Hostname: page-component-78c5997874-fbnjt Total loading time: 0 Render date: 2024-11-13T08:17:00.390Z Has data issue: false hasContentIssue false

Biplane transoesophageal echocardiographic detection of myocardial ischaemia in patients with coronary artery disease undergoing non-cardiac surgery: segmental wall motion vs. electrocardiography and haemodynamic performance

Published online by Cambridge University Press:  16 August 2006

N. Kolev
Affiliation:
Department of Anesthesiology and General Intensive Care, University Hospital of Vienna, Vienna, Austria
G. Ihra
Affiliation:
Department of Anesthesiology and General Intensive Care, University Hospital of Vienna, Vienna, Austria
J. Swanevelder
Affiliation:
Department of Anaethesia and Clinical Care, The Glenfield Hospital, Leicester, UK
C. K. Spiss
Affiliation:
Department of Anesthesiology and General Intensive Care, University Hospital of Vienna, Vienna, Austria
T. Hartmann
Affiliation:
Department of Anesthesiology and General Intensive Care, University Hospital of Vienna, Vienna, Austria
M. Zimpfer
Affiliation:
Department of Anesthesiology and General Intensive Care, University Hospital of Vienna, Vienna, Austria
Get access

Abstract

Intra-operative segmental wall motion abnormalities (SWMA) detected by transoesophageal echocardio- graphy (TOE) have been shown to be a sensitive indicator of myocardial ischaemia. To determine the incidence and characteristics of segmental wall motion abnormalities and to relate these changes to peri-operative myocardial ischaemia, biplane TEE, electrocardiogram (ECG) (II + V5) and pulmonary capillary wedge pressure (PCWP) were continuously monitored in 62 consecutive patients with ischaemic heart disease undergoing non-cardiac surgery. Short-axis view at mid-papillary level in transverse scan (T-scan) and long-axis in longitudinal (L-scan) two-chamber view were used for wall motion analysis. New segmental wall motion abnormalities were detected in 16 of 64 patients (25%) using biplane transoesophageal echocardiography. Monoplane transoesophageal echocardiography showed a sensitivity of 75% and a specificity of 100%, electrocardiogram two lead showed a sensitivity of 56% and a specificity of 98%, whereas pulmonary capillary wedge pressure had a sensitivity of 25%, and a specificity of 93% and pressure rate quotient (PRQ) < 1 demonstrated sensitivity of 19% and a specificity of 92% in the detection of myocardial ischaemia. It is concluded that the long-axis view of the left ventricle provides additional information for the detection of segmental wall motion abnormalities. Neither changes in haemodynamic performance nor in electrocardiography leads II and V5 match those of transoesophageal echocardiography for the identification of myocardial ischaemia.

Type
Original Article
Copyright
1997 European Society of Anaesthesiology

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)