We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Pharyngocutaneous fistulae are dreaded complications following total laryngectomy. This paper presents our experience using 3–5 ml gastrografin to detect pharyngeal leaks following total laryngectomy, and compares post-operative videofluoroscopy with clinical follow-up findings in the detection of pharyngocutaneous fistulae.
Methods
A retrospective case–control study was conducted of total laryngectomy patients. The control group (n = 85) was assessed clinically for development of pharyngocutaneous fistulae, while the study group (n = 52) underwent small-volume (3–5 ml) post-operative gastrografin videofluoroscopy.
Results
In the control group, 24 of 85 patients (28 per cent) developed pharyngocutaneous fistulae, with 6 requiring surgical correction. In the study group, 24 of 52 patients (46 per cent) had videofluoroscopy-detected pharyngeal leaks; 4 patients (8 per cent) developed pharyngocutaneous fistulae, but all cases resolved following non-surgical management. Patients who underwent videofluoroscopy had a significantly lower risk of developing pharyngocutaneous fistulae; sensitivity and specificity in the detection of pharyngocutaneous fistulae were 58 per cent and 100 per cent respectively.
Conclusion
Small-volume gastrografin videofluoroscopy reliably identified small pharyngeal leaks. Routine use in total laryngectomy combined with withholding feeds in cases of early leaks may prevent the development of pharyngocutaneous fistulae.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.