Hostname: page-component-cd9895bd7-gvvz8 Total loading time: 0 Render date: 2024-12-27T07:00:29.009Z Has data issue: false hasContentIssue false

Aortic regurgitation after closure of ventricular septal defect by transcatheter device: the long-term complication

Published online by Cambridge University Press:  27 February 2020

Yuehu Han
Affiliation:
Department of Cardiovascular Surgery, Xijing Hospital, Fourth Military Medical University, Xi’an, China
Hongling Li
Affiliation:
Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, Xi’an, China
Hailong Zhu
Affiliation:
Department of Cardiovascular Surgery, Xijing Hospital, Fourth Military Medical University, Xi’an, China
Guocheng Sun
Affiliation:
Department of Cardiovascular Surgery, Xijing Hospital, Fourth Military Medical University, Xi’an, China
Qiang Yin
Affiliation:
Department of Cardiovascular Surgery, Xijing Hospital, Fourth Military Medical University, Xi’an, China
Chunhu Gu*
Affiliation:
Department of Cardiovascular Surgery, Xijing Hospital, Fourth Military Medical University, Xi’an, China
*
Author for correspondence: Chunhu Gu, Department of Cardiovascular Surgery, Xijing Hospital, Fourth Military Medical University, Xi’an, China. Tel: +18629267464; E-mail: felix1918@163.com

Abstract

Ventricular septal defect is the most common type of CHD, and transcatheter ventricular septal defect closure has been shown to be an alternative to surgical closure with acceptable mortality and morbidity as well as encouraging results. Short-term and mid-term follow-ups have indicated the safety and efficacy of transcatheter closure, but long-term follow-up results were rare. In this report, we first found that aortic regurgitation occurred in patients 9–12 years following transcatheter closure and regurgitation were gradually increased. The findings indicate that the long-term outcome of transcatheter closure of ventricular septal defect may not be as satisfied as expected.

Type
Brief Report
Copyright
© The Author(s), 2020. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Lim, DS, Forbes, TJ, Rothman, A, Lock, JE, Landzberg, MJTranscatheter closure of high-risk muscular ventricular septal defects with the CardioSEAL occluder: initial report from the CardioSEAL VSD registry. Catheter Cardiovasc Interv. 2007; 70: 740741.CrossRefGoogle ScholarPubMed
Carminati, M, Butera, G, Chessa, M, et al.Transcatheter closure of congenital ventricular septal defects: results of the European Registry. Eur Heart J. 2007; 28: 23612368.CrossRefGoogle ScholarPubMed
Butera, G, Carminati, M, Chessa, M, et al.Percutaneous closure of ventricular septal defects in children aged <12: early and mid-term results. Eur Heart J. 2006; 27: 28892895.CrossRefGoogle ScholarPubMed
Xunmin, C, Shisen, J, Jianbin, G, Haidong, W, Lijun, WComparison of results and complications of surgical and Amplatzer device closure of perimembranous ventricular septal defects. Int J Cardiol. 2007; 120: 2831.CrossRefGoogle ScholarPubMed
Wang, L, Cao, S, Li, J, et al. Transcatheter closure of congenital perimembranous ventricular septal defect in children using symmetric occluders: an 8-year multiinstitutional experience. Ann Thorac Surg. 2012; 94: 592598.CrossRefGoogle ScholarPubMed
Yang, J, Yang, L, Yu, S, et al.Transcatheter versus surgical closure of perimembranous ventricular septal defects in children: a randomized controlled trial. J Am Coll Cardiol. 2014; 63: 11591168.CrossRefGoogle ScholarPubMed
Zheng, Q, Zhao, Z, Zuo, J, et al.A comparative study: early results and complications of percutaneous and surgical closure of ventricular septal defect. Cardiology. 2009; 114: 238243.CrossRefGoogle ScholarPubMed
Yang, J, Yang, L, Wan, Y. Transcatheter device closure of perimembranous ventricular septal defects: mid-term outcomes. Eur Heart J. 2010; 31: 22382245.CrossRefGoogle ScholarPubMed
Pamukcu, O, Narin, N, Baykan, A, Sunkak, S, Tasci, O, Uzum, K. Midterm results of percutaneous ventricular septal defect closure with Amplatzer Duct Occluder-II in children. Cardiol Young. 2017; 27: 17261731.CrossRefGoogle Scholar
Butera, G, Chessa, M, Carminati, M. Percutaneous closure of ventricular septal defects. Cardiol Young. 2007; 17: 243253.CrossRefGoogle ScholarPubMed