Hostname: page-component-78c5997874-s2hrs Total loading time: 0 Render date: 2024-11-14T22:07:44.243Z Has data issue: false hasContentIssue false

Single tube confirmatory tests for Escherichia coli

Published online by Cambridge University Press:  15 May 2009

Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

In a multi-laboratory trial, lauryl tryptose mannitol broth (LTMB) and minerals-modified glutamate medium with added tryptophan (MMGM + T) were compared as single tube tests for the confirmation of Escherichia coli in water; the confirmed results were also compared with the production of gas from minerals-modified glutamate medium without added tryptophan (MMGM). LTMB and MMGM + T gave similar gas and indole results with about 90% of the water samples in most of the laboratories. When compared with the ‘correct’ results as judged by acid and gas production from lactose peptone water and indole from tryptone water, the difference in the rate of false positive reactions between LTMB and MMGM + T was insignificant; but LTMB gave a significantly lower rate of false negative reactions than MMGM + T. Gas production from MMGM without added tryptophan gave significantly higher rates of both false positive and false negative reactions. Lauryl sulphate is therefore a suitable inhibitory surfactant for use in single tubemedia for the confirmation of E. coli, which can be recommended.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1980

References

Boyd, W. L. & Lichstein, H. C. (1955). The effect of carbohydrates on the tryptophanase activity of bacteria. Journal of Bacteriology 69, 584.CrossRefGoogle ScholarPubMed
Fennel, H. (1972). A single tube confirmatory test for E. coli at 44 °C. Water Treatment and Examination 21, 13.Google Scholar
Gray, R. D. (1964). An improved formate lactose glutamate medium for the detection of Escherichia coli and other coliform organisms in water. Journal of Hygiene 62, 495.Google ScholarPubMed
Mara, D. D. (1973). A single medium for the rapid detection of Escherichia coli at 44 °C. Journal of Hygiene 71, 783.Google Scholar
PHLS Standing Committee on the Bacteriological Examination of Water Supplies (1968). Confirmatory tests for coliform organisms. Journal of Hygiene 66, 641.Google Scholar
PHLS Standing Committee on the Bacteriological Examination of Water Supplies (1969). A minerals-modified glutamate medium for the enumeration of coliform organisms in water. Journal of Hygiene 67, 367.CrossRefGoogle Scholar
Public Health Laboratory Service and Standing Committee of Analysts (1980). A comparison between minerals-modified glutamate medium and lauryl tryptose lactose broth for the enumeration of Escherichia coli and coliform organisms in water by the multiple tube test. Journal of Hygiene. 85, 35.CrossRefGoogle Scholar
Pugsley, A. P., Evison, L. M. & James, A. (1973). A simple technique for the differentiation of Escherichia coli in water. Water Research 7, 1431.CrossRefGoogle Scholar
Report (1969). The Bacteriological Examination of Water Supplies. Reports on Public Health and Medical Subjects, no. 71. London: H.M.S.O.Google Scholar
Schubert, R. (1956). Die coliform Bakterien in der Wasserdiagnostik und ihre Differenzierungen. Zeitschrift für Hygiene und Infektionskrankheiten 142, 476–86.CrossRefGoogle Scholar
Schubert, R. (1958). Studien zur Differenzierung coliformen Bakterien in der Wasserdiagnostik. Zeitschrift für Hygiene und Infektionskrankheiten 144, 485–95.CrossRefGoogle Scholar