We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Desperation for cure led to 19th century invention-- electrotherapeutic devices; replete with hyperbolic claims of cure-all, perceived ineffectiveness, and potential harm rendered the modality as quackery but were used in early brain stimulation, melancholia treatment, and cortex mapping. Here, antique devices are restored, and their electrophysiological qualities ascertained.
Objectives
Determine the comparative capabilities of these devices in delivering electrostimulation and compare with modern standards to understand possible electrophysiological sequelae.
Methods
Devices known as “medical batteries” were analyzed. Power delivery utilized a “voltaic battery”, simple circuit, and a conductor wrapped around an iron core. When the circuit is energized, the core is magnetized by direct current of the battery which induces an alternating current that electrifies probes used on the body. Due to their marked age, a common 9-volt battery was exchanged for the corrosive dry cell paste batteries. Electrical parameters were then measured.
Results
Table 1
Device
Frequency (Hz)
Resistance (Ohms)
Max Output (Amps)
Min Output (Amps)
Max Output (Volts)
Min Output (Volts)
Voltampa
2k – 12K
60
0.66
0.33
60V
20V
J.H. Bunnell & Co.’s No. 4 D.D.
7k-10k
50
6
0.4
300V
20V
Schall & Son (London)b
300-1200
40
10.5
2.75
420V
110V
Conclusions
Devices for electrotherapeutics ranged from anemic vibrations to dangerous tetany inducing shocks. Measuring the capabilities of these devices shows the robust yields possible if the original higher capacity batteries were utilized. The reality is, cure or not, the devices were surprisingly potent. It is interesting that, albeit unrefined, efficacious doses were available before modern electrification.