In 1931 Peters showed that flow entry conditions had a marked effect on diffuser performance. Later, Winternitz and Ramsay indicated that the pressure recovery coefficient Cp of a conical diffuser might be regarded as a linear function of β(θ/d)i for values of β(θ/d)i up to 0·1. This note draws attention to the fact that diffusers with much larger values of this parameter are of interest and presents some experimental and theoretical results. Work is continuing along the lines indicated.