Hostname: page-component-cd9895bd7-gxg78 Total loading time: 0 Render date: 2024-12-27T12:05:17.867Z Has data issue: false hasContentIssue false

Cleaning of hospital floors with oiled mops

Published online by Cambridge University Press:  15 May 2009

J. R. Babb
Affiliation:
Medical Research Council Industrial Injuries and Burns Research Unit, Birmingham Accident Hospital
H. A. Lilly
Affiliation:
Medical Research Council Industrial Injuries and Burns Research Unit, Birmingham Accident Hospital
E. J. L. Lowbury
Affiliation:
Medical Research Council Industrial Injuries and Burns Research Unit, Birmingham Accident Hospital
Rights & Permissions [Opens in a new window]

Extract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

A comparison was made of three methods for the removal of dust from a hospital ward floor.

The viable bacterial counts of impression plates from the floor showed a mean reduction of 51 % after cleaning with fresh oiled mops, 40 % after cleaning with a tank model vacuum cleaner and 5 % after sweeping with a broom.

The mean proportions of airborne bacteria, compared with viable counts before cleaning, were 192 % during and 194 % after cleaning with a broom; 128 % during and 103 % after cleaning with an oiled mop, and 82 % during and 48 % after cleaning with a vacuum cleaner. On repeated use the oiled mop dispersed almost as much dust as a broom, but this settled rapidly from the air.

The effects of these cleaning methods on counts of presumptive Staph. aureus on the floor and in the air were similar to those found in counts of total organisms.

We wish to thank Mr M. D. Wilkins for valuable assistance, the Domestic Superintendent and staff and the nursing staff for their co-operation, and Messrs Leeming Brothers Limited for supplies of ‘Kex’ mops and equipment.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1963

References

Barber, M. & Kuper, S. W. A. (1951). Identification of Staph. pyogenes by the phosphatase reaction. J. Path. Bact. 63, 65.CrossRefGoogle Scholar
Bate, J. G. (1961). Bacteriological investigation of exhaust air from hospital vacuum cleaners. Lancet, i, 159.CrossRefGoogle Scholar
Burnham, F. E. (1962). Floor maintenance in hospital wards. Hospital (Lond.), August 1962, p. 543.Google Scholar
Foster, W. D. (1960). Environmental staphylococcal contamination: a study by a new method. Lancet, i, 670.CrossRefGoogle Scholar
Rogers, K. B. (1951). The use of cylinder model vacuum cleaners. J. Hyg., Camb., 49, 497.Google ScholarPubMed
van den Ende, M., Lush, D. & Edward, D. G. ff. (1940). Reduction of dust-borne bacteria by treating floors. Lancet, ii, 133.CrossRefGoogle Scholar