Bacterial contamination of floors and other surfaces in operating rooms: a five-year survey

Published online by Cambridge University Press:  19 October 2009

Asakatsu Suzuki
Affiliation:
Department of Surgical Operation and
Yoshimichi Namba
Affiliation:
Department of Surgical Operation and
Masaji Matsuura
Affiliation:
Department of Anaesthesiology, Nagoya University Hospital, Nagoya, Japan
Akiko Horisawa
Affiliation:
Department of Surgical Operation and
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Bacterial contamination of floors and other surfaces in the operating suite has been investigated by contact impression plates during the past five years. Colony counts of the floors of operating rooms, cleaned with disinfectant, were 3·3 c.f.u./10 cm2; on the floors of semi-clean and dirty areas, cleaned with detergent, colony counts were 44·8 and 71·4 c.f.u./10 cm2 respectively. The highest colony counts of 487·4 c.f.u./10 cm2 were found in the dressing rooms, the floors of which were covered with carpets, cleaned with a vacuum cleaner. Mean bacterial numbers on surfaces of various equipment in operating rooms, cleaned with disinfectant, were 2·8 c.f.u./10 cm2. Bacterial numbers on surfaces decreased markedly from 253·2 to 11·9 c.f.u./10 cm2 following the use of disinfectant. Bacterial species found from various surfaces were mainly coagulase-negative staphylococci, derived from human beings. In the light of these findings the regular use of disinfectant for cleaning of the floors and other surfaces in operating rooms is advisable.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1984

References

Ayliffe, G. A. J., Collins, B. J. & Lowbury, E. J. L. (1966). Cleaning and disinfection of hospital floors. British Medical Journal ii, 442445.CrossRefGoogle Scholar
Ayliffe, G. A. J., Collins, B. J. & Lowbury, E. J. L. (1967). Ward floors and other surfaces as reservoirs of hospital infection. Journal of Hygiene 65, 515536.Google ScholarPubMed
Froud, P. J., Alder, V. G. & Gillespie, W. A. (1966). Contaminated areas in operating theatres. Lancet ii, 961963.CrossRefGoogle Scholar
Hambraeus, A., Benotsson, S. & Laurell, G. (1978 a). Bacterial contamination in a modern operating suite. 3. Importance of floor contamination as a source of airborne bacteria. Journal of Hygiene 80, 169174.CrossRefGoogle Scholar
Hambraeus, A., Benotsson, S. & Laurell, G. (1978 b). Bacterial contamination in a modern operating suite. 2. Effect of a zoning system on contamination of floors and other surfaces. Journal of Hygiene 80, 5767.CrossRefGoogle Scholar
Petersen, N. J., Marshall, J. H. & Collins, D. E. (1973). Why wash walls in hospital isolation rooms? Health Laboratory Science 10, 2327.Google ScholarPubMed
Vesley, D. & Michaelsen, G. S. (1964). Application of a surface sampling technic to the evaluation of bacteriological effectiveness of certain hospital housekeeping procedures. Health Laboratory Science 1, 107113.Google Scholar
Weber, D. O., Gooch, J. J., Wood, W. R., Britt, E. M. & Kraft, R. O. (1976). Influence of operating room surface contamination on surgical wounds. Archives of Surgery 111, 484488.CrossRefGoogle ScholarPubMed
Wypkema, W. & Alder, V. G. (1962). Hospital cross infection and dirty walls. Lancet ii, 10661068.CrossRefGoogle Scholar