We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
This study aimed to compare neural response telemetry and impedance between the round window and cochleostomy approaches for cochlear implantation.
Methods
In this case–control study, 64 patients aged less than 3.5 years underwent cochlear implantation via the round window or cochleostomy approach. Post-operative neural response telemetry and impedance were measured.
Results
The impedance measurements at electrodes 1, 11 and 22 showed no significant differences between the two groups three months after implantation (p = 0.90, p = 0.08 and p = 0.37, respectively). Similar results were observed six months after implantation (p = 0.71, p = 0.65 and p = 0.70, respectively). There was no significant difference in neural response telemetry between the two groups after three months. The neural response telemetry of electrode 1 in the cochleostomy group (171.26 ± 19.81 μV) was significantly higher in comparison with that of electrode 1 in the round window group (161.97 ± 12.71 μV) after six months (p = 0.03). The neural response telemetry values for electrodes 11 and 22 did not show any significant difference after six months (p = 0.14 and p = 0.48, respectively).
Conclusion
Both approaches provide equal stimulation of the cochlear nerve and impedance.
Brown-Vialetto-Van Laere syndrome, a rare disorder associated with motor, sensory and cranial nerve neuropathy, is caused by mutations in riboflavin transporter genes SLC52A2 and SLC52A3. Hearing loss is a characteristic feature of Brown-Vialetto-Van Laere syndrome and has been shown in recent studies to be characterised by auditory neuropathy spectrum disorder.
Method
This study reports the detailed audiovestibular profiles of four cases of Brown-Vialetto-Van Laere syndrome with SLC52A2 and SLC52A3 mutations. All of these patients had auditory neuropathy spectrum disorder.
Results
There was significant heterogeneity in vestibular function and in the benefit gained from cochlear implantation. The audiological response to riboflavin therapy was also variable, in contrast to generalised improvement in motor function.
Conclusion
We suggest that comprehensive testing of vestibular function should be conducted in Brown-Vialetto-Van Laere syndrome, in addition to serial behavioural audiometry as part of the systematic examination of the effects of riboflavin.
Vertigo and dizziness are frequent symptoms in patients at out-patient services. An accurate diagnosis for vertigo or dizziness is essential for symptom relief; however, it is often challenging. This study aimed to identify differences in diagnoses between primary-care physicians and specialised neurotologists.
Method
In total, 217 patients were enrolled. To compare diagnoses, data was collected from the reference letters of primary-care physicians, medical questionnaires completed by patients and medical records.
Results
In total, 62.2 per cent and 29.5 per cent of the patients were referred by otorhinolaryngologists and internists, respectively. The cause of vertigo or dizziness and diagnosis was missing in 47.0 per cent of the reference letters. In addition, 67.3 per cent of the diagnoses by previous physicians differed from those reported by specialised neurotologists.
Conclusion
To ensure patient satisfaction and high quality of life, an accurate diagnosis for vertigo or dizziness is required; therefore, methods or materials to improve the diagnostic accuracy are needed.
Mastoidectomy is considered an aerosol-generating procedure. This study examined the effect of wearing personal protective equipment on the view achieved using the operating microscope.
Methods
ENT surgeons assessed the area of a calibrated target visible through an operating microscope whilst wearing a range of personal protective equipment, with prescription glasses when required. The distance between the surgeon's eye and the microscope was measured in each personal protective equipment condition.
Results
Eleven surgeons participated. The distance from the eye to the microscope inversely correlated with the diameter and area visible (p < 0.001). The median area visible while wearing the filtering facepiece code 3 mask and full-face visor was 4 per cent (range, 4–16 per cent).
Conclusion
The full-face visor is incompatible with the operating microscope. Solutions offering adequate eye protection for aerosol-generating procedures that require the microscope, including mastoidectomy, are urgently needed. Low-profile safety goggles should have a working distance of less than 20 mm and be compatible with prescription lenses.
To ascertain the distribution of Ménière's disease phenotype subgroups in a US-based cohort, based on a recently introduced classification scheme utilising a Spanish and Portuguese cohort.
Methods
A retrospective, cross-sectional, single-institutional chart review was conducted. The electronic medical records of Ménière's disease patients were identified using International Classification of Diseases codes at a tertiary referral centre and reviewed to extract subgroup-defining features. Patients with definite Ménière's disease as per American Academy of Otolaryngology–Head and Neck Surgery criteria were categorised into one of five subgroups, for unilateral and bilateral Ménière's disease.
Results
Eighty-one patients with definite Ménière's disease were identified. Seventy-two cases of unilateral Ménière's disease were observed: 52.8 per cent were type 1, 20.8 per cent were type 2, 4.2 per cent were type 3, 18.1 per cent were type 4, and 4.2 per cent were type 5. This cohort differed significantly in distribution to a comparison Mediterranean cohort (p < 0.01). Nine cases of bilateral Ménière's disease were observed.
Conclusion
The distribution of unilateral Ménière's disease subtypes in this US population was different from that observed in a European population.
To determine the effectiveness of vestibular rehabilitation using the Wii Fit balance platform, in adults with dizziness.
Methods:
A single-site prospective clinical trial was conducted in a university hospital in the UK. Forty patients with dizziness, who would normally be candidates for vestibular rehabilitation, were identified and considered as potential participants. Participants were randomised into either the treatment group (the Wii Fit group) or the control group (standard customised vestibular rehabilitation protocol). Participants were assessed over a 16-week period using several balance and quality of life questionnaires.
Results:
Both exercise regimes resulted in a reduction of dizziness and an improvement in quality of life scores over time, but no statistically significant difference between the two interventions was identified.
Conclusion:
This pilot study demonstrated that use of the Wii Fit balance platform resulted in a statistically significant improvement in balance function and quality of life. Furthermore, outcomes were comparable to a similar group of individuals following a standard customised vestibular rehabilitation protocol. The study provides useful information to inform the design and execution of a larger clinical trial.