Hostname: page-component-78c5997874-s2hrs Total loading time: 0 Render date: 2024-11-14T04:45:20.635Z Has data issue: false hasContentIssue false

Assessment of Catheter-Associated Infection Risk with the Hickman Right Atrial Catheter

Published online by Cambridge University Press:  02 January 2015

Peter C. Fuchs*
Affiliation:
Departments of Hospital Epidemiology, Surgery and Medicine, St. Vincent Hospital and Medical Center, Portland, Oregon
Marie E. Gustafson
Affiliation:
Departments of Hospital Epidemiology, Surgery and Medicine, St. Vincent Hospital and Medical Center, Portland, Oregon
James T. King
Affiliation:
Departments of Hospital Epidemiology, Surgery and Medicine, St. Vincent Hospital and Medical Center, Portland, Oregon
Patrick T. Goodall
Affiliation:
Departments of Hospital Epidemiology, Surgery and Medicine, St. Vincent Hospital and Medical Center, Portland, Oregon
*
Department of Hospital Epidemiology, St. Vincent Hospital and Medical Center, Portland, OR 97225

Abstract

One hundred fifty Hickman right atrial catheters were inserted into 143 patients and were followed prospectively until removal. Primary indications for their use were: cancer chemotherapy (45), parenteral nutrition (35), antibiotic therapy (63), and miscellaneous (7). The overall catheter-associated infection rate was 12.0%. Since the mean duration of catheterization was 125 days, the infection/duration rate was 1.0/1,000 days of use. The risk of infection differed significantly according to the primary indication for catheterization: parenteral nutrition > antibiotic therapy > cancer chemotherapy. The increased risk of catheter-associated infection attributable to duration of catheterization was additive, and the per day risk of such infections remained constant regardless of duration. Nearly two-thirds of patients were discharged home with catheters in place, without adversely affecting infection risk.

Type
Original Articles
Copyright
Copyright © The Society for Healthcare Epidemiology of America 1984

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Broviac, JW, Cole, JJ, Scribner, BH, A silicone rubber atrial catheter for prolonged parenteral alimentation. Surg Gynecol Obstet 1973;36:602606.Google Scholar
2.Hickman, RO, Buckner, CD, Clift, RA, et al: A modified right atrial catheter for access to the venous system in marrow transplant recipients. Surg Gynecol Obstet 1979;148:871875.Google Scholar
3.Blacklock, HA, Pilla, MV, Hill, RS, et al: Use of modified subcutaneous right-atrial catheter for venous access in bulemia patients. Lancet 1980;1:993994.Google Scholar
4.Larson, EB, Wooding, M, Hickman, RO, Infectious complications of right atrial catheters used for venous access in patients receiving intensive chemotherapy. Surg Gynecol Obstet 1981;153:369373.Google Scholar
5.Abrahm, JL, Mullen, JL, A prospective study of prolonged central venous access in leukemia. JAMA 1982;248:28682873.Google Scholar
6.Heimbach, DM, Ivey, TD, Technique for placement of a permanent home hyperalimentation catheter. Surg Gynecol Obstet 1976;143:635.Google Scholar
7.Maki, DG, Weise, CE, Sarafin, HW, A semiquantitative culture method for identifying intravenous-related infections. N Engl J Med 1977;296:13051309.Google Scholar
8.Snydman, DR, Murray, SA, Kornfeld, SJ, et al: Total parenteral nutrition-related infections. Prospective epidemiologic study using semiquantitative methods. Am J Med 1982;73:695699.Google Scholar
9.Shapiro, ED, Wald, ER, Nelson, KA, et al: Broviac catheter-related bacteremia in oncology patients. Am J Dis Child 1982;136:679681.Google Scholar
10.Begala, JE, Maher, K, Cherry, JD, Risk of infection associated with the use of Broviac and Hickman catheters. Am J Infect Control 1981;10:1723.Google Scholar
11.Maki, DG, Goldmann, DA, Rhame, FS, Infection control in intravenous therapy. Ann Intern Med 1973;79:867887.Google Scholar
12.Fuchs, PC, Indwelling intravenous polyethylene catheters. Factors influencing the risk of microbial colonization and sepsis. JAMA 1971;216:14471450.CrossRefGoogle ScholarPubMed