Hostname: page-component-cd9895bd7-8ctnn Total loading time: 0 Render date: 2024-12-27T08:42:40.541Z Has data issue: false hasContentIssue false

Changes in jugular bulb oxygenation in patients undergoing warm coronary artery bypass surgery (34–37°C)

Published online by Cambridge University Press:  16 August 2006

M. Shaaban-Ali
Affiliation:
Department of Anaesthetics and Intensive Care Medicine, University of Wales College of Medicine, Heath Hospital, Heath Park, Cardiff, CF14 4XN, UK
M. Harmer
Affiliation:
Department of Anaesthetics and Intensive Care Medicine, University of Wales College of Medicine, Heath Hospital, Heath Park, Cardiff, CF14 4XN, UK
R. S. Vaughan
Affiliation:
Department of Anaesthetics and Intensive Care Medicine, University of Wales College of Medicine, Heath Hospital, Heath Park, Cardiff, CF14 4XN, UK
J. A. Dunne
Affiliation:
Department of Anaesthetics and Intensive Care Medicine, University of Wales College of Medicine, Heath Hospital, Heath Park, Cardiff, CF14 4XN, UK
I. P. Latto
Affiliation:
Department of Anaesthetics and Intensive Care Medicine, University of Wales College of Medicine, Heath Hospital, Heath Park, Cardiff, CF14 4XN, UK
Get access

Abstract

Background and objective Imbalance between cerebral oxygen supply and demand is thought to play an important role in the development of cerebral injury during cardiac surgery with cardiopulmonary bypass.

Methods We studied jugular bulb oxygen saturation, jugular bulb oxygen tension, arterial–jugular bulb oxygen content difference and oxygen extraction ratio in 20 patients undergoing warm coronary artery bypass surgery (34–37°C) with pH-stat blood gas management.

Results Only two patients showed desaturation (jugular bulb oxygen saturation <50%) at 5 min on bypass, and none from 20 min onwards. Multiple regression models were performed after using bypass temperature, mean arterial pressure, cerebral perfusion pressure, haemoglobin concentration and arterial carbon dioxide tension as independent variables, and arterial–jugular bulb oxygen content difference, jugular bulb oxygen saturation, oxygen extraction ratio and jugular bulb oxygen tension as individual dependent variables.

Conclusions We found that jugular bulb oxygen saturation, jugular bulb oxygen tension and oxygen extraction ratio are mainly dependent on arterial carbon dioxide tension, and arterial–jugular bulb oxygen content difference is dependent on arterial carbon dioxide tension and the bypass temperature. Our results suggest jugular bulb oxygenation is mainly dependent on arterial carbon dioxide tension during warm cardiopulmonary bypass.

Type
Original Article
Copyright
2001 European Society of Anaesthesiology

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)