Article contents
15 Feasibility of Using Wearable Sensors to Detect Agitation in Persons with Dementia
Published online by Cambridge University Press: 12 March 2019
Abstract
Wearable sensors have become increasingly accurate in measuring various aspects of health monitoring in humans. Persons with dementia (PWD) often experience problematic behavioral and psychological symptoms of dementia (BPSD). These behaviors can include kicking, hitting, biting, screaming, pushing and are stressful and dangerous for the PWD as well as for caregivers both formal paid caregivers and informal family caregivers. There are many proven methods to intervene during agitated behavior outburst and the earlier these methods are used the better the results. Such methods include redirection, one-on-one socialization, music therapy, pet assisted therapy, etc. These types of effective methods are preferred over routine or as needed medications to control the behaviors. The medications currently used have well documented adverse side effects, especially in aging adults.
This IRB approved study used a convenience sample of eight PWD who had a history of BPSD in an assisted living facility specializing in the care of PWD. We evaluated the use of off-the-shelf smart watch technology to measure limb movements, vocalizations, heart rate and location in a facility. The research goal was to determine the feasibility of using this technology to accurately measure patient data which in turn will allow clinicians to promptly detect agitation and provide early intervention. Output data from the watch was compared to data recorded by trained observers using the Cohen-Mansfield Agitation Inventory (CMAI). Data was collected in four-hour blocks of time over a two-day period.
All the participants wore the devices without difficulty. Observations were then compared to the information obtained from the smart watch technology. Limb movements and heart rate increases correlated well with observers’ measurements of agitation. True positive measures were greater than 60% (data streams from devices correlated with observations). The voice measures of tone, volume and words used did not correlate well due to background noise in this communal environment.
Data streams did correlate with observations. This technology could be useful in quickly identifying, and potentially anticipate, agitation in PWD. Further research is pending that will fine tune our software developed to measure the data streams and enhance accuracy. Also, improvements are being made in the ability to use voice recognition technology to capture the vocalizations associated with agitation. This technology can be used to quickly identify and prevent escalation of some BPSD by allowing early application of non-pharmacologic methods to treat agitation. Further study will also evaluate the impact this may have on the quality of life for caregivers and PWD.
Funding Acknowledgements: Old Dominion University Office of Research, $2,500
- Type
- Abstracts
- Information
- Copyright
- © Cambridge University Press 2019
- 2
- Cited by