We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
To define the utility of transesophageal echocardiography in predicting the likelihood of a successful procedure and residual shunting in patients undergoing transcatheter closure of defects within the oval fossa using the CardioSEAL® device.
Background
Transesophageal echocardiography is used to monitor transcatheter closure of interatrial defects within the the oval fossa, but predictors of successful closure and residual shunting have yet to be determined.
Methods
We reviewed transesophageal echocardiograms obtained from 26 consecutive patients undergoing attempted transcatheter closure of interatrial defects within the oval fossa between January, 1997 and May, 1998. Assessment of the atrial septum, the septal defect, and the rims of the oval fossa bordering the defect was performed in 3 planes: longitudinal, 4- chamber, and basal short-axis.
Results
Closure proved successful in 24 patients (92%). The defect was significantly larger, and the anterosuperior rim of the defect smaller, in the 2 patients in whom occlusion was not successful. Residual shunting 24 hrs after closure was detected in 14 patients. Significant predictors of leakage included smaller posterior and superior rims, a larger shunt prior to closure, and herniation of a one left atrial arm of the device into the right atrium. In all cases, the sites of leakage were the superior rim of the defect at the superior cavo-atrial junction, and the anterosuperior rim behind the aortic root. Herniation of a left atrial arm into the right atrium was seen in 7 patients (29%). In all, it was the anterosuperior arm which herniated Doppler color flow was suboptimal in detecting residual leaks, and was enhanced substantially with the use of contrast echocardiography.
Conclusions
Transesophageal echocardiography allows excellent assessment of the oval fossa and deficiencies of its floor in all of their dimensions. It is an important tool for guiding the deployment of the occlusion device in patients undergoing attempted transcatheter closure of defects within the fossa. Contrast echocardiography should be used for optimal detection of residual shunting.
Recommend this