No CrossRef data available.
Published online by Cambridge University Press: 31 January 2011
Fourier transform infrared (FTIR) spectroscopy analysis of SCS-6 silicon carbide fibers was performed to detect the presence of oxygen in the form of SiO2. The results showed infrared peaks corresponding to SiC fundamental lattice absorption as well as reflection. No absorption peak due to SiO2 was observed. These results are in agreement with previously reported data indicating low levels of oxygen in this fiber.