Crossref Citations
This article has been cited by the following publications. This list is generated based on data provided by Crossref.
Tong, Y. C.
Black, R. C.
Clark, G. M.
Forster, I. C.
Millar, J. B.
O'Loughlin, B. J.
and
Patrick, J. F.
1979.
A preliminary report on a multiple-channel cochlear implant operation.
The Journal of Laryngology & Otology,
Vol. 93,
Issue. 7,
p.
679.
Klinke, Rainer
and
Hartmann, Rainer
1979.
Physiologische Grundlagen einer H�rprothese.
Archives of Oto-Rhino-Laryngology,
Vol. 223,
Issue. 1,
p.
77.
Forster, Ian C.
1981.
Theoretical design and implementation of a transcutaneous, multichannel stimulator for neural prosthesis applications.
Journal of Biomedical Engineering,
Vol. 3,
Issue. 2,
p.
107.
Tong, Y. C.
Clark, G. M.
Dowell, R. C.
Martin, L. F. A.
Seligman, P. M.
and
Patrick, J. F.
1981.
A Multiple-Channel Cochlear Implant and Wearable Speech-Processor:An Audiological Evaluation.
Acta Oto-Laryngologica,
Vol. 92,
Issue. 1-6,
p.
193.
Clark, Graeme M.
Tong, Yit Chow
Martin, Lois F.
Busby, Peter A.
Dowell, Richard C.
Seligman, Peter M.
and
Patrick, James F.
1981.
A Multiple-Channel Cochlear Implant: An Evaluation using Nonsense Syllables.
Annals of Otology, Rhinology & Laryngology,
Vol. 90,
Issue. 3,
p.
227.
Black, Raymond C.
Clark, Graeme M.
and
Patrick, James F.
1981.
Current Distribution Measurements Within the Human Cochlea.
IEEE Transactions on Biomedical Engineering,
Vol. BME-28,
Issue. 10,
p.
721.
Plant, Geoff L
1982.
Tactile Perception by the Profoundly Deaf Speech and environmental sounds.
British Journal of Audiology,
Vol. 16,
Issue. 4,
p.
233.
Hochmair‐Desoyer, Ingeborg J.
Hochmair, Erwin S.
and
Burian, K.
1983.
DESIGN AND FABRICATION OF MULTIWIRE SCALA TYMPANI ELECTRODESa.
Annals of the New York Academy of Sciences,
Vol. 405,
Issue. 1,
p.
173.
Glass, Itzhak
1983.
Tuning characteristics of cochlear nucleus units in response to electrical stimulation of the cochlea.
Hearing Research,
Vol. 12,
Issue. 2,
p.
223.
Clark, G. M.
Shepherd, R. K.
Patrick, J. F.
Black, R. C.
and
Tong, Y. C.
1983.
DESIGN AND FABRICATION OF THE BANDED ELECTRODE ARRAYa.
Annals of the New York Academy of Sciences,
Vol. 405,
Issue. 1,
p.
191.
Parkins, Charles W.
1983.
Cochlear Implant: A Sensory Prosthesis Frontier.
IEEE Engineering in Medicine and Biology Magazine,
Vol. 2,
Issue. 2,
p.
18.
Black, R. C.
Clark, G. M.
O'leary, S. J.
and
Walters, C.
1983.
Intracochlear Electrical Stimulation of Normal and DEAF CATS Investigated Using Brainstem Response Audiometry.
Acta Oto-Laryngologica,
Vol. 95,
Issue. sup399,
p.
5.
Clark, G. M.
Dowell, R. C.
Pyman, B. C.
Brown, A. M.
Webb, R. L.
Tong, Y. C.
Bailey, Q.
and
Seligman, P. M.
1984.
CLINICAL TRIAL OF A MULTI‐CHANNEL COCHLEAR PROSTHESIS: RESULTS ON 10 POSTLINGUALLY DEAF PATIENTS.
Australian and New Zealand Journal of Surgery,
Vol. 54,
Issue. 6,
p.
519.
Brennan, Warwick J.
and
Clark, Graeme M.
1985.
An animal model of acute otitis media and the histopathological assessment of a cochlear implant in the cat.
The Journal of Laryngology & Otology,
Vol. 99,
Issue. 9,
p.
851.
Joseph, Anthony B.
1985.
Design considerations for the brain-machine interface.
Medical Hypotheses,
Vol. 17,
Issue. 3,
p.
191.
O'Leary, S.J.
Black, R.C.
and
Clark, G.M.
1985.
Current distributions in the cat cochlea: A modelling and electrophysiological study.
Hearing Research,
Vol. 18,
Issue. 3,
p.
273.
Clifford, A. R.
and
Gibson, W. P. R.
1987.
Anatomy of the round Window with Respect to Cochlear Implant Surgery.
Annals of Otology, Rhinology & Laryngology,
Vol. 96,
Issue. 1_suppl,
p.
17.
Lukies, P. M.
Tong, Y. C.
and
Clark, G. M.
1987.
Current Distributions Produced by the Banded Electrode Array: An Experimental Study Conducted with a Tank Model.
Annals of Otology, Rhinology & Laryngology,
Vol. 96,
Issue. 1_suppl,
p.
24.
2003.
Cochlear Implants.
p.
595.
2003.
Cochlear Implants.
p.
454.