K., Buffiere, J., Ludwig, W. & Sinclair, I. (2006). High resolution X-ray tomography of micromechanisms of fatigue crack closure. Scripta Mater 55(1), 4750.CrossRefGoogle Scholar
Lauridsen, E.M., Schmidt, S., Nielsen, S.F., Margulies, L., Poulsen, H.F. & Juul Jensen, D. (2006). Non-destructive characterization of recrystallization kinetics using three-dimensional X-ray diffraction microscopy, Scripta Mater 55(1), 5156.CrossRefGoogle Scholar
Moriwaki, T. & Shamoto, E. (1995). Ultrasonic elliptical vibration cutting. CIRP Ann-Manuf Techn 44(1), 3134.CrossRefGoogle Scholar
Ohzawa, S., Komatani, S. & Obori, K. (2004). High intensity monocapillary X-ray guide tube with 10 micrometer spatial resolution for analytical X-ray microscope. Spectrochim Acta B 59(8), 12951299.CrossRefGoogle Scholar
Paul, E., Evans, C.J., Mangamelli, A., McGlauflin, M.L. & Polvani, R.S. (1996). Chemical aspects of tool wear in single point diamond turning. Precis Eng 18, 419.CrossRefGoogle Scholar
Schaffer, M., Wagner, J., Schaffer, B., Schmied, M. & Mulders, H. (2007). Automated three-dimensional X-ray analysis using a dual-beam FIB. Ultramicroscopy 107(8), 587597.CrossRefGoogle ScholarPubMed
Shamoto, E. & Moriwaki, T. (1999). Ultrasonicprecision diamond cutting of hardened steel by applying ultrasonic elliptical vibration cutting. Ann CIRP 48, 441444.CrossRefGoogle Scholar
Sidhu, R.S. & Chawla, N. (2004). Three-dimensional microstructure characterization of Ag3Sn intermetallics in Sn-rich solder by serial sectioning, Mater Charact 52(3), 225230.CrossRefGoogle Scholar
Spowart, J.E. (2006). Automated serial sectioning for 3-D analysis of microstructures. Scripta Mater 55, 510.CrossRefGoogle Scholar
Yokota, H., Kawaguchi, R., Nakamura, S., Makinouchi, A., Higuchi, T. & Yabe, Y. (2001). 3-dimensional digitizing for the biological sample using a 3-dimensional internal structure microscope. Proc. 2001 Bioengineering Conference ASME, Vol. 50, pp. 217218. New York: American Society of Mechanical Engineers.Google Scholar
Yokota, H., Nakamura, S., Kawaguchi, R., Makinouchi, A., Yabe, H. & Higuchi, T. (2002). Destructed imaging of biological sample using a 3 dimension internal structure microscope. Med Imaging Technol 20(6), 660665 (in Japanese).Google Scholar
Zhang, H., Toda, H., Qu, P.C., Sakaguchi, Y., Kobayashi, M., Uesugi, K. & Suzuki, Y. (2009). Three-dimensional fatigue crack growth behavior in an aluminum alloy investigated with in situ high-resolution synchrotron X-ray microtomography. Acta Mater 57(11), 32873300.CrossRefGoogle Scholar