Hostname: page-component-78c5997874-xbtfd Total loading time: 0 Render date: 2024-11-10T14:39:32.360Z Has data issue: false hasContentIssue false

Optimal depth of insertion of left-sided double-lumen endobronchial tubes cannot be predicted from body height in below average-sized adult patients

Published online by Cambridge University Press:  23 December 2005

M. Yasumoto
Affiliation:
Fukuoka University School of Medicine, Department of Anesthesiology, Fukuoka, Japan
K. Higa
Affiliation:
Fukuoka University School of Medicine, Department of Anesthesiology, Fukuoka, Japan
K. Nitahara
Affiliation:
Fukuoka University School of Medicine, Department of Anesthesiology, Fukuoka, Japan
S. Shono
Affiliation:
Fukuoka University School of Medicine, Department of Anesthesiology, Fukuoka, Japan
T. Hamada
Affiliation:
Fukuoka University School of Medicine, Department of Anesthesiology, Fukuoka, Japan
Get access

Extract

Summary

Background and objective: The optimal depth of insertion of left-sided double-lumen endobronchial tubes is strongly correlated with body height in average-sized adults. However, this relationship has not been studied in below average-sized adult patients. We investigated whether or not there is a clinically useful relationship in below average-sized adult patients. Methods: One hundred and ninety six consecutive adult patients undergoing thoracic surgery under one-lung anaesthesia (body height 155 cm) were included in this study. Left-sided double-lumen tubes were inserted under the guidance of a fibre-optic bronchoscope. Optimal depth was defined as the proximal surface of the bronchial cuff positioned just below the carina. Results: There was a statistically significant positive correlation between body height and the optimal depth of insertion (r = 0.61, P < 0.0001); however, the correlation coefficient was low. The actual optimal depth of insertion of one patient was even 4.5 cm shorter than that obtained from the equation. Conclusion: Although there was a statistically significant correlation between body height and the optimal depth of insertion of left sided double lumen tubes in adult patients of short stature ( 155 cm), clinical application of the equation is not warranted and these tubes should be inserted under direct vision with a fibre-optic bronchoscope.

Type
Original Article
Copyright
© 2006 European Society of Anaesthesiology

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Benumof JL, Partridge BL, Salvatierra C, Keating J. Margin of safety in positioning modern double-lumen endotracheal tubes. Anesthesiology 1987; 67: 729738.Google Scholar
Brodsky JB, Benumof JL, Ehrenwerth J, Ozaki GT. Depth of placement of left-sided double-lumen endobronchial tubes. Anesth Analg 1991; 73: 570572.Google Scholar
Bahk JH, Oh YS. Prediction of double-lumen tracheal tube depth. J Cardiothorac Vasc Anesth 1999; 13: 370371.Google Scholar
Dyer RA, Heijke SAM, Russell WJ, Bloch MB, James MF. Can insertion length for a double-lumen endobronchial tube be predicted? Anaesth Intens Care 2000; 28: 666668.Google Scholar
Chow MY, Goh MH, Ti LK. Predicting the depth of insertion of left-sided double-lumen endobronchial tubes. J Cardiothorac Vasc Anesth 2002; 16: 456458.Google Scholar
Sakuragi T, Kumano K, Yasumoto M, Dan K. Rupture of the left main-stem bronchus by the tracheal portion of a double-lumen endobronchial tube. Acta Anaesthesiol Scand 1997; 41: 12181220.Google Scholar
Chow MYH, Liam BL, Lew TWK, Chelliah RY, Ong BC. Predicting the size of a double-lumen endobronchial tube based on tracheal diameter. Anesth Analg 1998; 87: 158160.Google Scholar
Shinnick JP, Freedman AP. Bronchofiberscopic placement of a double-lumen endotracheal tube. Crit Care Med 1982; 10: 544545.Google Scholar
Gilbert TB, Goodsell CW, Krasna MJ. Bronchial rupture by a double-lumen endobronchial tube during staging thoracoscopy. Anesth Analg 1999; 88: 12521253.Google Scholar
Cheong KF, Koh KF. Placement of left-sided double-lumen endobronchial tubes: comparison of clinical and fiberoptic-guided placement. Br J Anaesth 1999; 82: 920921.Google Scholar