We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The purpose of this study was to evaluate the safety and efficacy of the ASDOS-tech-nique (Sulzer-Osypka GmbH, Germany) for transcatheter closure of atrial septal defects within the oval fossa.
Background
Although several attempts have been made to occlude defects within the oval fossa by transcatheter techniques, none of these has gained general acceptance.
Methods
Patients with a defect in the oval fossa measuring equal to or less than 20 mm diameter, with a residual septal rim of 5mm or greater, body weight greater than 10 kg, with clinical indications for surgical closure were considered for transcatheter closure. Follow-up investigations were performed at discharge, after 1, 3, 6 and 9 months, as well as after 1 and 2 years.
Results
Of 78 patients considered for closure, a device was inserted in 41 patients (53%), with success being achieved in 40 patients (98%). The ages ranged from 1.1 to 15 years (7.8 ± 1.92 years), the ’stretched’ diameter of the defect from 10 to 20 mm (14.7 ± 2.60 mm), and the diameters of the inserted devices from 25 to 45 mm (33.2 ± 5.43 mm). Transient impairment of atrioventricular conduction occured in 4 patients. During the follow-up of 23.0 ± 5.6 months elective surgical closure of a residual shunt was performed 26 months after insertion of the devcie in one patient. None of the other patients required surgery, hospitalisation or medical treatment, and none is requiring further treatment of the defect within the oval fossa. Fracture of one arm of the device occurred in 4 patients, but the fractured arms are in an unchanged and stable position after a period of at least 19 months.
Conclusions
Our medium-term data show that transcatheter closure in children of defects within the oval fossa can be performed with a high efficacy and safety using the ASDOS-device.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.