Hostname: page-component-cd9895bd7-mkpzs Total loading time: 0 Render date: 2024-12-27T11:04:23.606Z Has data issue: false hasContentIssue false

An alternative approach to mixed hearing loss in otosclerosis: stapes surgery combined with an active middle-ear implant

Published online by Cambridge University Press:  12 June 2018

H R F Powell
Affiliation:
Hearing Implant Centre, Guy's and St Thomas’ NHS Foundation Trust, London, UK
I Pai
Affiliation:
Hearing Implant Centre, Guy's and St Thomas’ NHS Foundation Trust, London, UK
H Ghulam
Affiliation:
Hearing Implant Centre, Guy's and St Thomas’ NHS Foundation Trust, London, UK
D Jiang*
Affiliation:
Hearing Implant Centre, Guy's and St Thomas’ NHS Foundation Trust, London, UK
*
Address for correspondence: Prof Dan Jiang, Hearing Implant Centre, 2nd floor Lambeth Wing, St Thomas’ Hospital, Westminster Bridge Road, London SE1 7EH, UK E-mail: dan.jiang@kcl.ac.uk

Abstract

Objective:

To report a novel management strategy for mixed hearing loss in advanced otosclerosis.

Methods:

A 50-year-old male was referred to St Thomas’ Hearing Implant Centre with otosclerosis; he was no longer able to wear conventional hearing aids because of recurrent otitis externa. The patient underwent short process incus vibroplasty (using the Med-El Vibrant Soundbridge device), followed at a suitable interval (six weeks) by stapes surgery. The main outcome measures were: pure tone audiometry, functional gain and monosyllabic word recognition scores.

Results:

Post-operative pure tone audiometry showed a reduction of the mean air–bone gap from 55 dB HL to 20 dB HL. The residual mixed hearing loss was rehabilitated with the Vibrant Soundbridge, with an average device gain of 32 dB. The monosyllabic word recognition scores in quiet at 65 dB improved from 37 to 100 per cent when using the Vibrant Soundbridge at six months after switch-on of the device.

Conclusion:

Stapedotomy in conjunction with incus short process vibroplasty (i.e. inner-ear vibroplasty) is a safe and promising procedure for managing advanced otosclerosis with mixed hearing loss in selected patients.

Type
Short Communications
Copyright
Copyright © JLO (1984) Limited 2018 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

Presented at the 6th International Congress on Bone Conduction Hearing and Related Technologies, 17−20 May 2017, Nijmegen, the Netherlands.

References

1Hentschel, MA, Huizinga, P, van der Velden, DL, Wegner, L, Bittermann, AJ, Vander Heijden, GJ et al. Limited evidence of the effect of sodium fluoride on deterioration of hearing loss in patients with otosclerosis: a systematic review of the literature. Otol Neurotol 2014;35:1052–7.CrossRefGoogle ScholarPubMed
2Burrell, SP, Cooper, HC, Proops, DW. The bone anchored hearing aid-the third option for otosclerosis. J Laryngol Otol 1996;21:31–7.CrossRefGoogle ScholarPubMed
3Quaranta, N, Bartoli, R, Lopriore, A, Fernandez-Vega, S, Giagnotti, F, Quaranta, A. Cochlear implantation in otosclerosis. Otol Neurotol 2005;26:983–7.CrossRefGoogle ScholarPubMed
4Schmuziger, N, Schimmann, F, Wengen, D, Patscheke, J, Probst, R. Long-term assessment after implantation of the Vibrant Soundbridge device. Otol Neurotol 2006;27:183–8.CrossRefGoogle ScholarPubMed
5Mosnier, I, Sterkers, O, Boucarra, D, Labassi, S, Bebear, JP, Bordure, P et al. Benefit of the Vibrant Soundbridge device in patients implanted for 5 to 8 years. Ear Hear 2008;29:281–4.CrossRefGoogle ScholarPubMed
6Schraven, SP, Dalhoff, E, Wildenstein, D, Hagen, R, Gummer, AW, Mlynski, R. Alternative fixation of an active middle ear implant at the short incus process. Audiol Neurotol 2014;19:111.CrossRefGoogle ScholarPubMed
7Mlynski, R, Dalhoff, E, Heyd, A, Wildenstein, D, Rak, K, Radeloff, A et al. Standardized active middle-ear implant coupling to the short incus process. Otol Neurotol 2015;36:1390–8.CrossRefGoogle Scholar
8Dumon, T. Vibrant Soundbridge middle ear implant in otosclerosis: technique - indication. Adv Otorhinolaryngol 2007;65:320–2.Google ScholarPubMed
9Kontorinis, G, Lenarz, T, Mojallal, H, Hinze, AL, Schwab, B. Power stapes: an alternative method for treating hearing loss in osteogenesis imperfecta? Otol Neurotol 2011;32:589–95.CrossRefGoogle ScholarPubMed