Hostname: page-component-78c5997874-94fs2 Total loading time: 0 Render date: 2024-11-11T00:30:11.804Z Has data issue: false hasContentIssue false

Prehospital External Aortic Compression for Temporizing Exsanguinating Sub-Diaphragmatic Hemorrhage – A Promising Technique, but with Challenges: Four Illustrative Cases, Including Two Survivors

Published online by Cambridge University Press:  13 January 2020

Bruce Richard Paix*
Affiliation:
SAAS MedSTAR, South Australian Ambulance Service Emergency Medical Retrieval Service, Adelaide, South Australia, Australia
David John Tingey
Affiliation:
Rescue, Retrieval, and Aviation Services, South Australian Ambulance Service, Adelaide, South Australia, Australia
Grant Copley
Affiliation:
Rescue, Retrieval, and Aviation Services, South Australian Ambulance Service, Adelaide, South Australia, Australia
Matthew Casson
Affiliation:
SAAS MedSTAR, South Australian Ambulance Service Emergency Medical Retrieval Service, Adelaide, South Australia, Australia
Damien Shoolbread
Affiliation:
SAAS MedSTAR, South Australian Ambulance Service Emergency Medical Retrieval Service, Adelaide, South Australia, Australia
Hari Davuluru
Affiliation:
SAAS MedSTAR, South Australian Ambulance Service Emergency Medical Retrieval Service, Adelaide, South Australia, Australia
James Doube
Affiliation:
SAAS MedSTAR, South Australian Ambulance Service Emergency Medical Retrieval Service, Adelaide, South Australia, Australia
Wade Emmerton
Affiliation:
SAAS MedSTAR, South Australian Ambulance Service Emergency Medical Retrieval Service, Adelaide, South Australia, Australia
Ryan Kennedy
Affiliation:
Rescue, Retrieval, and Aviation Services, South Australian Ambulance Service, Adelaide, South Australia, Australia
*
Correspondence: Bruce Paix, MBBS, FANZCA, 26 Smith Rd, Echunga, 5153Australia, E-mail: flyingdoc@bigpond.com

Abstract

External aortic compression (EAC) has long been used to control exsanguinating post-partum hemorrhage, but it has only recently been described in the prehospital trauma setting. This paper reports four cases where manual EAC was used during transport to manage life-threatening bleeding, twice from stab wounds, once from ruptured ectopic pregnancy, and once from severe lower-limb trauma. It showed that EAC has life-saving potential in the prehospital setting, but that safety and efficacy during transport requires the use of a hands-free compression device, such as an aortic tourniquet.

Type
Case Report
Copyright
© World Association for Disaster and Emergency Medicine 2020

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Riley, D, Burgess, R.External abdominal aortic compression: a study of a resuscitation maneuver for postpartum hemorrhage. Anaesth Intensive Care. 1994;22(5):571575.CrossRefGoogle Scholar
Keogh, J, Tsokos, N.Aortic compression in massive postpartum hemorrhage – an old but lifesaving technique. Aust NZ J Obstet Gynaecol. 1997;37(2):237238.CrossRefGoogle ScholarPubMed
Soltan, MH, Faragullah, MF, Mosabah, MH, Al-Adawy, AR.External aortic compression device: the first aid for postpartum hemorrhage control. J Obstet Gynecol Res. 2009;35(3):453458.CrossRefGoogle ScholarPubMed
Douma, M, Smith, KE, Brindley, PG.Temporization of penetrating abdomino-pelvic trauma with manual external aortic compression: a novel case report. Ann Emerg Med. 2014;64(1):7982.CrossRefGoogle Scholar
Blaivas, M, Shiver, S, Lyon, M, Adhikari, S.Control of hemorrhage in critical femoral or inguinal penetrating wounds-an ultrasound evaluation. Prehosp Disaster Med. 2006;21(6):379382.CrossRefGoogle ScholarPubMed
Douma, M, Brindley, PG.Abdominal aortic and iliac artery compression following penetrating trauma: a study of feasibility. Prehosp Disaster Med. 2014;29(3):299302.CrossRefGoogle Scholar
Douma, MJ, O’Dochartaigh, D, Brindley, PG.Optimization of indirect pressure in order to temporize life-threatening hemorrhage: a simulation study. Injury. 2016;(47):19031907.CrossRefGoogle ScholarPubMed
FIGO Safe Motherhood and Newborn Health (SMNH) Committee. Prevention and treatment of postpartum hemorrhage in low-resource settings. Int J Gynecol Obstet. 2012;117(2):108118.CrossRefGoogle Scholar
Kin, N, Hayashida, M, Chang, K, et al.External manual compression of the abdominal aorta to control hemorrhage from a ruptured aneurysm. J Anesth. 2002;16(2):164166.CrossRefGoogle ScholarPubMed
Douma, MJ, O’Dochartaigh, D, Brindley, PG.Bi-manual proximal external aortic compression after major abdominal-pelvic trauma and during ambulance transfer: a simulation study. Injury. 2017;48(1):2631.CrossRefGoogle ScholarPubMed
Lyon, M, Shriver, SA, Greenfield, EM, et al.Use of a novel abdominal aortic tourniquet to reduce or eliminate flow in the common femoral artery in human subjects. J Trauma Acute Care Surg. 2012;73(2 Suppl 1):S103105CrossRefGoogle ScholarPubMed
Taylor, DM, Coleman, M, Parker, PJ.The evaluation of an abdominal aortic tourniquet for the control of pelvic and lower limb hemorrhage. Mil Med. 2013;178(11);11961201.CrossRefGoogle ScholarPubMed
Biffl, WL, Fox, CJ, Moore, EE.The role of REBOA in the control of exsanguinating torso hemorrhage. J Trauma Acute Care Surg. 2015;78(5):10541058.CrossRefGoogle ScholarPubMed
Kheirabadi, BS, Terrazas, IB, Miranda, N, et al.Long-term consequences of abdominal aortic and junctional tourniquet for hemorrhage control. J Surg Res. 2018;231:99108.CrossRefGoogle ScholarPubMed