Hostname: page-component-78c5997874-v9fdk Total loading time: 0 Render date: 2024-11-10T14:09:01.882Z Has data issue: false hasContentIssue false

Legionella prevalence and risk of legionellosis in Japanese households

Published online by Cambridge University Press:  07 February 2017

T. KUROKI*
Affiliation:
Department of Microbiology, Kanagawa Prefectural Institute of Public Health, Chigasaki, Kanagawa, Japan
Y. WATANABE
Affiliation:
Department of Microbiology, Kanagawa Prefectural Institute of Public Health, Chigasaki, Kanagawa, Japan
H. TERANISHI
Affiliation:
Department of Regional Hygiene Inspection, Kanagawa Prefectural Institute of Public Health, Chigasaki, Kanagawa, Japan
S. IZUMIYAMA
Affiliation:
Department of Parasitology, National Institute of Infectious Diseases, Shinjuku-ku, Tokyo, Japan
J. AMEMURA-MAEKAWA
Affiliation:
Department of Bacteriology I, National Institute of Infectious Diseases, Shinjuku-ku, Tokyo, Japan
F. KURA
Affiliation:
Department of Bacteriology I, National Institute of Infectious Diseases, Shinjuku-ku, Tokyo, Japan
*
*Author for correspondence: T. Kuroki, Department of Microbiology, Kanagawa Prefectural Institute of Health, 1-3-1 Shimomachiya, Chigasaki, Kanagawa 253-0087, Japan. (Email: kuroki.gcg3@pref.kanagawa.jp)
Rights & Permissions [Opens in a new window]

Summary

This study determined the occurrence of legionellae in private houses for which there were no available data on aquatic environments other than the water supply system. From June 2013 to November 2014, we collected 138 water and 90 swab samples from aquatic environments in 19 houses. Legionella DNA was detected via a loop-mediated isothermal amplification assay in 66 (47·8%) water and 17 (18·9%) swab samples. High Legionella DNA detection rates were observed in water samples from washing machines and aquariums. Legionella spp. was isolated from 9 (6·5%) water and 3 (3·3%) swab samples. Legionella pneumophila SG 1 was detected from the outlet water of a bathtub spout and a bath sponge. Use of amoebic co-culture effectively increased legionellae and Legionella DNA detection rates from all sample types. A logistic regression analysis revealed that the heterotrophic plate count was significantly related to Legionella contamination. Our findings indicate that there is a risk of legionellosis from exposure to Legionella spp. in a variety of aquatic environments in residential houses. Control measures for legionellae in houses should include frequent cleaning and disinfecting to reduce heterotrophic bacteria in water and, where possible, preventing aerosolization from aquatic environments.

Type
Original Papers
Copyright
Copyright © Cambridge University Press 2017 

INTRODUCTION

Legionellae, Gram-negative bacteria found in aquatic environments are causative agents of legionellosis [Reference Mercante and Winchell1]. This disease is acquired by inhalation or aspiration of aerosols containing legionellae from an environmental source. Legionellosis has two distinct forms: Legionnaires’ disease and Pontiac fever [Reference Fields, Benson and Besser2]. Sporadic Legionella infections, rather than outbreak cases, account for most Legionella infections [Reference Atlas3]. A substantial proportion of sporadic cases may be residentially acquired [Reference Straus4], and these infections have been documented worldwide. Several cases of legionellosis linked to home water supplies were previously reported [Reference Stout, Yu and Muraca5, Reference Pedro-Botet, Stout and Yu6].

Previously, approximately 700–900 cases of Legionella infection were reported in Japan each year [7], but in 2014 the number of reported cases increased to 1248 (http://www.nih.go.jp/niid/ja/survei/2085-idwr/ydata/5672-report-ja2014-20.html). Sporadically occurring cases of community-acquired legionellosis accounted for most of these infections [7]. While most cases of Legionella infection are associated with spas in public bath facilities and accommodations [8], some sporadic cases associated with baths involved residential infections [Reference Nagai9].

Control measures for preventing Legionella infection from water supply systems have been reported previously. Chlorination of potable water, increasing water heater temperatures, and limiting exposure to aerosols in private residences were recommended [Reference Straus4]. Regular flushing of showers decreased Legionella to below detectable levels [Reference Makin and Hart10]. Because Legionella requires an appropriate temperature and pH to grow, extreme water temperatures and pH can be used to prevent Legionella proliferation [Reference Wadowsky11].

Despite the occurrence of Legionella in a wide range of aquatic environments, a limited number of studies have analyzed Legionella contamination in the water supply systems of houses [Reference Mathys12], and, to our knowledge, no information on Legionella contamination in other aquatic environments within houses is available. The aim of this study was to investigate residential Legionella contamination. Additionally, the relationship between Legionella contamination and the characteristics of the water samples collected in households, including the number of heterotrophic bacteria, residual-free chlorine concentration, pH, and temperature, was investigated to determine whether these factors could be utilized to prevent the colonization of Legionella in household aquatic environments.

METHODS

Sample collection

Samples were collected from 19 private homes during the period between July 2013 and November 2014. The private homes were selected from those of colleagues of our Institute and associates. House members were asked to collaborate and provide consent for their house samples to be collected and tested for Legionella. Fourteen of the 19 homes, which were located in Kanagawa Prefecture, provided a variety of samples, while the remaining five homes provided only aquarium water samples. These 14 houses consisted of five condominium units and nine single-family houses. All houses studied received chlorinated tap water that met the Japanese water quality standard. The ages of the condominium units and houses ranged from 1 to 30 years old and from 4 to 55 years old, respectively. No members of any of these homes contracted Legionnaires’ disease or Pontiac fever before and during the investigation period.

Overall, 138 water samples (Table 1) and 90 swab samples (Table 2) were analyzed in this study. Water samples (up to 1000 ml) were collected in sterile vessels containing 0·5 g sodium thiosulphate/1000 ml sample water to neutralize residual chlorine. The samples were collected as follows: water samples were taken from the tap outlet of cold water supplies immediately after the valve was opened. Residual water in shower hoses and showerheads or garden hoses in the house yard was collected. To collect a water sample from a washing machine, about 10 liters of tap water from a tap directly connected to the washing machine was added into a drum, the washing machine was run for 10 min, and then 1000 ml of water was collected in a sterile container. Tap water was used for this procedure instead of sterile water to analyze the contamination of washing machines under their normal use conditions. Bath sponges that were used for cleaning bathtubs were squeezed by hand with sterile gloves to collect water samples. The swab samples were taken using a sterile Dacron swab (JCB Industry Limited, Tokyo, Japan) at each sampling site and were each immersed in 1·0 ml of sterilized phosphate-buffered saline (PBS) that had been diluted 50-fold.

Table 1. Household Legionella contamination in water samples

* L. rowbothamii.

L. pneumophila SG1, ST22.

Legionella sp. L-29.

§ L. anisa.

L. busanensis.

**L. sainthelensi was from two samples and L. anisa was from one sample.

†† Not determined. Bath spout is defined as a pipe and liplike projection at the side of a bathtub by which hot water enters the bath.

Table 2. Household Legionella contamination in swab samples

* Legionella sp. L-29.

Legionella sp.

One sample contained the DNA of L. pneumophila ST1966.

§ L. anisa.

A pump to transfer leftover bathwater from a bathtub to a washing machine for laundry.

Physical and chemical analyses

The temperature and pH of water samples were measured on site. The residual-free chlorine concentrations were measured at our laboratory by the DPD (N,N-diethyl-p-phenylenediamine) method using AQUAB AQ-201 (Shibata Scientific Technology, Saitama, Japan) in accordance with the manufacturer's instructions.

Heterotrophic plate count

The number of heterotrophic bacteria was determined by heterotrophic plate count (HPC). Water samples were inoculated with 10-fold serial dilutions. Serially diluted samples (100 µl) were inoculated onto R2A agar plates (BD, Tokyo, Japan), and the colonies were counted after the plates had been incubated at 25 °C for 7 days.

Legionella detection

Water samples (500 ml) were filtered through a 0·2-μm porosity polycarbonate membrane filter (Advantec Toyo Kaisha, Tokyo, Japan). The membranes were then placed in 10 ml of 50-fold-diluted PBS, and any bacteria were dislodged by vortexing. Swab samples were suspended in 5 ml of 50-fold-diluted PBS. The suspension was then subjected to heat treatment at 50 °C for 20 min according to the methods of Kasuga et al. [Reference Kasuga13] followed by acid buffer treatment in HCl–KCl buffer (pH 2·2) for 4 min according to the methods of Bopp et al. [Reference Bopp14]. The samples were subsequently inoculated onto GVPC agar (Oxoid, Hampshire, UK) plates by the spread plate method, and the plates were incubated at 36 °C for at least 7 days. The resulting suspected colonies that were smooth and grayish white or gray–blue–purple were subcultured on BCYE-α plates (Oxoid) and on horse blood agar plates, all of which were incubated at 36 °C for 5 days. The detection limit of the culture method was 100 colony-forming units (CFU)/l. Colonies that grew only on BCYE-α were verified as Legionella by polymerase chain reaction (PCR) with specific primers for the Legionella 5S rRNA gene (Cycleave PCR Legionella Detection Kit, Takara Bio, Shiga, Japan). The sequence type of Legionella pneumophila was determined in accordance with the European Working Group for Legionella Infections Sequence-Based Typing (SBT) protocol (http://www.hpa-bioinformatics.org.uk/legionella/legionella_sbt/php/sbt_homepage.php), as described previously [Reference Gaia15, Reference Ratzow16]. Serotyping was performed using a slide agglutination test with commercial antiserum (Denka Seiken, Tokyo, Japan). Non-L. pneumophila isolates were identified by sequencing the 16S rRNA and mip genes [Reference Ratcliff17, Reference Ratcliff, Buchrieser and Hilbi18]. Obtained sequences of 16S rRNA and mip genes were queried against the DNA Data Bank of Japan (DDBJ) database and the Legionella mip gene sequence database (http://www.hpa-bioinformatics.org.uk/cgi-bin/legionella/mip/mip_id.cgi), respectively, using BLAST. Enumeration of Legionella was determined by counting colonies that were identified as Legionella bacteria.

Amoeba co-culture

An Acanthamoeba sp. strain (CT1812-19) that was originally isolated from a cooling tower was grown in a 50-ml cell culture flask with 3 ml of peptone-yeast extract-glucose broth at 30 °C [Reference Rowbotham19]. The amoebae were harvested and pelleted by centrifugation at 1000  g for 10 min. The supernatant was removed, and the amoebae were resuspended in a 50-ml cell culture flask with 3 ml of 50-fold-diluted PBS. After the study samples were heat treated, 1·5 ml of each sample was added to a suspension of amoeba in a 50-ml cell culture flask and incubated at 25 °C for 3 days. After incubation, the culture was subjected to acid treatment and then inoculated onto selective agar plates as described above. Plates were incubated at 36 °C for at least 7 days, and suspected colonies were tested for Legionella.

Detection of Legionella DNA by LAMP and direct DNA analysis

To detect Legionella DNA in samples, a loop-mediated isothermal amplification (LAMP) assay (Eiken Chemical, Tokyo, Japan) was used [Reference Annaka20]. Re-suspensions of water samples, suspensions of swab samples, and amoebal co-culture solutions were subjected to DNA extraction using the alkali heat extraction method [Reference Beige21], in accordance with the manufacturer's instructions for LAMP assay. Negative (TE buffer) and positive controls (Legionella DNA) are provided with the kit. Every run of LAMP was performed with both control samples. The reactions in LAMP assays for Legionella were performed in a Loopamp Real-time Turbidimeter LA-320C (Eiken Chemical) at 65 °C for 60 min followed by 80 °C for 5 min to terminate the reaction. Turbidity was monitored spectrophotometrically at 650 nm with the LA-320C. The results were analyzed with the LA-320C software package. The detection limit of the assay was guaranteed 60 CFU per test-tube [Reference Annaka20], but we detected 1 CFU of L. pneumophila per tube in the LAMP reaction. All LAMP-positive DNA samples were tested using conventional PCR of the L. pneumophila-specific mip gene [Reference Nagai9]. For mip-positive DNAs, nested-SBT was performed (http://www.hpa-bioinformatics.org.uk/legionella/legionella_sbt/php/sbt_homepage.php).

Statistical analysis

Data were analyzed using SPSS for Windows release 17·0 (SPSS Inc., Chicago, IL, USA). Logarithmic transformation of HPCs was carried out to normalize the non-normal distributions. Univariate and stepwise multivariate logistic regressions to establish independent predictors of contamination were conducted. Logistic regression analyses were used to determine whether Legionella contamination was associated with a particular set of microbial and physical characteristics. Data were excluded from analysis if any single value was missing.

RESULTS

Detection of Legionella DNA

The detection rates of Legionella DNA were high among water samples from washing machines or aquariums and moderately high among water and swab samples from bathtub spouts (Tables 1 and 2). The duration of washing machine use ranged from 3 months to 14 years (mean, 5·88 years). Regardless of the duration of use, Legionella DNA was detected in samples from almost all washing machines.

Among water samples from water systems in homes, Legionella DNA was detected in 18 out of 61 samples (29·5%) collected from seven houses. Legionella DNA was detected in outlet water samples collected from two 30-year-old condominium units and five single-family houses that were each over 11 years old. A portion of the LAMP-positive samples was analyzed by SBT, sequencing both the 16S rRNA and mip genes. These analyses revealed that a swab sample from a bathtub spout contained L. pneumophila ST1966, and that an outlet water sample from a bathtub spout contained another mip-positive DNA with partial alleles (0, 0, 0, 0, 2, 0, 0) for SBT, although L. pneumophila SG1, ST22 was isolated from the same water sample.

Combining the amoeba co-culture method with a conventional culture method increased the LAMP detection rates from 31·9% (44 samples) to 47·8% (66 samples) in water samples and from 11·1% (10 samples) to 18·9% (17 samples) in swab samples (Tables 1 and 2).

Isolation of Legionella

The isolation rates of Legionella spp. in the samples were low. The combination of the amoeba co-culture method and conventional culture method increased the isolation rates of Legionella spp. from 5·8% (eight samples) to 6·5% (nine samples) in water samples and from 1·1% (one sample) to 3·3% (three samples) in swab samples (Tables 1 and 2). The number of Legionella in water samples detected by the culture method ranged from 15 to 370 CFU/100 ml (Table 1). L. pneumophila SG 1, ST22 was detected in outlet water samples from a bathtub spout and a bath sponge collected at the same house. Legionella DNA (16S rRNA gene) was also detected from a washing machine water sample collected in this house, but the L. pneumophila mip gene was not detected in this sample. Legionella DNA was not detected in other samples collected from this house, including outlet water samples from a shower, a hand-wash basin tap, and kitchen and bathroom taps.

Legionella sainthelensi and Legionella anisa were isolated from two aquarium water samples (20 and 25 CFU/100 ml) and one aquarium water sample (20 CFU/100 ml), respectively. Of the 30 total aquarium samples, two were collected from separate marine water aquariums. Legionella DNA was detected from both marine aquariums, and L. sainthelensi was isolated from one of the two marine water aquariums.

L. anisa was isolated from water samples from a bathtub (150 CFU/100 ml), an aquarium, and a pump hose from one house. In this house, the water leftover in the bathtub was used for changing the aquarium water and for washing in the washing machine. The leftover water was usually transferred from the bathtub to the washing machine using a water pump through a pump hose. Legionella DNA was detected in a washing machine water sample and a washing machine drum swab sample from this house, while L. anisa was not isolated from these samples.

Association between water characteristics and the detection of Legionella DNA

The associations of HPC, residual chlorine concentration, pH, and water temperature with the presence of Legionella DNA were evaluated by applying a univariate logistic regression analysis (Table 3). HPC and pH were positively associated with the presence of Legionella DNA, while the residual-free chlorine concentration showed an inverse association with the presence of Legionella DNA. Based on this initial finding, water sample HPC, pH, and residual chlorine concentration were introduced into a multivariate logistic regression model. HPC (odds ratio (OR) 1·443, 95% confidence interval (CI) 1·102–1·891, P < 0·01) and pH (OR 10·891, 95% CI 1·314–90·249, P < 0·05) were independently associated with the presence of Legionella DNA.

Table 3. Univariate logistic regression of parameters associated with Legionella contamination

s.d., standard deviation; OR, odds ratio; CI, confidence interval.

*P < 0·01; †P < 0·05.

The numbers of LAMP+ and LAMP samples from each sampling site used in the tests were as follows: kitchen tap: 3, 7; bathroom tap: 1, 9; bathtub spout: 6, 6; shower: 1, 4; hand-wash basin tap: 4, 6; bathtub water: 6, 2; toilet low tank: 1, 2; tank from a warm water washing toilet seat: 0, 1; washing machine: 10, 0; and garden hose in a house yard: 1, 3, respectively. Seven water samples that were collected from one house and were not included in Table 1, were used in Table 3.

DISCUSSION

Our study shows that Legionella is found in aquatic environments at multiple sites in homes. These aquatic environments may become potential sources of Legionella infection.

The risk of Legionella infection from the home water supply was initially reported by Stout et al. [Reference Stout, Yu and Muraca5] and later reviewed by Pedro-Botet et al. [Reference Pedro-Botet, Stout and Yu6]. They emphasized the importance of recognizing the home water supply as a source of Legionella transmission. However, those studies were based on a culture method and, therefore, could not detect bacteria that were in a viable-but-non-culturable state. In this study, we performed both culture and DNA detection. Legionella DNA was detected in many water system samples; specifically, Legionella DNA was identified in water samples from taps and showers collected in seven out of 14 houses. The Legionella DNA detection rates in outlet water samples from kitchen, bathroom, hand-wash basin, and house yard taps and from showers ranged from 0% to 52·9%, with an average of 29·5%, which was much higher than the bacterial isolation rates.

We determined the sequence type of L. pneumophila in LAMP-positive samples, when Legionella was not isolated. A swab DNA from a bathtub spout contained ST1966, which is very rare, but we registered ST1966 as a new ST from L. pneumophila SG4 clinical isolate in Kanagawa prefecture in 2014. There was no relationship between this survey and the patient, although the area and the period were synchronized.

Combining the results of culture and DNA detection provides an improved understanding of the occurrence of Legionella spp. in domestic environments, and although the LAMP method is not quantitative, it can detect dead cells as well as viable cells. In this study, the Legionella detection rates determined by the culture method were 6·5% in water samples and 3·3% in swab samples, which are quite low compared with the Legionella DNA detection rates. However, this is not surprising because the detection of Legionella DNA is reported to be more sensitive than that of Legionella by the conventional culture method. Wang et al. and Furuhata et al. similarly observed a low prevalence of Legionella by the culture method but a much higher prevalence by quantitative PCR in drinking-water distribution systems [Reference Wang22] and by LAMP in hot spring water [Reference Furuhata23], respectively.

The combination of DNA amplification and the amoeba co-culture method increased the sensitivity of Legionella DNA detection in environmental samples. The amoeba co-culture method has been previously reported as a means of isolating Legionella spp. from environmental and clinical samples. Conza et al. [Reference Conza, Casati and Gaia24] observed that a combination of the conventional culture method and the amoeba co-culture method yielded a three-log-higher sensitivity for detecting L. pneumophila from spiked compost. In this study, this combination also increased the positive rates of Legionella detection, especially at the DNA level.

The present study shows that Legionella is ubiquitous in homes and that there are multiple water environments in homes, where Legionella can colonize. While the risk of legionellae transmission from each of these aquatic environments is unclear, any aquatic environment contaminated with Legionella could be a potential source of Legionella dissemination. Redd and Cohen [Reference Redd and Cohen25] reported that despite the widespread presence of Legionella in the environment, sporadic legionellosis is relatively infrequent. This conclusion is partly the result of the low sensitivity of earlier diagnostic methods. The development of improved diagnostic methods, such as the urinary antigen test and DNA detection methods, now make it possible to detect previously undetected Legionella cases.

Legionellae were detected from a garden hose in our study. Because watering with a garden hose produces aerosols, which can transmit legionellosis, this poses a risk of transmitting Legionnaires’ disease. Cases of Legionnaires’ disease and Pontiac fever linked to garden hoses have been previously reported [Reference Piso, Caruso and Nebiker26].

Legionella DNA was also detected in showers and a toilet tank in this study. The presence of Legionella in showers has been previously described [Reference Bollin27]. Notably, toilet flushing and showers both generate aerosols, which may result in the inhalation of legionellae if the water in these sources is contaminated with Legionella [Reference Surman-Lee, Bartram, Chartier, Lee, Pond and Surman-Lee28]. Legionella DNA was also detected with a high frequency in washing machines and aquariums in the present study. Risk of exposure to microbial pathogens may occur through the inhalation of aerosols generated during the washing machine cycle and/or discharge of spent water from the washing machine [Reference O'Toole, Sinclair and Leder29]. Contamination of Legionella sp. in a washing machine may be related to the occurrence of legionellosis, through the generation and spreading of aerosols containing Legionella sp. in the household. Legionella DNA was found not only in samples from fresh water aquariums but also in those from marine water aquariums. Gast et al. [Reference Gast30] observed that amoeba were capable of harboring legionellae in marine water. Importantly, aeration devices for fish in aquariums and washing machines both generate aerosols. Legionellae can persist in aquariums and washing machines, and these devices may pose a potential risk of causing Legionella infection, especially among people in high-risk groups. Smith et al. [Reference Smith31] reported that L. pneumophila and L. birminghamensis DNA were detected in one each of 14 aquarium water samples. They stated that owners of ornamental fish and the pet industry should take responsibility for the health of the people who care for fish.

L. pneumophila SG1 is a major cause of legionellosis and accounts for approximately 80% of isolates from patients with community-acquired pneumonia both worldwide [Reference Yu32] and in Japan [Reference Amemura-Maekawa33]. In this study, a bath spout and a bath sponge from one house were each contaminated with L. pneumophila SG1, ST22, which is widely detected in patients as well as environments in many countries, but neither L. pneumophila nor Legionella DNA was detected from the water system of this house. These results suggest that L. pneumophila did not proliferate in the water system of this house and that bath spouts and bath sponges can persistently harbor and disseminate L. pneumophila. These environmental habitats could be reservoirs of L. pneumophila SG1.

The presence of Legionella spp. suggests the existence of biofilms and amoeba that might provide an appropriate environment for the proliferation of Legionella. In one of the houses from this study, L. anisa was detected in samples from bathtub water, an aquarium, and a pump hose. Based on a report by van der Mee-Marquet et al. [Reference van der Mee-Marquet34] that L. anisa could be an indicator of water contamination by L. pneumophila, our results additionally suggest that L. pneumophila may also be able to grow in these environments. Leftover water in the bathtub was reused in the washing machine to wash clothes or to change aquarium water in the house. In typical Japanese houses, washing machines are usually positioned outside a bathroom, and many Japanese washing machines are equipped with a water pump and a hose to transfer leftover bathtub water to the washing machine. Japanese typically soak in the bathtub but wash their bodies outside the bathtub, so the leftover water is thought to be clean enough to be reused. The results of this study suggest that L. anisa was disseminated from the bathtub into the washing machine through a pump hose and also into the aquarium.

In water systems, the detection rates of Legionella DNA were moderately high in samples from bathtub spouts (52·9%) and showers (25·0%). Additionally, bathtub water accounted for 37·5% of positive Legionella DNA samples. These results suggested that equipment in bathrooms provide an environment for Legionella colonization. Legionella DNA was also highly detected in kitchen taps and hand-wash basin taps. Samples from bath spouts, showers, bathtubs, kitchen taps, and hand-wash basin taps were characterized as having mean temperatures over 25 °C, although the results of logistic regression analysis in this study did not suggest that warm temperatures promoted Legionella growth.

L. sainthelensi was detected in two aquarium samples in this study. L. sainthelensi was originally isolated from a natural water environment [Reference Campbell35] and is rarely isolated from human cases. However, this species was reported as the causative agent of an outbreak of legionellosis in nursing homes with a contaminated water system [Reference Loeb36]. Legionella busanensis and Legionella rowbothamii, which were detected in samples from a home garden hose and from the outlet water of a kitchen tap, respectively, in this study, are also rarely isolated species. L. busanensis was previously isolated from cooling towers [Reference Diederen37]. To our knowledge, there have been no reports of L. busanensis or L. rowbothamii being isolated from legionellosis patients.

Controlling biofilm formation for Legionella prevention is difficult, especially in pipes. The results of our logistic regression analysis show that HPC is associated with the presence of Legionella, suggesting that a reduction of HPC may be effective for Legionella control. Our results also suggest that pH is positively associated with the presence of Legionella. Leoni et al. [Reference Leoni38] and Marrie et al. [Reference Marrie39] reported similar results. Results of logistic regression analysis did not indicate the association of Legionella colonization and temperature possibly because the temperature of the water samples collected in this study ranged from 16·0 to 39·5 °C, and these temperatures were too low to eradicate Legionella. Although multivariate logistic regression analysis using data collected in the present study did not show that residual chlorine concentrations independently affected Legionella contamination, effective concentrations of residual chlorine can generally disinfect HPC and Legionella in aquatic environments.

Measures for preventing Legionella contamination in houses should include frequent flushing of taps and showers to expel water harboring heterotrophic bacteria, such as stagnant water, and increasing daily water consumption [Reference Pedro-Botet, Stout and Yu6]. Additional measures include frequently cleaning and disinfecting hoses, washing machines, bathtubs, and sponges with a disinfectant, such as chlorine, to prevent biofilm formation. Furthermore, where possible preventing aerosols from aquatic environments that could potentially be contaminated with Legionella, such as toilets [Reference Surman-Lee, Bartram, Chartier, Lee, Pond and Surman-Lee28], washing machines, and aquariums, may also be effective.

There were some limitations in this study. First, those were the small number, location and selection of houses investigated. Therefore, the results should not be considered representative of typical Japanese households. Second, the LAMP assay detects Legionella that is dead or alive with high sensitivity, resulting in the possibility of overestimation of Legionella risk. Despite these limitations, we believe our study provides important information regarding domestic Legionella infection.

In conclusion, our results reveal that aquatic environments in Japanese houses are highly contaminated with Legionella, and they suggest that exposure to Legionella spp. in these aquatic environments could increase the risk of legionellosis. Water systems can be a source of transmission of Legionella spp. Washing machines and aquariums should also be considered as potential sources of legionellosis. This study additionally reveals that Legionella contamination is associated with HPC and pH. Among these characteristics, reduction of HPC may be particularly important for preventing Legionella contamination. To minimize such contamination, control measures should include frequently flushing taps and showers to expel water harboring heterotrophic bacteria, frequently cleaning and disinfecting surfaces to remove biofilms, and preventing aerosols from aquatic environments as much as possible. The effects of the preventive measures recommended herein should be investigated in future studies.

ACKNOWLEDGEMENTS

This study was partially supported by Health and Labour Sciences Research Grants (H25-kenki-ippan-007, H25-kenki-ippan-009, H28-kenki-ippan-005, and H28-kenki-ippan-006) from the Ministry of Health, Labour and Welfare of Japan. We thank Dr K. Yagita, Department of Parasitology, National Institute of Infectious Diseases, for kindly providing an Acanthamoeba strain.

DECLARATION OF INTEREST

None.

Footnotes

The author has retired.

References

REFERENCES

1. Mercante, JW, Winchell, JM. Current and emerging Legionella diagnostics for laboratory and outbreak investigations. Clinical Microbiology Reviews 2015; 28: 95133.CrossRefGoogle ScholarPubMed
2. Fields, BS, Benson, RF, Besser, RE. Legionella and Legionnaires’ disease: 25 years of investigation. Clinical Microbiology Reviews 2002; 15: 506526.Google Scholar
3. Atlas, RM. Legionella: from environmental habitats to disease pathology, detection and control. Environmental Microbiology 1999; 1: 283293.CrossRefGoogle ScholarPubMed
4. Straus, WL, et al. Risk factors for domestic acquisition of legionnaires disease. Archives of Internal Medicine 1996; 156: 16851692.Google Scholar
5. Stout, JE, Yu, VL, Muraca, P. Legionnaires’ disease acquired within the homes of two patients: link to the home water supply. Journal of American Medical Association 1987; 257: 12151217.CrossRefGoogle Scholar
6. Pedro-Botet, ML, Stout, JE, Yu, VL. Legionnaires’ disease contracted from patient homes: the coming of the third plague? European Journal of Clinical Microbiology and Infectious Diseases 2002; 21: 699705.Google ScholarPubMed
7. National Institute of Infectious Diseases and Tuberculosis and Infectious Diseases Control Division, Ministry of Health, Labour and Welfare. Legionellosis, January 2008–December 2012. Infectious Agents Surveillance Report 2013; 34: 155156.Google Scholar
8. National Institute of Infectious Diseases and Tuberculosis and Infectious Diseases Control Division, Ministry of Health, Labour and Welfare. Legionellosis, April 1999–July 2000. Infectious Agents Surveillance Report 2000; 21: 186187.Google Scholar
9. Nagai, T, et al. Neonatal sudden death due to Legionella pneumonia associated with water birth in a domestic spa bath. Journal of Clinical Microbiology 2003; 41: 22272229.Google Scholar
10. Makin, T, Hart, CA. The efficacy of control measures for eradicating legionellae in showers. Journal of Hospital Infection 1990; 16: 17.Google Scholar
11. Wadowsky, RM, et al. Effect of temperature, pH, and oxygen level on the multiplication of naturally occurring Legionella pneumophila in potable water. Applied and Environmental Microbiology 1985; 49: 11971205.CrossRefGoogle ScholarPubMed
12. Mathys, W, et al. Occurrence of Legionella in hot water systems of single-family residences in suburbs of two German cities with special reference to solar and district heating. International Journal of Hygiene and Environmental Health 2008; 211: 179185.Google Scholar
13. Kasuga, O, et al. Studies on detection methods for Legionella species from environmental water. Kansenshogaku Zasshi 1999; 73: 2534. (in Japanese).Google Scholar
14. Bopp, CA, et al. Isolation of Legionella spp. from environmental water samples by low-pH treatment and use of a selective medium. Journal of Clinical Microbiology 1981; 13: 714719.Google Scholar
15. Gaia, V, et al. Consensus sequence-based scheme for epidemiological typing of clinical and environmental isolates of Legionella pneumophila . Journal of Clinical Microbiology 2005; 43: 20472052.Google Scholar
16. Ratzow, S, et al. Addition of neuA, the gene encoding N-acylneuraminate cytidylyl transferase, increases the discriminatory ability of the consensus sequence-based scheme for typing Legionella pneumophila serogroup 1 strains. Journal of Clinical Microbiology 2007; 45: 19651968.CrossRefGoogle ScholarPubMed
17. Ratcliff, RM, et al. Sequence-based classification scheme for the genus Legionella targeting the mip gene. Journal of Clinical Microbiology 1998; 36: 15601567.Google Scholar
18. Ratcliff, RM. Sequence-based identification of Legionella . In: Buchrieser, C, Hilbi, H, eds. Legionella Methods and Protocols: Methods in Molecular Biology. Totowa: Humana Press, 2013, pp. 5772.CrossRefGoogle Scholar
19. Rowbotham, TJ. Isolation of Legionella pneumophila from clinical specimens via amoebae, and the interaction of those and other isolates with amoebae. Journal of Clinical Pathology 1983; 36: 978986.Google Scholar
20. Annaka, T. et al. Rapid and simple detection of Legionella species by LAMP, a new DNA amplification method. Journal of Japanese Society for Clinical Microbiology 2003; 13: 1921. (in Japanese).Google Scholar
21. Beige, J, et al. Clinical evaluation of a Mycobacterium tuberculosis PCR assay. Journal of Clinical Microbiology 1995; 33: 9095.CrossRefGoogle ScholarPubMed
22. Wang, H, et al. Molecular survey of the occurrence of Legionella spp., Mycobacterium spp., Pseudomonas aeruginosa, and amoeba hosts in two chloraminated drinking water distribution systems. Applied and Environmental Microbiology 2012; 78: 62856294.CrossRefGoogle ScholarPubMed
23. Furuhata, K, et al. Comparison of loop-mediated isothermal amplification (LAMP) and conventional culture for the detection of Legionella species in hot spring water samples in Japan. Biocontrol Science 2005; 10: 117120.Google Scholar
24. Conza, L, Casati, S, Gaia, V. Detection limits of Legionella pneumophila in environmental samples after co-culture with Acanthamoeba polyphaga . BMC Microbiology 2013; 26: 1349.Google Scholar
25. Redd, SC, Cohen, ML. Legionella in water: what should be done? Journal of American Medical Association 1987; 257: 12211222.CrossRefGoogle Scholar
26. Piso, RJ, Caruso, A, Nebiker, M. Hose as a source of Legionella pneumonia. A new risk factor for gardeners? Journal of Hospital Infection 2007; 67: 396397.Google Scholar
27. Bollin, GE, et al. Aerosols containing Legionella pneumophila generated by shower heads and hot-water faucets. Applied and Environmental Microbiology 1985; 50: 11281131.Google Scholar
28. Surman-Lee, S, et al. Ecology and environmental sources of Legionella . In: Bartram, J, Chartier, Y, Lee, JV, Pond, K, Surman-Lee, S, eds. Legionella and the prevention of legionellosis. Geneva: World Health Organization, 2007, pp. 2938.Google Scholar
29. O'Toole, J, Sinclair, M, Leder, K. Transfer rates of enteric microorganisms in recycled water during machine clothes washing. Applied and Environmental Microbiology 2009; 75: 12561263.Google Scholar
30. Gast, RJ, et al. Amoebae and Legionella pneumophila in saline environments. Journal of Water and Health 2011; 9: 3752.Google Scholar
31. Smith, KF, et al. Microbial diversity and potential pathogens in ornamental fish aquarium water. PLoS ONE 2012; 7: e39971. doi.org/10.1371/journal.pone. 0039971.CrossRefGoogle ScholarPubMed
32. Yu, VL, et al. Distribution of Legionella species and serogroups isolated by culture in patients with sporadic community-acquired legionellosis: an international collaborative survey. Journal of Infectious Diseases 2002; 186: 127128.Google Scholar
33. Amemura-Maekawa, J, et al. Characterization of Legionella pneumophila isolates from patients in Japan according to serogroups, monoclonal antibody subgroups and sequence types. Journal of Medical Microbiology 2010; 59: 653659.Google Scholar
34. van der Mee-Marquet, N, et al. Legionella anisa, a possible indicator of water contamination by Legionella pneumophila . Journal of Clinical Microbiology 2006; 44: 5659.Google Scholar
35. Campbell, J, et al. Legionella sainthelensi: a new species of Legionella isolated from water near Mt. St. Helens. Applied and Environmental Microbiology 1984; 47: 369373.CrossRefGoogle ScholarPubMed
36. Loeb, M, et al. Surveillance for outbreaks of respiratory tract infections in nursing homes. Canadian Medical Association Journal 2000; 162: 11331137.Google ScholarPubMed
37. Diederen, BM, et al. Molecular evidence for the ubiquitous presence of Legionella species in Dutch tap water installations. Journal of Water and Health 2007; 5: 375383.Google Scholar
38. Leoni, E, et al. Legionella waterline colonization: detection of Legionella species in domestic, hotel and hospital hot water systems. Journal of Applied Microbiology 2005; 98: 373379.CrossRefGoogle ScholarPubMed
39. Marrie, T, et al. Legionellaceae in the potable water of Nova Scotia hospitals and Halifax residences. Epidemiology and Infection 1994; 112: 143150.CrossRefGoogle ScholarPubMed
Figure 0

Table 1. Household Legionella contamination in water samples

Figure 1

Table 2. Household Legionella contamination in swab samples

Figure 2

Table 3. Univariate logistic regression of parameters associated with Legionella contamination