No CrossRef data available.
Article contents
Effect of dry hydrogen peroxide on Candida auris environmental contamination
Published online by Cambridge University Press: 29 September 2023
Abstract
Background: Candida auris is an emerging pathogen that exhibits broad antimicrobial resistance and causes highly morbid infections. Prolonged survival on surfaces has been demonstrated, and standard disinfectants may not achieve adequate disinfection. Persistent patient colonization and constant environmental recontamination poses an infection risk that may be mitigated by no touch disinfection systems. We evaluated the efficacy of continuous dry hydrogen peroxide (DHP) exposure on C. auris environmental contamination. Methods: The study was conducted in a large tertiary-care center where multiple patients were identified as either infected or colonized with C. auris. DHP-emitting systems were installed in the ventilation systems dedicated to the adult burn intensive care and children’s cardiac intensive care units. Composite surface samples were collected in a sample of patient rooms and shared clinical workspaces among units with current C. auris patients, before and after installation of the DHP system, and from areas with and without exposure to DHP. The samples included “high touch” surfaces near the patient, the general area of the patient room, shared medical equipment for the unit, shared staff work areas, and equipment dedicated to individual staff members (Table 1). Presence of C. auris was determined by polymerase chain reaction (PCR). Association between DHP exposure and C. auris contamination was determined using the Fisher exact test. Results: In the presence of C. auris patients, 5 baseline samples per unit were taken before DHP was installed, and then 5 samples per unit were taken on days 7, 14, and 28 after installation. Prior to initiation of DHP, 7 (70%) of 10 samples were PCR positive for C. auris. After DHP installation, a statistically significant decrease to 5 (16.7%) of 30 samples (P <.05) was observed. In total, 20 samples (5 before installation and 15 after installation) were collected from units without DHP on the same days. At baseline, 2 (40%) of 5 samples were PCR positive for C. auris. During subsequent periods, 4 (27%) 15 samples were positive (P = .66). No adverse effects were reported by patients, visitors, or personnel in association with the operation of the DHP systems. Conclusions: These findings suggest that DHP is effective in reducing surface C. auris contamination in a variety of patient and healthcare worker surfaces.
Disclosures: None
- Type
- Environmental Cleaning
- Information
- Antimicrobial Stewardship & Healthcare Epidemiology , Volume 3 , Issue S2: SHEA Spring 2023 Abstracts , June 2023 , pp. s67 - s68
- Creative Commons
- This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
- Copyright
- © The Author(s), 2023. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America