Hostname: page-component-cd9895bd7-gvvz8 Total loading time: 0 Render date: 2024-12-26T22:38:03.819Z Has data issue: false hasContentIssue false

Research in the Quantitative Analysis of Individual Particles by X-Ray Fluorescence Spectrometry

Published online by Cambridge University Press:  06 March 2019

M. Lankosz
Affiliation:
Department of Physics and Nuclear Techniques, Academy of Mining and Metallurgy, al. Mickiewicza 30, Krakow, Poland
B. Holynska
Affiliation:
Department of Physics and Nuclear Techniques, Academy of Mining and Metallurgy, al. Mickiewicza 30, Krakow, Poland
P.A. Pella
Affiliation:
National Institutes of Standards and Technology, Gaithersburg, MD 20899
D.H. Blackburn
Affiliation:
National Institutes of Standards and Technology, Gaithersburg, MD 20899
Get access

Extract

In a previous publication, we compared measurements of the x-ray microfluorescence of calcium and iron from homogeneous spherical glass particles with the results of Monte Carlo simulation. That work was performed to verify a Monte Carlo model developed for the characterization of particle size effects using a polished flat sample of the same composition as a reference standard. The present work extends our comparison to synthetic glass particles containing elements of higher atomic number. We also modified our Monte Carlo model to include simulation of x-ray fluorescence from elements in irregular shaped synthetic particles. In addition, the Compton scattering from spherical and irregular shaped particles was simulated using Monte Carlo and compared with experimental measurements.

Type
I. Mathematical Techniques in X-Ray Spectrometry
Copyright
Copyright © International Centre for Diffraction Data 1992

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Lankosz, M., Holynska, B., and Fella, P. A., Experimental Verification of a Monte Carlo Method for X-Ray Microfluorescence Analysis of Small Particles, accepted for publication in X-Ray Spectrometry (1993).Google Scholar
2. Small, J. A., Heinrieh, K. F. J., Fiori, C. E., Myklebust, E. L., Newbury, D. E., and Dilmore, M. F., The Production and Characterization of Glass Fibers and Spheres for Microanalysis, Scanning Elec. Micros. 1:445 (1978).Google Scholar
3. Pella, P. A. and Feng, L., Fabrication and Selected Applications of a NIST X-ray Microfluorescence Spectrometer, Advances in X-ray Analysis 35B:1063 (1992).Google Scholar
4. Pella, P. A., Feng, L., and Small, J. A., An Analytical Algorithm for Calculation of Spectral Distributions of X-Ray Tubes for Quantitative X-Ray Fluorescence Analysis, X-Ray Spectrometry 14:125 (1985).Google Scholar