Abstract

Introduction:

Circumstances surrounding the prehospital management of trauma patients may mask clinical signs of inadequate oxygenation. Pulse oximetry (PO) may influence airway management prior to helicopter transport by helping to identify patients with occult hypoxemia.

Methods:

Patients were enrolled in a prospective study. Initially, the flight physician clinically decided how best to manage the patient's airway prior to helicopter transport. The patient's oxygenation saturation (O2at), was determined by PO. Then, the physician reassessed the initial airway management decision based on clinical assessment and knowledge of the O2Sat. All patients had an arterial blood gas (ABG) measurement taken after completion of transport.

Results:

Sixty patients were enrolled. Knowledge of the O2Sat, as determined by pulse oximetry, did not influence airway management. No patients with occult hypoxemia were identified.

Conclusion:

The use of PO in the initial evaluation of trauma patients prior to helicopter transport did not influence the flight physician's initial management of the airway.

Type
Brief Report
Copyright
Copyright © World Association for Disaster and Emergency Medicine 1992

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Mattox, KL, Moore, EE, Feliciano, DV (eds): Trauma. Norwalk, Conn.: Appleton and Lange, 1988, pp 127128.Google Scholar
2. Yelderman, M, New, W: Evaluation of pulse oximetry. Anesthesiology 1983:59:349352.Google Scholar
3. Cohen, DE, Dowries, JJ, Raphaely, RC: What difference does pulse oximetry make? Anesthesiology 1988;68:181183.Google Scholar
4. Jones, J, Heiseiman, D, Cannon, L, Gradisek, R: Continuous emergency department monitoring of arterial saturation in adult patients with respiratory distress. Ann Emerg Med 1988; 17:463468.CrossRefGoogle ScholarPubMed
5. McGuire, TJ, Pointer, JE: Evaluation of a pulse oximeter in the prehospital setting. Ann Emerg Med 1988;17:10581062.CrossRefGoogle ScholarPubMed
6. Silverston, P: Pulse oximetry at the roadside: A study of pulse oximetry in immediate care. Br Med J 1989:298:711713.Google Scholar