1 Introduction
Large laser facilities, such as the National Ignition Facility at Lawrence Livermore National Laboratory, are often at the forefront of laser-driven laboratory astrophysics[Reference Remington, Drake and Ryutov1, Reference Gregori, Reville and Miniati2], in which experiments seek to model astrophysical systems by scaling key dimensionless variables to the laboratory[Reference Remington, Arnett, Paul Drake and Takabe3, Reference Ryutov, Remington, Robey and Drake4]. An important subset of these experiments is concerned with the interaction of one or more energetic plasmas with an ambient plasma, such as in studies of collisionless shocks[Reference Schaeffer, Fox, Haberberger, Fiksel, Bhattacharjee, Barnak, Hu and Germaschewski5], magnetic reconnection[Reference Fiksel, Fox, Bhattacharjee, Barnak, Chang, Germaschewski, Hu and Nilson6], mini-magnetospheres[Reference Shaikhislamov, Zakharov, Posukh, Melekhov, Antonov, Boyarintsev and Ponomarenko7], or self-generated magnetic fields[Reference Gregori, Ravasio, Murphy, Schaar, Baird, Bell, Benuzzi-Mounaix, Bingham, Constantin, Drake, Edwards, Everson, Gregory, Kuramitsu, Lau, Mithen, Niemann, Park, Remington, Reville, Robinson, Ryutov, Sakawa, Yang, Woolsey, Koenig and Miniati8]. However, in regard to such experiments, these facilities suffer from two main drawbacks: an inherently limited shot rate (of order ten or less for a given experimental campaign), and the necessity to dynamically create ambient plasmas with lasers. The low number of shots yields small datasets and reduces the number of parameters that can be explored, while laser-driven ambient plasmas are difficult to control and diagnose.
The Large Plasma Device (LAPD) at the University of California, Los Angeles (UCLA) addresses some of these shortcomings by providing a high-repetition-rate, highly repeatable, long-lived and well-diagnosed ambient plasma. Previous experiments on the LAPD have utilized commercially available, high-repetition-rate lasers to study the magnetic[Reference VanZeeland, Gekelman, Vincena and Dimonte9–Reference Collette and Gekelman12] and electric fields[Reference Bonde, Vincena and Gekelman13] involved in the formation of diamagnetic cavities. These experiments demonstrated how large, detailed volumetric datasets could be acquired in laser plasmas, but the lasers employed were too low intensity ( ${\sim}10^{10}~\text{W}/\text{cm}^{2}$ ) and too low energy ( ${\lesssim}1.5~\text{J}$ ) to drive the highly energetic plasmas necessary for laboratory astrophysics.
In this paper, we overview a new experimental platform at UCLA that combines the LAPD with a high-power, high-repetition-rate laser that is capable of on-target intensities in excess of $10^{14}~\text{W}/\text{cm}^{2}$ . This platform allows new 3D volumetric data collection of the interaction between laser-driven plasma plumes and a magnetized ambient plasma. We present the first experimental results using this platform, and discuss its potential application to topics in laboratory astrophysics, including the study of both perpendicular and parallel low-Mach number magnetized shocks, the formation of magnetic instabilities and kinetic-scale magnetospheres.
2 Experimental platform and setup
The experiments were carried out at UCLA utilizing a high-repetition-rate laser in the Phoenix Laser Laboratory[Reference Niemann, Constantin, Schaeffer, Tauschwitz, Weiland, Lucky, Gekelman, Everson and Winske14] and the LAPD[Reference Gekelman, Pribyl, Lucky, Drandell, Leneman, Maggs, Vincena, Van Compernolle, Tripathi, Morales, Carter, Wang and DeHaas15] operated by the Basic Plasma Science Facility (BaPSF). A schematic of the experimental setup is shown in Figure 1. The LAPD is a 20 m long, 1 m diameter cylindrical vacuum vessel that can generate a steady-state ( ${\sim}15~\text{ms}$ ), current-free magnetized ambient plasma at repetition rates up to 1 Hz. Multiple current-carrying coils along the machine provide uniform axial magnetic fields up to 2 kG. A BaO-coated Ni cathode at one end of the machine provides the main 60-cm-diameter ambient plasma, which can be composed of various gases (H, D, He). A second $\text{LaB}_{6}$ cathode at the other end of the machine provides a higher-density 20-cm-diameter core plasma centered on the main plasma. Consequently, the ambient plasma electron density varies from $n_{e}\approx 5\times 10^{12}~\text{cm}^{-3}$ at the edge to $n_{e}\approx 2\times 10^{13}~\text{cm}^{-3}$ at the center, with an electron temperature of ${\sim}5{-}10~\text{eV}$ and ion temperature of ${\sim}1~\text{eV}$ .
The high-repetition-rate laser was originally designed[Reference Dane, Zapata, Neuman, Norton and Hackel16, Reference Dane and Hackel17] at Lawrence Livermore National Laboratory and was recently re-commissioned at UCLA. It can deliver energies of 20 J at 1053 nm and variable pulse widths of 8–30 ns (full width at half-maximum, FWHM) in a near-diffraction-limited beam, yielding powers up to 2.5 GW, potential intensities in excess of $10^{14}~\text{W}/\text{cm}^{2}$ , and repetition rates up to 4 Hz. The output laser energy is stable to within 5%, and the pulse shape, diffraction-limited focus, and beam pointing are stable to within 1%. Additional details on the performance of the laser can be found in Ref. [Reference Dane and Hackel17].
In the experiments, a high-density polyethylene ( $\text{C}_{2}\text{H}_{4}$ ) plastic target, 30.5 cm long and 38 mm in diameter, was positioned 30 cm from the LAPD center axis. The target was mounted on a 2D stepper motor drive synchronized with the laser, which translated and rotated the target in a helical pattern. Each target position was repeated three times and then moved to provide a fresh surface. A single target could thus be used for up to $2\times 10^{4}$ laser shots. The laser was configured with a 14 ns pulse width (FWHM) and directed through an $f/10$ lens at an angle of $30^{\circ }$ relative to the target normal, which ablated the target with intensities up to $I\approx 6\times 10^{13}~\text{W}\cdot \text{cm}^{-2}$ . Due to the low ambient density, the laser had a negligible effect on the ambient plasma over the regions of interest. The target and laser were oriented so that the laser-ablated plasma was directed across the background field. The laser and target were synchronized to the LAPD, and they all operated at a repetition rate of 0.23 Hz to allow time for the diagnostics to position themselves between shots.
The position of the laser spot on the target defines as $\{x,y,z\}=\{0,0,0\}~\text{cm}$ , with the background magnetic field directed along $\hat{z}$ , the target surface normal directed along $\hat{x}$ , and the vertical motion of the target directed along ${\hat{y}}$ . The center of the LAPD is then at $\{x,y\}=\{30,0\}~\text{cm}$ . Diagnostics was positioned in the planes defined by $z=0$ ( $x$ – $y$ plane) or $y=0$ ( $x$ – $z$ plane). The firing of the laser defines as $t=0=t_{0}$ .
The magnetic field was characterized using 1 mm diameter, three-axis magnetic flux (‘bdot’) probes[Reference Everson, Pribyl, Constantin, Zylstra, Schaeffer, Kugland and Niemann18]. The probes were positioned using a 2D stepper motor drive configured to move in either the $x$ – $z$ or $x$ – $y$ plane. Each position was repeated three times to generate statistics, and a 2D plane of data was assembled by moving the probe in 5 mm increments in a grid pattern over successive laser shots. The bdot signals were passed through a 150 MHz differential amplifier and coupled to fast (1.25 GHz) 10-bit digitizers, and then integrated to yield magnetic field.
The electrostatic plasma potential was measured using a resistively heated $\text{CeB}_{6}$ emissive probe[Reference Martin, Bonde, Gekelman and Pribyl19]. For each shot the emissive probe began sampling before the laser fired, which served to measure the ambient plasma potential. This potential was then used as a reference for measurements of the potential taken after the laser fired. Like the bdot probes, the emissive probes were positioned using a 2D stepper motor drive, and each position was repeated three times and incremented in 5 mm steps to assemble 2D planes of data.
Images of the interaction of the laser plasma and ambient plasma were acquired with a fast-gate (10 ns) intensified charge-coupled device (ICCD) camera. The camera was positioned either above the target or at the end of the machine to image the $x$ – $z$ and $x$ – $y$ planes, respectively. Data was acquired in 10 ns increments simultaneously with the measurements of the magnetic field or plasma potential. The camera collected light from broadband plasma self-emission and could be additionally filtered to isolate specific ion charge states. Results from the fast-gate imaging can be found in Ref. [Reference Heuer, Schaeffer, Knall, Constantin, Hofer, Vincena, Tripathi and Niemann20].
Additionally, swept Langmuir probes were employed to measure similar $x$ – $z$ and $x$ – $y$ planes of plasma electron density and temperature. These measurements were carried out in the absence of the laser plasma, and so provided the initial state of the ambient plasma at $t_{0}$ .
3 Results
Magnetic field and electrostatic potential measurements were acquired in both the $x$ – $z$ and $x$ – $y$ planes. In the $x$ – $z$ plane, the magnetic probe scanned from $x=5.5~\text{cm}$ to $x=29.5~\text{cm}$ and $z=-12~\text{cm}$ to $z=12~\text{cm}$ over a total of 1875 shots (where each position was repeated three times), while the emissive probe scanned from $x=15~\text{cm}$ to $x=29~\text{cm}$ and $z=-8~\text{cm}$ to $z=12$ using 945 shots. In the $x$ – $y$ plane, in order to avoid hitting the probes with the laser, the probes scanned several smaller regions that were stitched together into a final, roughly triangular region from $x=10~\text{cm}$ to $x=55~\text{cm}$ and $y=-15~\text{cm}$ to $y=18$ over approximately 7000 shots. For all measurements, the background magnetic field was $B_{0}=250~\text{G}$ and directed along $\hat{z}$ , and the ambient plasma was composed of $\text{H}^{+1}$ with an initial electron density of $n_{e0}\approx 1.5\times 10^{13}~\text{cm}^{-3}$ , electron temperature $T_{e0}\approx 10~\text{eV}$ , and ion temperature $T_{i0}\approx 1~\text{eV}$ (see Figure 2). Typical parameters are listed in Table 1.
The probe measurements were highly repeatable. Each location in a plane was repeated three times. The resulting time-dependent value (magnetic field or electrostatic potential) $F(t)$ was found to be within 5% of the mean value at that time, i.e., $F(t)=\langle F(t)\rangle \pm 5\%$ . This held for each location that was measured.
Figure 3 combines these $x$ – $z$ and $x$ – $y$ planes into a composite plot at time $t=0.5~\unicode[STIX]{x03BC}\text{s}$ for the $z$ -component of the relative magnetic field $\unicode[STIX]{x0394}B_{z}=B_{z}-B_{0}$ and the electrostatic potential $\unicode[STIX]{x1D6F7}$ . Features from each plane are well-aligned, again indicating that the individual measurements are very repeatable over thousands of laser shots. The formation of a fully expelled diamagnetic cavity and leading magnetic compression is clearly visible in $B_{z}$ . The cavity has an oblong shape, extending ${\sim}20~\text{cm}$ in both $y$ and $z$ with a maximum extend at this time of ${\sim}15~\text{cm}$ in $x$ . At the same time, there is a positive potential of $\unicode[STIX]{x1D6F7}\approx 300~\text{V}$ ahead of the magnetic compression that quickly goes to $\unicode[STIX]{x1D6F7}\approx -300~\text{V}$ at the edge of the magnetic cavity.
Figure 4 shows a time series of surface plots of $B_{z}$ in the $x$ – $z$ plane. A fully expelled magnetic cavity is led by a magnetic compression that reaches its peak value $B_{z}/B_{0}=1.7$ at $t\approx 0.5~\unicode[STIX]{x03BC}\text{s}$ , at which point it is moving at $v_{0}=250~\text{km}\cdot \text{s}^{-1}$ . This corresponds to an Alfvénic Mach number of $M_{A}=v_{0}/v_{A}=1.8$ , where the Alfvén speed $v_{A}=140~\text{km}\cdot \text{s}^{-1}$ is calculated for the ambient plasma. The cavity itself reaches its maximum size of 17 cm in $x$ shortly thereafter, and then stagnates at this distance while the compression continues to propagate at $M_{A}=1.5$ . Over the next ${\sim}1~\unicode[STIX]{x03BC}\text{s}$ , the magnetic field diffuses back into the cavity, starting with the cavity edges nearest to the target. This diffusion process results in a long-lived cavity elongated along the background magnetic field, so that the last segment of the cavity to collapse is a narrow strip extending along $z$ at the leading edge. Simultaneously, measurements in the $x$ – $y$ plane indicate that the magnetic compression propagates out to the edge of the LAPD ( $x=60~\text{cm}$ ) while gyrating upwards ( $y>0$ ), consistent with the compression being carried by ions.
We note that the cavity still collapses approximately an order of magnitude faster than the classical (Spitzer) or Bohm magnetic diffusion time $\unicode[STIX]{x1D70F}_{m}=l^{2}/\unicode[STIX]{x1D702}$ , where $l$ is the gradient magnetic scale length on the order of a few cm and $\unicode[STIX]{x1D702}$ is the diffusivity. At the time of collapse, the laser plasma is mostly confined within the magnetic cavity and has a density $n_{e}\approx 2.5\times 10^{12}$ , temperature $T_{e}\approx 10~\text{eV}$ , and average ionization $Z\approx 1.5$ [Reference Schaeffer, Bondarenko, Everson, Clark, Constantin and Niemann21]. At these parameters, the Bohm diffusivity $\unicode[STIX]{x1D702}_{B}=k_{B}T_{e}/16eB_{0}\approx 25~\text{m}^{2}\cdot \text{s}^{-1}$ . The classical diffusivity parallel to the background field $\unicode[STIX]{x1D702}_{S,||}\approx 0.5\unicode[STIX]{x1D70C}_{S}/\unicode[STIX]{x1D707}_{0}\approx 18~\text{m}^{2}\cdot \text{s}^{-1}$ , while the perpendicular diffusivity $\unicode[STIX]{x1D702}_{S,\bot }=(\unicode[STIX]{x1D708}_{e}/\unicode[STIX]{x1D714}_{ce})^{2}\unicode[STIX]{x1D70C}_{S}/\unicode[STIX]{x1D707}_{0}\approx 0.03~\text{m}^{2}\cdot \text{s}^{-1}$ , where $\unicode[STIX]{x1D70C}_{S}=\unicode[STIX]{x1D70B}Ze^{2}m_{e}^{1/2}\ln \unicode[STIX]{x1D6EC}/(4\unicode[STIX]{x1D70B}\unicode[STIX]{x1D716}_{0})^{2}(k_{B}T_{e})^{3/2}$ is the Spitzer resistivity, $\unicode[STIX]{x1D708}_{e}$ is the collision frequency, and $\unicode[STIX]{x1D714}_{ce}$ is the gyrofrequency. Thus, the fastest (Bohm) diffusion time considered is $\unicode[STIX]{x1D70F}_{m}\approx 30~\unicode[STIX]{x03BC}\text{s}$ , which is much larger than observed ( $\unicode[STIX]{x1D70F}_{m}\approx 1~\unicode[STIX]{x03BC}\text{s}$ ).
Transverse components of $\boldsymbol{B}$ were also measured. Figure 5 shows a time series of the $B_{y}$ component of the magnetic field in the $x$ – $z$ plane. Large-amplitude magnetosonic waves ( $B_{y}/B_{0}\sim 0.25$ ) can be seen propagating away from the target. The waves are associated with the magnetic cavity and dissipate as the cavity collapses at late time.
From our 2D planes of vector magnetic field $\boldsymbol{B}$ and electrostatic potential $\unicode[STIX]{x1D6F7}$ , we can calculate the current density $\boldsymbol{J}=\unicode[STIX]{x1D6FB}\times \boldsymbol{B}$ and electrostatic electric field $\boldsymbol{E}=-\unicode[STIX]{x1D6FB}\unicode[STIX]{x1D6F7}$ , where we take $\text{d}\boldsymbol{E}/\text{d}t\sim 0$ (the electric fields are slowly changing relative to the rate at which signals are sampled). We can also estimate the charge density $\unicode[STIX]{x1D70C}=-\unicode[STIX]{x1D716}_{0}\unicode[STIX]{x1D6FB}^{2}\unicode[STIX]{x1D6F7}$ . The results are shown in Figures 6 ( $x$ – $z$ plane) and 7 ( $x$ – $y$ plane), both at time $t=0.5~\unicode[STIX]{x03BC}\text{s}$ . Like Figure 4, Figure 6(a) shows a large magnetic cavity for $x\lesssim 15~\text{cm}$ . Outside of the cavity, the magnetic compression is dominantly directed along $+\hat{z}$ , which is the direction of the background field $B_{0}$ . At the same time, Figure 6(c) shows that the transition from $B_{z}=0$ in the cavity to $B_{z}>B_{0}$ outside the cavity is associated with a large, negative (into-the-plane) current density $J_{y}\approx -200~\text{A}\cdot \text{cm}^{-2}$ . A smaller amplitude current density ( $J_{y}\approx 30~\text{A}\cdot \text{cm}^{-2}$ ) is associated with the leading edge of the magnetic compression. The compression is also associated with an outward radially directed electric field of magnitude $|\boldsymbol{E}|\approx 100~\text{V}\cdot \text{cm}^{-1}$ , which reverses sign near the peak of the compression and grows to $|\boldsymbol{E}|\approx 300~\text{V}\cdot \text{cm}^{-1}$ near the cavity edge, as shown in Figure 6(b). The corresponding charge density $\unicode[STIX]{x1D70C}$ is shown in Figure 6(d), which indicates that there is a net positive charge coincident with the magnetic compression. Lineouts at $z=0$ from each of these quantities are shown in Figure 6(e).
These features are also reproduced in the $x$ – $y$ plane (Figure 7). Additionally, Figure 7(c) clearly shows the directionality of the diamagnetic current that supports the magnetic cavity. Together, the features in Figures 6 and 7 are consistent with a simple model of the piston–ambient plasma interaction. An initial radial inwardly directed ambipolar electric field is created between the relatively unmagnetized laser-plasma ions and magnetized electrons. This field drives $\boldsymbol{E}\times \boldsymbol{B}$ drifts of the electrons, which establishes a clockwise azimuthal diamagnetic current. The current is also supported by electron pressure gradient drifts ( $\unicode[STIX]{x1D6FB}P\times \boldsymbol{B}$ ) inherent to the laser-plasma profile. Concurrently, the pile-up of ions (relative to the ambient plasma) at the leading edge creates an outwardly directed electric field, which drives an oppositely directed azimuthal current that acts to increase (compress) the magnetic field.
4 Discussion and conclusions
The results of Section 3 show that highly repeatable, detailed and volumetric electrostatic potential and magnetic field datasets can be acquired by combining a high-repetition-rate laser and the LAPD. This in turn allows corresponding quantities of the electrostatic electric field, charge density and current density to also be calculated. Additionally, localized, volumetric measurements of the plasma density and temperature can be acquired with Langmuir probes or Thomson scattering, both of which have previously been fielded on the LAPD for laser experiments[Reference Niemann, Gekelman, Constantin, Everson, Schaeffer, Clark, Winske, Zylstra, Pribyl, Tripathi, Larson, Glenzer and Bondarenko22, Reference Schaeffer, Constantin, Bondarenko, Everson and Niemann23]. Large-scale structure or charge-state evolution of laser-plasma or ambient ions through self-emission can also be imaged with high-repetition, filtered fast-gate cameras[Reference Heuer, Schaeffer, Knall, Constantin, Hofer, Vincena, Tripathi and Niemann20]. Finally, the measurements shown here were confined to the immediate vicinity of the target, but they can be easily extended to regions farther downstream to study, for example, propagating waves.
This high-repetition platform thus provides a rich testbed for exploring the interaction between super-Alfvénic laser plasmas and magnetized ambient plasmas relevant to laboratory astrophysics. Indeed, the experiments presented here were modeled after previous low-repetition experiments on the LAPD that explored perpendicular magnetized collisionless shocks[Reference Niemann, Gekelman, Constantin, Everson, Schaeffer, Bondarenko, Clark, Winske, Vincena, Van Compernolle and Pribyl24, Reference Schaeffer, Winske, Larson, Cowee, Constantin, Bondarenko, Clark and Niemann25]. In this setup, the laser plasma acts as a supersonic piston to sweep up and accelerate ambient ions until they form a shock[Reference Bondarenko, Schaeffer, Everson, Clark, Lee, Constantin, Vincena, Van Compernolle, Tripathi, Winske and Niemann26]. While the higher-energy (though similar intensity) laser used in previous experiments allows for more energetic pistons, a high-repetition-rate laser allows for a more efficient exploration of the parameter space (background density and magnetic field, ambient gas fill, piston speed, etc.) for shock physics.
Other applications of this platform are currently being pursued. Fast-gate imaging of the laser plasma shows the formation and evolution of flute-like, Rayleigh–Taylor or large-Larmor-radius magnetic instabilities[Reference Heuer, Schaeffer, Knall, Constantin, Hofer, Vincena, Tripathi and Niemann20, Reference Huba, Lyon and Hassam27]. Future work will utilize thousands of shots to correlate fluctuations in the magnetic and electric fields and determine the instability growth rate[Reference Collette and Gekelman28]. Kinetic-scale magnetospheres are also possible to explore by coupling the laser plasma with an ion-scale ( ${\sim}10~\text{cm}$ ) magnetic dipole field[Reference Cruz, Alves, Bamford, Bingham, Fonseca and Silva29]. Of particular interest is the dynamics and 3D structure of the interaction between a super-Alfvénic flow and the dipole field, which can be mapped out at high resolution over thousands of shots. Finally, the large axial size of the LAPD, combined with the high-repetition-rate laser, provides a unique opportunity to study the waves and instabilities associated with parallel magnetized collisionless shocks. Here, the laser-plasma piston streams along the background field and excites electromagnetic ion beam instabilities, which can be scanned over multiple planes along the length of the machine. Such experiments are currently ongoing[Reference Heuer, Weidl, Dorst, Schaeffer, Bondarenko, Tripathi, Van Compernolle, Vincena, Constantin and Niemann30].
Acknowledgements
This work was supported by the DTRA under Contract No. HDTRA1-12-1-0024, and the DOE under Contract Nos. DE-SC0006538 and DE-SC0017900. Thanks to Brent Dane (MIC) for helping to commission the Peening laser system, and Andi Henning for facilitating the loan of the Peening laser from the Space and Naval Warfare Systems Command. Experiments were performed at the UCLA Basic Plasma Science Facility (BaPSF), supported by the DOE and NSF.