Hostname: page-component-78c5997874-4rdpn Total loading time: 0 Render date: 2024-11-14T04:26:35.466Z Has data issue: false hasContentIssue false

The use of spore strips for monitoring the sterilization of bottled fluids

Published online by Cambridge University Press:  15 May 2009

J. B. Selkon
Affiliation:
Regional Public Health Laboratory, General Hospital, Newcastle-upon-Tyne NE4 6BE
Penelope R. Sisson
Affiliation:
Regional Public Health Laboratory, General Hospital, Newcastle-upon-Tyne NE4 6BE
H. R. Ingham
Affiliation:
Regional Public Health Laboratory, General Hospital, Newcastle-upon-Tyne NE4 6BE
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

A bacterial spore test has been developed which enables the efficacy of the sterilizing cycle recommended by the British Pharmaceutical Codex (1973) for bottled fluids to be accurately monitored. During a 14-month period this test detected faults in 3.3% of the sterilizing cycles, representing five distinct episodes of sterilization failure that passed unnoticed by the conventional controls of physical measurements and sterility testing. There were no failures of sterilization as detected by conventional techniques which were not indicated by the spore test.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1979

References

British Pharmaceutical Codex (1973). Prepared in the Department of Pharmaceutical Sciences of the Pharmaceutical Society of Great Britain and published by direction of Society's Council. London: Pharmaceutical Press.Google Scholar
European Pharmacopoeia (1971). 11, 53.Google Scholar
Guide to Good Pharmaceutical Manufacturing Practice(1977), p. 47. London: H.M.S.O.Google Scholar
Kelsey, J. C. (1961). The testing of sterilizers. 2. Thermophilic spore papers. Journal of Experimental Biology 14, 313.Google ScholarPubMed
Phillips, I., Eykyn, S. & Laker, M. (1972). Outbreak of hospital infection caused by contaminated autoclaved fluids. Lancet i, 1258.CrossRefGoogle Scholar
Rubbo, S. D. & Gardner, J. F. (1965). A Review of Sterilization and Disinfection. London: Lloyd-Luke.Google Scholar
Williams, D. J., Franklin, J. G., Chapman, H. R. & Clegg, L. F. L. (1957). Methods of assessing the sporicidal efficiency of an ultra-high-temperature milk sterilizing plant. 1. Experiments with suspensions of spores in water. Journal of applied Bacteriology 20, 43.CrossRefGoogle Scholar