Hostname: page-component-cd9895bd7-dzt6s Total loading time: 0 Render date: 2024-12-27T06:22:24.324Z Has data issue: false hasContentIssue false

Does coronavirus disease 2019 affect peripheral and central auditory systems? Matched group cross-sectional study and six-month follow up

Published online by Cambridge University Press:  08 March 2024

Merve Deniz-Sakarya*
Affiliation:
Department of Audiology, Faculty of Health Sciences, Baskent University, Ankara, Turkey
İrfan Yorulmaz
Affiliation:
Department of Otorhinolaryngology—Head and Neck Surgery, Faculty of Medicine, Ankara University, Ankara, Turkey
*
Corresponding author: Merve Deniz-Sakarya; Email: mervedeniz91@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

Objective

This study aimed to compare the peripheral-to-central auditory systems of people with coronavirus disease 2019 to a well-matched control group and examine the long-term effects of coronavirus disease 2019 on the auditory system.

Method

Participants who were outpatients of coronavirus disease 2019 (n = 30) were compared with a well-matched control group (n = 30). Behavioural and electrophysiological tests were performed, and tests were repeated at six months in the coronavirus disease 2019 group.

Results

Statistically significant differences were observed in the right ear at 10 kHz (p = 0.007) and 12.5 kHz (p = 0.028), and in the left ear at 10 kHz (p = 0.040) and 12.5 kHz (p = 0.040) between groups. The groups had no difference regarding the other audiological test results (p > 0.05).

Conclusion

Extended high-frequency thresholds were affected in the coronavirus disease 2019 patients. No other findings indicated that the peripheral-to-central auditory system was affected. The effect on extended high-frequency thresholds appeared permanent, but no clinically significant new, late-onset auditory system effects were observed.

Type
Main Article
Creative Commons
Creative Common License - CCCreative Common License - BYCreative Common License - NCCreative Common License - ND
This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives licence (http://creativecommons.org/licenses/by-nc-nd/4.0), which permits non-commercial re-use, distribution, and reproduction in any medium, provided that no alterations are made and the original article is properly cited. The written permission of Cambridge University Press must be obtained prior to any commercial use and/or adaptation of the article.
Copyright
Copyright © The Author(s), 2024. Published by Cambridge University Press on behalf of J.L.O. (1984) LIMITED

Introduction

Several neurological and neuro-otological manifestations have been reported in association with coronavirus disease 2019 (Covid-19).Reference Collantes, Espiritu, Sy, Anlacan and Jamora1Reference Eravci, Alafifi, Dündar, Korkmaz, Demirbaş and Vatansev3 In particular, the number of cases or case series of sudden sensorineural hearing loss associated with Covid-19 has been widely reported in the literature.Reference Umashankar, Prakash and Prabhu4 While some studies have found an increase in the incidence of hearing loss during the pandemic compared to the pre-pandemic period,Reference Wagatsuma, Daimaru, Deng and Chen5 controlled studies investigating the effect of Covid-19 on the hearing system have shown inconsistent results. Some controlled studies have suggested a decrease in high-frequency (4–8 kHz) hearing thresholds during and shortly after a positive reverse transcription polymerase chain reaction.Reference Daikhes, Karneeva, Machalov, Kuznetcov, Sapozhnikov and Balakina6Reference Tan, Cengiz, Demir, Demirel, Çolak and Karakaş12 In some studies, extended high-frequency thresholds were also included in the analysis, and an effect of Covid-19 on the 10–16 kHz thresholds was shown.Reference Gedik, Hüsam, Başöz, Tas and Aksoy8,Reference Öztürk, Kavruk and Aykul10,Reference Emekci, Dündar, Kirazlı, Men Kılınç, Cengiz and Karababa13 In contrast to these findings, several other studies detected no statistical or clinical differences in hearing thresholds compared to control measurements.Reference Dror, Kassis-Karayanni, Oved, Daoud, Eisenbach and Mizrachi14Reference Yıldız19 However, most of these cross-sectional studies examined only short-term auditory effects.

Although the underlying mechanisms are not fully known, it has been reported in the literature that severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) may be neurotropic.Reference Zhou, Kang, Li and Zhao20 However, only a few studies investigating the relationship between Covid-19 and the auditory system have included audiological tests that can provide information about the central auditory system. In studies comparing the auditory brainstem response (ABR) findings of individuals with Covid-19 with those of a control group, no difference could be detected for the absolute latency and amplitude of waves I, III and V.Reference Gedik, Hüsam, Başöz, Tas and Aksoy8,Reference Dror, Kassis-Karayanni, Oved, Daoud, Eisenbach and Mizrachi14 Only one study showed a significant difference between the groups in absolute latency of waves I, III and V, which was interpreted as a peripheral hearing loss effect.Reference Öztürk, Kavruk and Aykul10

The effect of Covid-19 on the peripheral-to-central auditory system still needs to be clarified, as cross-sectional studies in the literature have been conducted using limited audiological test tools (often only with pure tone audiometry and/or otoacoustic emissions) and have presented inconsistent results. Furthermore, the long-term effects of Covid-19 on hearing have not been sufficiently investigated. This study aimed to examine the peripheral-to-central auditory systems of patients following their recovery from Covid-19 with a comprehensive audiological test battery and to reveal the long-term auditory effects of the disease.

Materials and methods

This study involves data collected between August 2021 and September 2022 at the Audiology Unit of the ENT Department, Faculty of Medicine, Ankara University. The study was conducted following the principles of the Declaration of Helsinki, and approval was granted by the Ethics Committee of Ankara University (Date: 12 August 2021/No: İ7-495-21).

The study group consisted of 30 Covid-19 patients (11 males and 19 females), with a mean age of 34.57 ± 11.56 years and a control group of 30 healthy individuals without Covid-19 (11 males and 19 females), with a mean age of 34.50 ± 11.83 years. The two groups were matched on age range and gender (Table 1). Covid-19 was diagnosed by reverse transcription polymerase chain reaction. None of the patients required hospitalisation. The audiological assessments were performed 46.10 ± 16.53 days after the reverse transcription polymerase chain reaction diagnosis (minimum 39 days, maximum 89 days). Sixteen (53.33 per cent) patients with Covid-19 received favipiravir treatment, while the remaining 14 (46.67 per cent) had no antiviral treatment. The inclusion criteria were normal otoscopic findings and normal tympanogram (Type A). The exclusion criteria were history of ear surgery, noise exposure, neurological and/or psychiatric disease, ototoxic drug use, self-report hearing loss and tinnitus before Covid-19, and being treated in intensive care for Covid-19.

Table 1. Characteristics of participants

SD = standard deviation

Instruments: questionnaire

Information about the demographic characteristics of the participants (e.g. age, gender) and their Covid-19-related hearing and/or communication difficulties (e.g. reduced hearing, difficulty understanding speech, tinnitus) was collected.

Behavioural tests

Pure tone audiometry and extended high-frequency audiometry

Pure tone air and bone conduction thresholds were recorded using an Interacoustic AC 40 clinical audiometer (Assens, Denmark) using Telephonics TDH-39 supra-aural headphones (Farmingdale, New York, USA) at 0.25–8 kHz frequencies. Bone conduction hearing thresholds were determined using a RadioEar B71 bone vibrator (Middelfart, Denmark) at 0.5–4 kHz frequencies. Extended high-frequency audiometry thresholds at 10–14 kHz frequencies were determined with an AC 40 Interacoustics clinical audiometer using Sennheiser HDA300 headphones (Wedemark, Germany). Thresholds were determined using the Hughson–Westlake method.

Speech audiometry and speech recognition in noise tests

Speech reception thresholds and speech recognition scores were calculated for each ear. In addition, speech recognition in noise tests were performed by simultaneously presenting a monosyllabic phonetically balanced word list at 40 dB sensation level and white noise at 40 dB sensation level to the subjects’ ipsilateral test ear.

Masking-level difference test

Masking-level difference is a behavioural test to detect lower brainstem lesions. Narrowband noise was presented continuously at 50 dB sensation level, while 500 Hz pure tone was presented in homophasic (S0N0) and antiphasic (SπN0) listening conditions starting at 70 dB HL. The masking-level difference score was obtained by calculating the difference between S0N0 and SπN0.

Electroacoustic and electrophysiological tests

Immitansmetric measures

Tympanometry and acoustic reflex threshold were performed using a GSI TympStar Pro middle ear analyser (Grason–Stadler, Eden Prairie, MN, USA). Tympanograms were obtained by presenting a 226 Hz probe tone at 85 dB SPL to the ear while the ear canal pressure was varied from +200 to −400 daPa. Acoustic reflex threshold was performed between 500 Hz and 4000 Hz frequencies, ipsilaterally and contralaterally.

Transient evoked oto-acoustic emissions

Transient evoked oto-acoustic emissions (TEOAE) was used to evaluate the integrity of the participants' inner ear outer hair cells. Transient evoked oto-acoustic emissions testing was performed with the Echoport ILO 292 USB-II, version 6 (Otodynamics, London, UK). signal-to-noise responses were recorded at 1, 1.4, 2, 2.8, and 4 kHz frequencies. Each record consists of an average of 260 sweeps. Wave reproducibility of 70 per cent and above and stimulus stability of 80 per cent and above were accepted in both measurements.

Auditory brainstem response and middle latency response

Auditory brainstem response (ABR) and middle latency response (MLR) were used to evaluate auditory pathways at the brainstem and midbrain levels. Interacoustics Eclipse EP 25 (Interacoustics, Middelfart, Denmark) was used for ABR and MLR recordings recorded in 2 channels: the disc electrodes were placed between the vertex and right mastoid for channel 1, and between the vertex and left mastoid for channel 2, with the forehead as ground. Electrode impedances were maintained below 5.0 kΩ. Stimuli were delivered via insert earphones for the right and left ear. The ABR test was recorded at 80 dB normal hearing level in rarefaction polarity, using 21.1 click stimuli per second, averaging up to 1000 sweeps. The bandpass filter range was adjusted at 30 Hz and 3000 Hz high-frequency cut-off, respectively. The MLR test was recorded at 70 dB normal hearing level in alternate polarity, using 7.1 rate of 500 Hz tone burst stimuli per second, averaging up to 1000 sweeps. The bandpass filter range is adjusted at high- and low-frequency cut-offs of 30 and 3000 Hz, respectively.

All statistical analyses were performed using SPSS version 22.0 (SPSS Inc., Chicago, IL, USA). To evaluate the normality of distribution Shapiro–Wilk test and, in order to assess equality of variances, Levene's test were used. Comparisons were analysed using either the independent samples t-test or the Mann–Whitney U test. The difference between the first and second measurements of the patient group was made with the dependent sample t-test or Wilcoxon signed rank text. All reported p-values are two-tailed, with a p-value ≤ 0.05 indicating statistical significance.

Results

Questionnaire results

After Covid-19, 8 out of 30 participants (26.7 per cent) reported at least one hearing or communication difficulty. Four participants (13.3 per cent) had more than one complaint. Five participants (16.6 per cent) reported difficulty understanding speech in noise, three participants (10 per cent) reported new-onset tinnitus, three participants (10 per cent) had annoyance with loud sounds, two participants (6.6 per cent) reported difficulty understanding speech in quiet, and two participants (6.6 per cent) reported fullness in the ear. In three (10 per cent) patients with Covid-19 and tinnitus, the onset of symptoms was within 5–7 days following diagnosis of Covid-19. At the first evaluation, the mean visual analogue scale (VAS) annoyance was 2.33 ± 1.53 (minimum 1, maximum 4), and the mean VAS-tinnitus loudness was 3.66 ± 1.53 (minimum 2, maximum 5).

Behavioural test results

No significant difference was observed between the two groups for 0.25–8 kHz air-conduction thresholds, pure tone average (PTA), and 0.5–4 kHz bone-conduction thresholds. However, a statistically significant difference was observed for extended high-frequency thresholds in right ears at 10 kHz (p = 0.007) and 12.5 kHz (p = 0.023), and in left ears at 10 kHz (p = 0.040) and 12.5 kHz (p = 0.040). Participants with a history of Covid-19 had higher extended high-frequency thresholds for the right and left ears (Table 2). No significant difference was found between groups in right speech-reception thresholds (p = 0.362), left speech-reception thresholds (p = 0.612), right speech-recognition scores (p = 0.068), left speech-recognition scores (p = 0.449), right speech-recognition scores in noise tests (p = 0.652) and left speech-recognition scores in noise tests (p = 0.380).

Table 2. Comparison of pure-tone and extended high-frequency audiometry test results in groups

U = Mann–Whitney U test; t = independent sample t-test; * significant difference (p < 0.05); PTA = pure tone average

In the masking-level difference test, the mean S0N0−SπN0 value was 10.53 ± 2.67 for the patient group and 10.80 ± 2.38 for the control group. There was no significant difference in masking-level difference score between groups (U = 489.5, p = 0.545).

Electroacoustic and electrophysiological test results

There was no statistically significant difference between the middle ear peak pressure, static admittance, and volume values in both ears between groups (p > 0.05). Bilateral ipsilateral and contralateral acoustic reflex threshold was evaluated between 0.5 kHz and 4 kHz, and no statistically significant difference was obtained between the groups. Also, no significant differences were observed between the two groups in 1.0, 1.4, 2.0, 2.8, and 4.0 kHz TEOAE values in both ears (p > 0.05) (Table 3).

Table 3. Comparison of transient evoked oto-acoustic emissions (TEOAE) values in groups

t = independent sample t-test

The ABR test compared the groups’ absolute latencies and amplitudes of I, III, and V and interpeak latencies and amplitudes of I–III, III–V, and I–V for both ears. No significant difference was found in all measurements (p >0.05) (Table 4). In the middle latency response test, absolute latencies of the components Pa, Na, Pb, and interpeak latencies of Na-Pa for both ears were compared between the groups, and no significant difference was found in all measurements (p > 0.05).

Table 4. Comparison of ABR wave latencies and amplitudes in groups

t = independent sample t-test; U = Mann–Whitney U test

Comparison of extended high-frequency thresholds of treatment and non-treatment groups

Sixteen (53 per cent) individuals in the study group received favipiravir (treatment group), and 14 (47 per cent) did not receive any drug treatment (non-treatment group). Although bilateral 10, 12.5, and 14 kHz extended high-frequency thresholds were higher in the treatment group, no statistically significant difference was observed between the treatment and non-treatment groups (p >0.05). There was also no age difference between the groups (treatment group mean = 35.38 ± 11.40; non-treatment group mean = 33.64 ± 12.10; p = 0.690).

Follow-up results

Twenty-five of 30 participants were followed up after six months post-polymerase chain reaction. The eight participants who self-reported hearing or communication complaints at the first evaluation continued to have problems in the six-month follow up except for ear fullness. None of the participants experienced new-onset hearing or communication problems.

Tinnitus persisted in all participants (10 per cent) six months after the disease, but the VAS-annoyance and VAS-tinnitus loudness decreased for all participants. The mean VAS-annoyance was 1.33 ± 0.58 (minimum 1, maximum 2), and VAS-tinnitus loudness was two for all participants. A statistically significant difference was obtained between the initial and follow-up measurements of only the right ear 500 Hz air-conduction hearing threshold (p = 0.020). The mean threshold value was 2.40 ± 5.02 in the first measurement and 4.40 ± 5.06 in the follow-up measurement. In the follow-up study, intra-group comparisons of other audiological evaluations did not show a significant difference (p > 0.05).

Discussion

This study showed a significant difference only in 10 kHz and 12 kHz extended high-frequency thresholds, bilaterally, between Covid-19 patients and healthy individuals. No other significant peripheral and central auditory effects were found. In addition, no clinically significant changes in hearing were detected during the six-month follow-up study.

Our study found no evidence to support the peripheral effect of Covid-19 with 250–8000 Hz PTA and transient evoked oto-acoustic emissions (TEOAE). Some studies have shown an increase in high-frequency pure tone thresholds (2/4–8 kHz) and a decrease in TEOAE amplitudes.Reference de Sousa, Costa, Xará, Pinto, Almeida and Sousa7,Reference Mustafa9Reference Rahimi, Rouhbakhsh and Manshadi11 In contrast, others had unchanged PTA results with a significant decrease in TEOAE amplitudes.Reference Daikhes, Karneeva, Machalov, Kuznetcov, Sapozhnikov and Balakina6 These studies support that there is cochlear damage due to Covid-19. However, other studies either found no significant difference in hearing thresholds or TEOAEReference Dror, Kassis-Karayanni, Oved, Daoud, Eisenbach and Mizrachi14,Reference Durgut, Karataş, Çelik, Dikici, Solmaz and Gencay15,Reference Kokten, Celik, Mutlu, Pektas, Icten and Kalcıoglu17Reference Yıldız19 or both, or stated that the difference was not statistically significant.Reference Gallus, Melis, Rızzo, Piras, De Luca and Tramaloni16

Bilateral 10 kHz and 12.5 kHz extended high-frequency threshold values of the patient group after Covid-19 were higher than the control group. The patient group's bilateral 10 kHz and 12.5 kHz extended high-frequency thresholds exceeded 20 dB HL. Although normal values of extended high-frequency thresholds are not standardised, many studies show that the average threshold values for these frequencies in adults with normal hearing do not exceed 20 dB HL.Reference Oppitz, Silva, Garcia and Silveira21 The mean extended high-frequency thresholds of the patient group is higher than the control group and deviates from this norm value by approximately 5–10 dB HL.

This finding supports a peripheral effect at the most basal region of the cochlea. In the literature, some studies support a difference in extended high-frequency thresholds between the patient and control groups.Reference Gedik, Hüsam, Başöz, Tas and Aksoy8,Reference Öztürk, Kavruk and Aykul10,Reference Emekci, Dündar, Kirazlı, Men Kılınç, Cengiz and Karababa13 It is unknown whether inner-ear involvement is a viral effect, or an effect of Covid-19 drug treatment. It is known that the SARS-CoV-2 uses angiotensin-converting enzyme 2 (ACE2) as a key receptor for cell entry, and transmembrane serine protease 2 facilitates cell fusion.Reference Hoffmann, Kleine-Weber, Schroeder, Krüger, Herrler and Erichsen22 Uranka et al. (2020) detected ACE2 and transmembrane serine protease 2 in various cells in the organ of Corti and stria vascularis of the mouse cochlea, suggesting that the inner ear is sensitive to SARS-CoV-2.Reference Uranaka, Kashio, Ueha, Sato, Bing and Ying23 Jeong et al. (2021) demonstrated the relationship between SARS-CoV-2 and hair-cell damage in the inner ear with in vitro cell models.Reference Jeong and Choi24 Although studies do not explain why the virus mainly affects only high frequencies, they show that it may affect the peripheral hearing system.

Aging, noise exposure and ototoxic drugs also affect extended high-frequency thresholds. In the study, these variables were controlled, and only the effect of Covid-19 drug treatment on extended high-frequency thresholds was analysed. Sixteen favipiravir users who were similar in age range were compared to fourteen non-drug users. Extended high-frequency thresholds were higher in the drug group, but this difference was not statistically significant. Although it has been suggested that favipiravir may have had a potential ototoxic effect when first used to treat Covid-19,Reference Ciorba, Corazzi, Skarżyński, Skarżyńska, Bianchin and Pelucchi25 it is still unknown. Favipiravir is among the nucleoside analogues that some nucleoside antilogues of antiviral drugs are known to affect the inner ear.Reference Cianfrone, Pentangelo, Cianfrone, Mazzei, Turchetta and Orlando26 A study that examined the direct drug effect by comparing hydroxychloroquine users, non-drug users, and control groups showed that TEOAE amplitudes were lower in the drug group. However, there was no difference in the 0.25–8 kHz hearing thresholds. This finding suggests hydroxychloroquine use may cause inner ear damage that is not reflected in conventional audiological thresholds.Reference Rahimi, Rouhbakhsh and Manshadi11

In a controlled study using an extensive audiologic test battery like our study, extended high-frequency threshold results differed, although our other test results were similar. The researchers also found no difference in extended high-frequency thresholds between groups.Reference Visram, Jackson, Guest, Plack, Brij and Chaudhuri27 The possible reason may be that factors other than Covid-19 that will affect extended high-frequency thresholds become more common with advanced age and the variation in extended high-frequency thresholds increases, or the possible effect of favipiravir use by some of the participants in our study. For this reason, it is recommended that drug users, non-drug users, and control-group studies be examined in a large sample and with an extensive audiological test battery, including extended high-frequency audiometry, to examine a similar effect for favipiravir in a more controlled manner.

In our study, which included ABR for a brainstem level assessment, no significant differences were observed for ABR latencies and amplitudes between groups. In the literature, no evidence supports that Covid-19 affects the auditory system at the brainstem level in studies conducted with ABR.Reference Gedik, Hüsam, Başöz, Tas and Aksoy8,Reference Tan, Cengiz, Demir, Demirel, Çolak and Karakaş12,Reference Visram, Jackson, Guest, Plack, Brij and Chaudhuri27 One study reported that mild latency prolongation might be insignificant and may be due to peripheral hearing loss rather than possible brainstem damage.Reference Öztürk, Kavruk and Aykul10 Masking-level difference, a behavioural test that provides information at the lower brainstem level, was also added to the test battery in this study. There was no difference in masking-level difference score between the groups. As SARS-CoV-2 has been observed to be able to affect other cranial nerves (ophthalmoparesis, optic neuritis, anosmia), it was considered that SARS-CoV-2 may directly affect the vestibulocochlear nerveReference Cherchi28 and, in general, possible brainstem involvement in symptoms also has been considered.Reference Machado, DeFina, Chinchilla, Machado and Machado29

Nevertheless, as a result of ABR and masking-level difference test results, there is no auditory impairment at the brainstem level in Covid-19 patients in our study. Auditory pathways were also examined at the midbrain level; no difference was observed between the two groups regarding MLR test results. As a result of these assessments, no findings in this study supported that Covid-19 affects the central auditory system at the brainstem and midbrain levels.

In the six-month follow-up study, a statistically significant difference was observed between the first and second measurements only in the right ear 500 Hz hearing threshold. The mean hearing threshold was 2.40 in the first measurement and 4.40 in the second measurement. Since the difference between the two measurements was less than 5 dB HL, this difference was not clinically significant. No statistically or clinically significant new auditory changes with late onset were detected. Only one study with a control group examining the long-term auditory effect was found in the literature. Our results support this finding.Reference Yıldız19 It was observed that the extended high-frequency thresholds determined in the first measurement was similar in the follow-up study, and the decrease in extended high-frequency thresholds was thought to be persistent at six months.

  • The long-term effects of coronavirus disease 2019 on hearing have not been sufficiently investigated with an extensive audiological test battery

  • In this study, only 10 kHz and 12.5 kHz extended high-frequency thresholds were affected in coronavirus disease 2019 patients compared to the control group (no results support that the peripheral auditory system is affected, except for the difference in extended high-frequency thresholds)

  • Behavioural and electrophysiological audiological test results do not provide evidence that the central auditory system is affected in individuals with COVID-19

  • In the six-month follow-up study, the effect on extended high-frequency thresholds appeared permanent, but no clinically significant new, late-onset auditory system effects were observed

  • The possible effect of coronavirus disease 2019 on extended high-frequency thresholds may have been missed because studies mostly included conventional thresholds

  • The results of this study are valuable in that they present both behavioural and electrophysiological audiological test results in a relatively large sample

One of the limitations of this study is that a polymerase chain reaction test was not requested from the individuals in the control group as it was thought that polymerase chain reaction-negative results in the control group would not eliminate the limitation. Meta-analysis studies have reported that the polymerase chain reaction test can give false negative results and that a negative result does not completely exclude SARS-CoV-2 infection.Reference Pecoraro, Negro, Pirotti and Trenti30,Reference Pu, Liu, Ren, Shi, Ba and Huo31 As in other studies with the control group features, this was considered one of the limitations of the study. In addition, some virus-specific features (such as variants) may affect auditory outcomes. In the literature, there are differences in ENT symptoms according to variants.Reference Hagemann, Onorato, Seifen, Becker, Huppertz and Olze32 While hearing loss is a rare symptom in patients with the Alpha variant of Covid-19, it has been reported that hearing loss is more common as a symptom in the Delta variant.Reference Umashankar, Prakash and Prabhu33 Since the study also had a follow-up component, data were collected over a wide period. Therefore, it is not possible to draw inferences about auditory outcomes specific to the dominant variant.

Conclusion

In the Covid-19 group aged 20-–55 with mild symptoms, only 10 kHz and 12.5 kHz extended high-frequency thresholds were higher than the healthy group. No auditory effects were found at the brainstem and midbrain levels. The effect on extended high-frequency thresholds appeared permanent in the six-month follow-up study, but no clinically significant new late-onset auditory system effects were observed. The results of this study are valuable in that they present both behavioural and electrophysiological audiological test results in a relatively large sample.

Acknowledgements

We would like to thank Eda Çakmak (PhD) for her assistance in the statistical analysis, and Kübra Özmen (PhD) for critical review.

Funding

The authors declared that this study received no financial support.

Competing interests

The author(s) declare none.

Footnotes

Merve Deniz-Sakarya takes responsibility for the integrity of the content of the paper

References

Collantes, MEV, Espiritu, AI, Sy, MCC, Anlacan, VMM, Jamora, RDG. Neurological manifestations in COVID-19 infection: a systematic review and meta-analysis. Can J Neurol Sci 2021;48:6676.10.1017/cjn.2020.146CrossRefGoogle ScholarPubMed
Deva, FAL, Gupta, A, Manhas, M, Kalsotra, P. Neuro-otological symptoms: an atypical aspect of covıd-19 disease. Indian J Otolaryngol Head Neck Surg 2022;74(suppl 2):3273–82.10.1007/s12070-022-03088-zCrossRefGoogle ScholarPubMed
Eravci, FC, Alafifi, M, Dündar, MA, Korkmaz, C, Demirbaş, S, Vatansev, H et al. Neurotological manifestations of patients with Covid-19. Kulak Burun Bogaz Ihtis Derg 2021;29:168–75.Google Scholar
Umashankar, A, Prakash, P, Prabhu, P. Sudden sensorineural hearing loss post coronavirus disease: a systematic review of case reports. Indian J Otolaryngol Head Neck Surg 2022;74(suppl 2):3028–35.10.1007/s12070-021-02756-wCrossRefGoogle ScholarPubMed
Wagatsuma, Y, Daimaru, K, Deng, S, Chen, JY. Hearing loss and the COVID-19 pandemic. BMC Res Notes 2022;15:228.10.1186/s13104-022-06120-1CrossRefGoogle ScholarPubMed
Daikhes, NA, Karneeva, OV, Machalov, AS, Kuznetcov, AO, Sapozhnikov, YM, Balakina, AV et al. Audiological profile of patients with SARS-CoV-2-PCR-positive cases [in Russian]. Vestn Otorinolaringol 2020;85:611.10.17116/otorino2020850516CrossRefGoogle Scholar
de Sousa, FA, Costa, RP, Xará, S, Pinto, AN, Almeida, E, Sousa, C. SARS-CoV-2 and hearing: an audiometric analysis of COVID-19 hospitalized patients. J Otol 2021;16:158–64.10.1016/j.joto.2021.01.005CrossRefGoogle Scholar
Gedik, Ö, Hüsam, H, Başöz, M, Tas, N, Aksoy, F. The effect of coronavirus disease 2019 on the hearing system. J Laryngol Otol 2021;135:810–14.10.1017/S0022215121001961CrossRefGoogle ScholarPubMed
Mustafa, MWM. Audiological profile of asymptomatic Covid-19 PCR-positive cases. Am J Otolaryngol 2020;41:102483.10.1016/j.amjoto.2020.102483CrossRefGoogle ScholarPubMed
Öztürk, B, Kavruk, H, Aykul, A. Audiological findings in individuals diagnosed with Covid-19. Am J Otolaryngol 2022;43:103428.10.1016/j.amjoto.2022.103428CrossRefGoogle ScholarPubMed
Rahimi, V, Rouhbakhsh, N, Manshadi, SAD. Slight high-frequency hearing loss, the effect of Covıd-19 or hydroxychloroquine usage? Otol Neurotol 2022;43:944–50.10.1097/MAO.0000000000003649CrossRefGoogle ScholarPubMed
Tan, M, Cengiz, DU, Demir, İ, Demirel, S, Çolak, SC, Karakaş, O et al. Effects of Covid-19 on the audio-vestibular system. Am J Otolaryngol 2021;43:103173.10.1016/j.amjoto.2021.103173CrossRefGoogle ScholarPubMed
Emekci, T, Dündar, MA, Kirazlı, G, Men Kılınç, F, Cengiz, DU, Karababa, E et al. Evaluation of the efferent auditory system in Covid-19 adult patients. Acta Otolaryngol 2022;142:509–14.10.1080/00016489.2022.2093967CrossRefGoogle ScholarPubMed
Dror, AA, Kassis-Karayanni, N, Oved, A, Daoud, A, Eisenbach, N, Mizrachi, M et al. Auditory performance in recovered SARS-CoV-2 patients. Otol Neurotol 2021;42:666–70.10.1097/MAO.0000000000003037CrossRefGoogle ScholarPubMed
Durgut, O, Karataş, M, Çelik, Ç, Dikici, O, Solmaz, F, Gencay, S. The effects of SARS-CoV-2 on hearing thresholds in Covıd-19 patients with non-hospitalized mild disease. Am J Otolaryngol 2022;43:103320.10.1016/j.amjoto.2021.103320CrossRefGoogle ScholarPubMed
Gallus, R, Melis, A, Rızzo, D, Piras, A, De Luca, LM, Tramaloni, P et al. Audiovestibular symptoms and sequelae in Covid-19 patients. J Vestib Res 2021;31:381–7.10.3233/VES-201505CrossRefGoogle ScholarPubMed
Kokten, N, Celik, S, Mutlu, A, Pektas, E, Icten, S, Kalcıoglu, MT. Does Covid-19 have an impact on hearing? Acta Otolaryngol 2022;142:4851.10.1080/00016489.2021.2020897CrossRefGoogle ScholarPubMed
Kökoğlu, K, Tektaş, N, Baktir-Okcesiz, FE, Şahin, M. Mild and moderate Covid-19 disease does not affect hearing function permanently: a cross-sectional study involving young and middle-aged healthcare givers. Eur Arch Otorhinolaryngol 2021;278:3299–305.10.1007/s00405-021-06883-6CrossRefGoogle ScholarPubMed
Yıldız, E. Comparison of pure tone audiometry thresholds and transient evoked otoacoustic emissions (TEOAE) of patients with and without Covid-19 pneumonia. Am J Otolaryngol 2022;43:103377.10.1016/j.amjoto.2022.103377CrossRefGoogle ScholarPubMed
Zhou, Z, Kang, H, Li, S, Zhao, X. Understanding the neurotropic characteristics of SARS-CoV-2: from neurological manifestations of Covıd-19 to potential neurotropic mechanisms. J Neurol 2020;267:2179–84.10.1007/s00415-020-09929-7CrossRefGoogle ScholarPubMed
Oppitz, SJ, Silva, LCLD, Garcia, MV, Silveira, AFD. High-frequency auditory thresholds in normal hearing adults. Codas 2018;30: e20170165.Google ScholarPubMed
Hoffmann, M, Kleine-Weber, H, Schroeder, S, Krüger, N, Herrler, T, Erichsen, S et al. SARS-CoV-2 cell entry depends on ACE2 and TMPRSS2 and is blocked by a clinically proven protease inhibitor. Cell 2020;181:271–80.10.1016/j.cell.2020.02.052CrossRefGoogle ScholarPubMed
Uranaka, T, Kashio, A, Ueha, R, Sato, T, Bing, H, Ying, G et al. Expression of ACE2, TMPRSS2, and Furin in mouse ear tissue, and the implications for SARS-CoV-2 infection. Laryngoscope 2021;131:2013–17.10.1002/lary.29324CrossRefGoogle ScholarPubMed
Jeong, J, Choi, HS. Sudden sensorineural hearing loss after Covid-19 vaccination. Int J Infect Dis 2021;113:341–3.10.1016/j.ijid.2021.10.025CrossRefGoogle ScholarPubMed
Ciorba, A, Corazzi, V, Skarżyński, PH, Skarżyńska, MB, Bianchin, C, Pelucchi, S et al. Don't forget ototoxicity during the SARS-CoV-2 (Covid-19) pandemic! Int J Immunopathol Pharmacol 2020;34:2058738420941754.10.1177/2058738420941754CrossRefGoogle ScholarPubMed
Cianfrone, G, Pentangelo, D, Cianfrone, F, Mazzei, F, Turchetta, R, Orlando, MP et al. Pharmacological drugs inducing ototoxicity, vestibular symptoms and tinnitus: a reasoned and updated guide. Eur Rev Med Pharmacol Sci 2011;15:601–36.Google ScholarPubMed
Visram, AS, Jackson, IR, Guest, H, Plack, CJ, Brij, S, Chaudhuri, N et al. Pre-registered controlled comparison of auditory function reveals no difference between hospitalized adults with and without COVID-19. Int J Audiol 2023;62:113.Google Scholar
Cherchi, M. Otovestibular symptoms of Covid-19 and its vaccines/treatments. Encyclopedia (Basel) 2022;2:1200–9.10.3390/encyclopedia2030080CrossRefGoogle Scholar
Machado, C, DeFina, PA, Chinchilla, M, Machado, Y, Machado, Y. Brainstem dysfunction in SARS-CoV-2 infection can be a potential cause of respiratory distress. Neurol India 2020;68:989–93.10.4103/0028-3886.299165CrossRefGoogle ScholarPubMed
Pecoraro, V, Negro, A, Pirotti, T, Trenti, T. Estimate false-negative RT-PCR rates for SARS-CoV-2. A systematic review and meta-analysis. Eur J Clin Invest 2022;52:e13706.10.1111/eci.13706CrossRefGoogle ScholarPubMed
Pu, R, Liu, S, Ren, X, Shi, D, Ba, Y, Huo, Y et al. The screening value of RT-LAMP and RT-PCR in the diagnosis of Covıd-19: systematic review and meta-analysis. J Virol Methods 2022;300:114392.10.1016/j.jviromet.2021.114392CrossRefGoogle ScholarPubMed
Hagemann, J, Onorato, G, Seifen, C, Becker, S, Huppertz, T, Olze, H et al. Presentation of airway and general symptoms in Covid-19 caused by dominant SARS-CoV-2 variants: a follow-up on ARIA consensus. Allergy 2022;77:3440–4.10.1111/all.15416CrossRefGoogle Scholar
Umashankar, A, Prakash, P, Prabhu, P. Delta variant of Covid-19 and hearing loss. Indian J Otolaryngol Head Neck Surg 2023;75:2634–6.10.1007/s12070-023-03724-2CrossRefGoogle ScholarPubMed
Figure 0

Table 1. Characteristics of participants

Figure 1

Table 2. Comparison of pure-tone and extended high-frequency audiometry test results in groups

Figure 2

Table 3. Comparison of transient evoked oto-acoustic emissions (TEOAE) values in groups

Figure 3

Table 4. Comparison of ABR wave latencies and amplitudes in groups