We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
There has been a recent move in psychiatry towards the use of electronic discharge (e-discharge) summaries in an effort to improve the efficiency of communication between primary and secondary care, but there are little data on how this affects the quality of information exchanged.
Objective
To evaluate the quality of psychiatric discharge summaries before and after the introduction of the e-discharge summary system.
Methods
A retrospective analysis of 50 dictated discharge summaries from 1 January to 1 July 2010 and of 50 e-discharge summaries from 1 January to 1 July 2012, evaluating for the inclusion of 15 key items of clinical information.
Results
The average total score of the dictated summaries (mean=9.5, s.d.=2.0) was significantly higher (p<0.001) than the e-discharge summaries (mean=6.7, s.d.=1.8). There were statistically significant differences in five of the standards: findings of physical examination (p<0.001), ICD-10 code (p<0.001), forensic history (p<0.001), alcohol history (p<0.001) and drug history (p<0.001).
Conclusion
Our results revealed a decline in the quality of discharge summaries following the introduction of an electronic system. The reasons for this are unclear and require further analysis. Specific suggestions will depend on the local need, but include improvements in software design and layout as well as better education and training.