We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Pulmonary regurgitation is the most common complication in repaired tetralogy of Fallot patients. Severe chronic pulmonary regurgitation can be tolerated for decades, but if not treated, it can progress to symptomatic, irreversible right ventricular dilatation and dysfunction. We investigated clinical associations with pulmonary valve replacement among patients with significative pulmonary regurgitation and how interventional developments can change their management.
Methods:
All adult patients with repaired tetralogy of Fallot who were followed at an adult CHD Clinic at a single centre from 1980 to 2022 were included on their first outpatient visit. Follow-up was estimated from the time of correction surgery until one of the following events occurred first: pulmonary valve replacement, death, loss to follow-up or conclusion of the study.
Results:
We included 221 patients (116 males) with a median age of 19 (18–25). At a median age of 33 (10) years old, 114 (51%) patients presented significant pulmonary regurgitation. Among patients with significant pulmonary regurgitation, pulmonary valve replacement was associated with male gender, older age at surgical repair, and longer QRS duration in adulthood. Pulmonary valve replacement was performed in 50 patients, including four transcatheter pulmonary valve implantations, at a median age of 34 (14) years.
Conclusion:
Pulmonary regurgitation affects a large percentage of tetralogy of Fallot adult patients, requiring a long-term clinical and imaging follow-up. Sex, age at surgical repair and longer QRS are associated with the need of PVR among patients with significative pulmonary regurgitation. Clinical practice and current literature support TPVI as the future gold standard intervention.
The purpose of this study is to assess the feasibility, effectivity, and safety of a novel self-expandable valve system, Pulsta® transcatheter heart valve in patients with tetralogy of fallot and severe pulmonary regurgitation after transannular patch repair.
Background:
Severe pulmonary regurgitation after tetralogy of fallot repair is a life-threatening problem and should be treated by pulmonary valve implantation. Although percutaneous pulmonary valve implantation has been ever increasingly used for this purpose, available balloon-expandable valves have limitations and cannot be used by most patients. Pulsta® transcatheter heart valve is a new self-expandable valve system and offers a new solution to be used in patients with different types of native right ventricular outflow tract geometry.
Patients and Methods:
Ten patients with severe regurgitation after tetralogy of fallot repair with a transannular patch have been enrolled in the study according to echocardiographic examination. MRI was used in asymptomatic patients to delineate the indication and the right ventricular outflow tract geometry. Pulsta® transcatheter heart valve implantation was performed in ten patients, and preprocedural, procedure, and 6 months follow-up findings of the patients were evaluated.
Results:
Pulsta® pulmonary valve implantation was performed in ten patients successfully without any severe complications. Valve functions were perfect in six of ten patients, while the others had insignificant regurgitation by echocardiographic examination at the end of 6 months follow-up.
Conclusions:
This study showed that Pulsta® transcatheter heart valve is a feasible, effective, and safe method in the treatment of severe pulmonary regurgitation due to transannular patch repair in patients with tetralogy of fallot.
Assess the acute and short-term haemodynamic impact of transcatheter pulmonary valve implantation on left ventricular systolic and diastolic function stratified by pre-transcatheter pulmonary valve implantation physiology.
Background:
Transcatheter pulmonary valve implantation is a widely available option to treat residual or recurrent pulmonary stenosis and pulmonary insufficiency. Transcatheter pulmonary valve implantation acutely increases pulmonary artery size and diastolic pressure in patients with pulmonary insufficiency and acute pulmonary edema has been reported after transcatheter pulmonary valve implantation, possibly related to acute left ventricular volume loading. However, the impact of transcatheter pulmonary valve implantation on left ventricular diastolic function has not been established.
Methods:
Patients who underwent transcatheter pulmonary valve implantation from 2010 to 2017 at our centre were grouped by indication for transcatheter pulmonary valve implantation as pulmonary stenosis, pulmonary insufficiency, or mixed disease. Separate analysis was performed on those who underwent transcatheter pulmonary valve implantation for pulmonary stenosis versus pulmonary insufficiency or mixed disease. Intracardiac haemodynamics immediately before and after transcatheter pulmonary valve implantation and echocardiographic assessment of left ventricular systolic and diastolic function at baseline, 1-day post transcatheter pulmonary valve implantation, and 1-year post transcatheter pulmonary valve implantation were compared between groups.
Results:
In 102 patients who underwent transcatheter pulmonary valve implantation, the indication was pulmonary stenosis in 29 (28%), pulmonary insufficiency in 28 (29%), and mixed disease in 44 (43%). There were no significant differences in left ventricular systolic or diastolic function between groups at baseline, immediately after transcatheter pulmonary valve implantation, or 1-year post implantation. The mean pulmonary artery wedge pressure increased equally across groups.
Conclusions:
While patients with pulmonary insufficiency likely have acute left ventricular volume loading following transcatheter pulmonary valve implantation, this does not appear to be haemodynamically significant as transcatheter pulmonary valve implantation was not associated with measurable changes in left ventricular systolic or diastolic function acutely or 1-year post implantation.