Hostname: page-component-cd9895bd7-mkpzs Total loading time: 0 Render date: 2024-12-28T12:22:52.434Z Has data issue: false hasContentIssue false

Flow of Newtonian Fluid in Non-Uniform Tubes with Application to Renal Flow: A Numerical Study

Published online by Cambridge University Press:  03 June 2015

P. Muthu*
Affiliation:
Department of Mathematics, National Institute of Technology, Warangal, Warangal 506004, India
Tesfahun Berhane*
Affiliation:
Department of Mathematics, National Institute of Technology, Warangal, Warangal 506004, India
*
Corresponding author. URL: http://www.nitw.ac.in/nitwnew/facultypage.aspx?didno=9&fidno=622 Email: snklpm@rediffmail.com
Get access

Abstract

In this paper, a numerical method employing a finite difference technique is used for an investigation of viscous, incompressible fluid flow in a tube with absorbing wall and slowly varying cross-section. The effect of fluid absorption through permeable wall is accounted by prescribing flux as a function of axial distance. The method is not restricted by the parameters in the problem such as wave number, permeability parameter, amplitude ratio and Reynolds number. The effects of these parameters on the radial velocity and mean pressure drop is studied and the results are presented graphically. Comparison is also made between the results obtained by perturbation method of solution and present approach.

Type
Research Article
Copyright
Copyright © Global-Science Press 2011

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

[1] Macey, R. I., Pressure flow patterns in a cylinder with reabsorbing walls, Bull. Math. Bio-phys., 25 (1963), pp. 19.Google Scholar
[2] Kelman, R. B., A theoretical note on exponential flow in the proximal part of the mammalian nephron, Bull. Math. Biophys., 24 (1962), pp. 3138.Google Scholar
[3] Macey, R. I., Hydrodynamics in renal tubules, Bull. Math. Biophys., 27 (1965), pp. 117124.Google Scholar
[4] Marshall, E. A. and Trowbridge, E. A., Flow of a Newtonian fluid through a permeable tube: the application to the proximal renal tubule, Bull. Math. Bio., 36 (1974), pp. 457476.CrossRefGoogle Scholar
[5] Palatt, P. J., Sackin, H. and Tanner, R., A hydrodynamical model of a permeable tubule, J. Theor. Biol., 44 (1974), pp. 287303.Google Scholar
[6] Radhakrisnamacharya, G., Chandra, P. and Kaimal, M. R., A hydrodynamical study of the flow in renal tubules, Bull. Math. Bio., 43(2) (1981), pp. 151163.Google Scholar
[7] Chandra, P. and Krishna Prasad, J.S.V.R., Low reynolds number flow in tubes of varying cross-section with absorbing walls, J. Math. Phys. Sci., 26(1) (1992), pp. 1936.Google Scholar
[8] Chaturani, P. and Ranganatha, T. R., Flow of Newtonian fluid in non-uniform tubes with variable wall permeability with application to flow in renal tubules, Acta. Mech., 88 (1991), pp. 1126.Google Scholar
[9] Muthu, P. and Berhane, T., Mathematical model of flow in renal tubules, Int. Jr. App. Math. Mech., 6 (20) (2010), pp. 94107.Google Scholar
[10] Takabatake, S. and Ayukawa, K., Numerical study of two-dimensional peristaltic flows, J. Fluid. Mech., 122 (1982), pp. 439465.Google Scholar
[11] Ayukawa, K. and Takabatake, S., Numerical analysis of two-dimensional peristaltic flows, Bull. JSME., 25 (1982), pp. 10611069.Google Scholar
[12] Takabatake, S., Ayukawa, K. and Mori, A., Peristaltic pumping in circular cylinderical tubes: a numerical study of fluid transport and its efficiency, J. Fluid. Mech., 193 (1988), pp. 267283.Google Scholar
[13] Elshehawey, E. F., Elbarbary, E. M. E. and Elgazery, N. S., Effect of inclined magnetic field on magneto fluid flow through a porous medium between two inclined wavy porous plates (numerical study), Appl. Math. Comput., 135 (2003), pp. 85103.Google Scholar