Hostname: page-component-78c5997874-v9fdk Total loading time: 0 Render date: 2024-11-10T06:15:41.135Z Has data issue: false hasContentIssue false

What Is the Best Method? Recovery of Methicillin-Resistant Staphylococcus aureus and Extended-Spectrum β-Lactamase–Producing Escherichia coli from Inanimate Hospital Surfaces

Published online by Cambridge University Press:  10 May 2016

Tânia Claro*
Affiliation:
Department of Clinical Microbiology, Education, and Research Centre, Royal College of Surgeons in Ireland, Beaumont Hospital, Dublin 9, Ireland
Sandra Galvin
Affiliation:
Department of Clinical Microbiology, Education, and Research Centre, Royal College of Surgeons in Ireland, Beaumont Hospital, Dublin 9, Ireland
Orla Cahill
Affiliation:
School of Electronic Engineering and National Centre for Plasma Science Technology, Dublin City University, Dublin 9, Ireland
Deirdre Fitzgerald-Hughes
Affiliation:
Department of Clinical Microbiology, Education, and Research Centre, Royal College of Surgeons in Ireland, Beaumont Hospital, Dublin 9, Ireland
Stephen Daniels
Affiliation:
School of Electronic Engineering and National Centre for Plasma Science Technology, Dublin City University, Dublin 9, Ireland
Hilary Humphreys
Affiliation:
Department of Clinical Microbiology, Education, and Research Centre, Royal College of Surgeons in Ireland, Beaumont Hospital, Dublin 9, Ireland Department of Microbiology, Beaumont Hospital, Dublin 9, Ireland
*
Department of Clinical Microbiology, Education, and Research Centre, Royal College of Surgeons in Ireland, Beaumont Hospital, Dublin 9, Ireland (tpedrosaclaro@rcsi.ie).

Extract

Environmental sampling in hospitals, when required, needs to be reliable. We evaluated different methods of sampling methicillin-resistant Staphylococcus aureus and extended-spectrum β-lactamase–producing Escherichia coli on 5 materials of the hospital setting. Petrifilms and contact plates were superior to swabs for all of the surfaces studied.

Infect Control Hosp Epidemiol 2014;35(7):869–871

Type
Concise Communication
Copyright
© 2014 by The Society for Healthcare Epidemiology of America. All rights reserved.

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Hota, B. Contamination, disinfection, and cross-colonization: are hospital surfaces reservoirs for nosocomial infection? Clin Infect Dis 2004;39(8):11821189.Google ScholarPubMed
2. Bhalla, A, Pultz, NJ, Gries, DM, et al. Acquisition of nosocomial pathogens on hands after contact with environmental surfaces near hospitalized patients. Infect Control Hosp Epidemiol 2004;25(2):164167.Google Scholar
3. Dancer, SJ. The role of environmental cleaning in the control of hospital-acquired infection. J Hosp Infect 2009;73(4):378385.CrossRefGoogle ScholarPubMed
4. Sehulster, L, Chinn, RY; CDC; HICPAC. Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC). MMWR Recomm Rep 2003;52(RR-10):142.Google ScholarPubMed
5. Dalmaso, G, Bini, M, Paroni, R, Ferrari, M. Qualification of high-recovery, flocked swabs as compared to traditional rayon swabs for microbiological environmental monitoring of surfaces. PDA J Pharm Sci Technol 2008;62(3):191199.Google Scholar
6. Lutz, JK, Crawford, J, Hoet, AE, Wilkins, JR 3rd, Lee, J. Comparative performance of contact plates, electrostatic wipes, swabs and a novel sampling device for the detection of Staphylococcus aureus on environmental surfaces. J Appl Microbiol 2013;115(1):171178.Google Scholar
7. Hooker, EA, Allen, S, Gray, L, Kaufman, C. A randomized trial to evaluate a launderable bed protection system for hospital beds. Antimicrob Resist Infect Control 2012;1(1):27.Google Scholar
8. Burke, L, Humphreys, H, Fitzgerald-Hughes, D. The revolving door between hospital and community: extended-spectrum beta-lactamase-producing Escherichia coli in Dublin. J Hosp Infect 2012;81(3):192198.Google Scholar
9. McNicholas, WHJS, Humphreys, H, Fitzgerald-Hughes, D. Susceptibility of Staphylococcus aureus isolates causing bloodstream infection to the antimicrobial peptide LL-37. Open J Med Microbiol 2013;3(1):8083.Google Scholar
10. Lemmen, SW, Hafner, H, Zolldann, D, Stanzel, S, Lutticken, R. Distribution of multi-resistant gram-negative versus gram-positive bacteria in the hospital inanimate environment. J Hosp Infect 2004;56(3):191197.CrossRefGoogle ScholarPubMed