Hostname: page-component-cd9895bd7-dk4vv Total loading time: 0 Render date: 2024-12-28T14:45:10.788Z Has data issue: false hasContentIssue false

Thyroid surgery and recurrent laryngeal nerve monitoring

Published online by Cambridge University Press:  24 March 2006

S Bailleux
Affiliation:
Department of ENT and Maxillofacial Surgery, Pasteur Hospital, Nice, France
A Bozec
Affiliation:
Department of ENT and Maxillofacial Surgery, Pasteur Hospital, Nice, France
L Castillo
Affiliation:
Department of ENT and Maxillofacial Surgery, Pasteur Hospital, Nice, France
J Santini
Affiliation:
Department of ENT and Maxillofacial Surgery, Pasteur Hospital, Nice, France

Abstract

Recurrent laryngeal nerve paralysis is a much-dreaded complication of thyroid surgery.

Objective: To study the feasibility and the reliability of a recurrent laryngeal nerve monitoring technique.

Materials and methods: This was a prospective study including 36 patients proposed for thyroid surgery with recurrent laryngeal nerve monitoring. They underwent post-operative fibre-optic laryngeal examination and speech therapist consultation.

Results: Our technique of nerve monitoring showed a 98 per cent sensitivity and 86 per cent specificity.

Conclusions: Recurrent laryngeal nerve monitoring is a feasible and reliable technique. It can be used to avoid bilateral nerve injury and to increase the surgeon's confidence but not to replace a systematic nerve identification and a careful dissection.

Type
Main Articles
Copyright
2006 JLO (1984) Limited

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)