Hostname: page-component-cd9895bd7-q99xh Total loading time: 0 Render date: 2024-12-26T06:53:12.116Z Has data issue: false hasContentIssue false

Milkline vacuum stability in milking machine installations

Published online by Cambridge University Press:  22 November 2002

ODD RøNNINGEN
Affiliation:
TINE Norwegian Dairies BA, P.O. Box 58, N-1431 Ås, Norway

Abstract

Transient vacuum drops in the milkline during one ordinary milking were recorded as a measure of vacuum stability in milking installations on 184 Norwegian dairy farms in the summer of 1997. An association between the frequency of vacuum drops and technical data including milkline diameter, length and slope, number of milking units and effective reserve was demonstrated. The direct connection between the transient vacuum drop and its cause could be established for most drops during milking observations. A high frequency of transient vacuum drops in the milkline was associated with a high level of mastitis and a high new infection rate as inferred from changes in somatic cell counts for individual cows. The frequency of vacuum drops during one milking is only a rough indication of the long-term vacuum stability in a specific installation, and must be interpreted with care. The dimensions and slope of the milkline and the effective reserve probably give as good information about the installation's ability to maintain a stable vacuum.

Type
Original article
Copyright
Proprietors of Journal of Dairy Research 2002

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)