We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Stereotactic-fractionated radiotherapy and radiosurgery (RS) for benign and malignant intracranial lesions relies on a very high degree of accuracy in dose alignment due to the ablative dose delivered, and therefore requires a high-precision image guidance modality. The aim of this review is to investigate the localisation and verification accuracy performance of ExacTrac (ET) and Novalis Tx System.
Materials and methods
A systematic review of the database Science Direct was carried out using search terms ‘stereotactic radiotherapy (SRT)’ and ‘ET’. All articles before 2000 were excluded. Only articles that involved intracranial lesions, with the exception of one article, were included in the final review.
Results
Results from gold standard Hidden Target Tests and patient data show that patient position can be reproduced within 1·0 mm with the use of ET imaging. In addition, the 6 degrees of freedom algorithm function of ET allows for better translational accuracy as well optimal positioning when rotations are corrected for. Studies showed excellent correlation (p<0·01) between bony ET images and cone beam computed tomography (CBCT) soft tissue registration, evidencing the safe reliance of bony anatomy for image guidance via ET. Shifts were found to be comparable between CBCT and ET.
Conclusion
There is the need for regular calibration to prevent systematic errors and potential geographic miss. However, due to ET’s additional benefits, including reduced concomitant dose and faster imaging time, ET is the superior image guidance modality for RS/SRT in the treatment of intracranial lesions.