Hostname: page-component-cd9895bd7-jkksz Total loading time: 0 Render date: 2024-12-26T19:49:08.304Z Has data issue: false hasContentIssue false

Is your ice machine really clean? Uncovering the presence of opportunistic pathogens in hospital ice machines

Published online by Cambridge University Press:  16 May 2022

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Background: Ice is used in healthcare facilities for medical purposes and consumption by the medical staff and the patients, but some studies have revealed significant microbial contamination of ice machines leading to nosocomial outbreaks or pseudooutbreaks and infections by opportunistic pathogens, including the fungi Candida, the bacteria Pseudomonas aeruginosa, and nontuberculous mycobacteria (NTM). Although ice machines are complex devices that are prone to contamination, very little is known about their potential as vectors of infections for populations at risk in hospitals. Only few studies document efficient maintenance regimes, specifically cleaning procedures and microbial indicators that would ensure their safe use. Method: In this prospective study, combined samples of water and ice, and drain biofilm samples were collected from 36 ice and cold-water distribution machines of a recently built hospital, for a total of 72 samples. Physicochemical parameters (total and free chlorine, temperature, etc) were measured in water, and several opportunistic pathogens (ie, Candida spp, P. aeruginosa, NTM) and biological indicators (ie, heterotrophic plate counts (HPCs), total and viable bacteria and enterococci) were monitored in water and ice and biofilm. Culture methods were used for HPCs, Candida spp, P. aeruginosa, and enterococci, and total and viable bacterial populations were estimated using flow cytometry. NTM were monitored by quantitative polymerase chain reaction (qPCR). Results: We observed clear differences between the machines in terms of biological contamination, with frequent detection of NTM and presumed Candida. Thus, NTM were detected in the 36 samples of ice and water with concentrations from 0.5 to 2×104 gene copies/mL. Among the several species of fungi detected in the ice machines, some were identified as C. parapsilosis and C. guilliermondii, which are organisms of concern in healthcare facilities. Factors affecting the level of contamination in ice machines include the location of the machines and water quality (ie, temperature and chlorine residual concentration). Depending on the location in the building and the model of ice machine sampled, the biological indicators measurements indicated more or less significant contamination. No link was established between environmental strains recovered from the machines and clinical infections. Conclusions: Monitoring results showed that ice machines, while subject to few regulations and controls, can be reservoirs of unsuspected opportunistic pathogens that could lead to nosocomial infections of vulnerable patients. Cleaning procedures should be based on the disinfection of resistant opportunistic pathogens, such as Candida and NTM, and the use of general indicators, such as HPCs, should be questioned.

Funding: None

Disclosures: None

Type
Environmental Cleaning
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
© The Author(s), 2022. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America