Hostname: page-component-78c5997874-ndw9j Total loading time: 0 Render date: 2024-11-10T15:18:07.705Z Has data issue: false hasContentIssue false

Congenital stapes footplate fixation associated with duplication of lobule

Published online by Cambridge University Press:  08 March 2006

Ashwani Sethi
Affiliation:
Department of ENT and Head and Neck Surgery, Maulana Azad Medical College and Associated L N Hospital, New Delhi, India
Deepika Sareen
Affiliation:
Department of ENT and Head and Neck Surgery, Maulana Azad Medical College and Associated L N Hospital, New Delhi, India
Ravi Meher
Affiliation:
Department of ENT and Head and Neck Surgery, Maulana Azad Medical College and Associated L N Hospital, New Delhi, India
Piyush Nath
Affiliation:
Department of ENT and Head and Neck Surgery, Maulana Azad Medical College and Associated L N Hospital, New Delhi, India

Abstract

We report the case of an 18-year-old male patient who presented to us with unilateral conductive hearing loss with duplication of the lobule. An exploratory tympanotomy revealed stapes footplate fixation. A stapedotomy with insertion of a Teflon piston was performed with improvement in his hearing. We believe this is the first reported case of such an abnormality.

Type
Research Article
Copyright
© 2005 Royal Society of Medicine Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)