Improvement of dose homogeneity with irregular surface compensator in whole brain radiotherapy

Published online by Cambridge University Press:  02 May 2016

H. Fujita*
Affiliation:
Department of Radiation Oncology, Osaka Saiseikai Nakatsu Hospital, Kita-ku, Osaka, Japan
N. Kuwahata
Affiliation:
Department of Radiation Oncology, Osaka Saiseikai Nakatsu Hospital, Kita-ku, Osaka, Japan
H. Hattori
Affiliation:
Department of Radiation Oncology, Osaka Saiseikai Nakatsu Hospital, Kita-ku, Osaka, Japan
H. Kinoshita
Affiliation:
Department of Radiation Oncology, Osaka Saiseikai Nakatsu Hospital, Kita-ku, Osaka, Japan
H. Fukuda
Affiliation:
Department of Radiation Oncology, Osaka Saiseikai Nakatsu Hospital, Kita-ku, Osaka, Japan
*
Correspondence to: Hideki Fujita, Department of Radiation Oncology, Osaka Saiseikai Nakatsu Hospital, 2-10-39 Shibata, Kita-ku, Osaka 580-0012, Japan. Tel: 81(6)6372-0333. Fax: 81(6)6105-1360. E-mail: hima71f@zeus.eonet.ne.jp

Abstract

Purpose

The aim of this study was to evaluate the dosimetric aspects of whole brain radiotherapy (WBRT) using an irregular surface compensator (ISC) in contrast to conventional radiotherapy techniques.

Methods

Treatment plans were devised for 20 patients. The Eclipse treatment planning system (Varian Medical Systems) was used for dose calculation. For the ISC, a fluence editor application was used to extend the range of optimal fluence. The treatment plan with the ISC was compared with the conventional technique in terms of doses in the planning target volume (PTV), dose homogeneity index (DHI), three-dimensional (3D) maximum dose, eye and lens doses and monitor unit (MU) counts required for treatment.

Results

Compared with conventional WBRT, the ISC significantly reduced the DHI, 3D maximum dose and volumes receiving 105% of the prescription dose, in addition to reducing both eye and lens doses (p<0·05 for all comparisons). In contrast, MU counts were higher for the ISC technique than for conventional WBRT (828 versus 328, p<0·01).

Conclusion

The ISC technique for WBRT considerably improved the dose homogeneity in the PTV. As patients who receive WBRT have improved survival, the long-term side effects of radiotherapy are highly important.

Type
Original Articles
Copyright
© Cambridge University Press 2016 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Wan, J-F, Zhang, S-J, Wang, L, Zhao, K-L. Implications for preserving neural stem cells in whole brain radiotherapy and prophylactic cranial irradiation: a review of 2270 metastases in 488 patients. J Radiat Res 2013; 54: 285291.Google Scholar
2. Slotman, B, Faivre-Finn, C, Kramer, G et al. Prophylactic cranial irradiation in extensive small-cell lung cancer. N Engl J Med 2007; 357: 664672.Google Scholar
3. Douglas, J. ICRU Report No. 50-Prescribing, recording and reporting photon beam therapy. Med Phys 1994; 21: 833.Google Scholar
4. Lerch, I A, Newall, J. Adjustable compensators for whole-brain irradiation. Radiology 1979; 130: 529532.Google Scholar
5. Keall, P, Arief, I, Shamas, S, Weiss, E, Castle, S. The development and investigation of a prototype three-dimensional compensator for whole brainradiation therapy. Phys Med Biol 2008; 53: 22672276.Google Scholar
6. Goyal, S, Yue, N J, Millevoi, R, Kagan, E, Haffty, B, Narra, V. Improvement in dose homogeneity with electronic tissue compensation over IMRT and conventional RT in whole brain radiotherapy. Radiother Oncol 2008; 88: 196201.Google Scholar
7. Gondi, V, Tolakanahalli, R, Mehta, M P et al. Hippocampal-sparing whole-brain radiotherapy: a ‘how-to’ technique using helical tomotherapy and linear accelerator-based intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys 2010; 78: 12441252.Google Scholar
8. Marsh, J C, Gielda, B T, Herskovic, A M, Wendt, J A, Turian, J V. Sparing of the hippocampus and limbic circuit during whole brain radiation therapy: a dosimetric study using helical tomotherapy. J Med Imaging Radiat Oncol 2010; 54: 375382.Google Scholar
9. van Kesteren, Z, Belderbos, J, van Herk, M et al. A practical technique to avoid the hippocampus in prophylactic cranial irradiation for lung cancer. Radiother Oncol 2012; 102: 225227.Google Scholar
10. Rong, Y, Evans, J, Xu-Welliver, M et al. Dosimetric evaluation of intensity-modulated radiotherapy, volumetric modulated arc therapy, and helical tomotherapy for hippocampal-avoidance whole brain radiotherapy. PLoS One 2015; 10: e0126222.Google Scholar
11. Kao, J, Darakchiev, B, Conboy, L et al. Tumor directed, scalp sparing intensity modulated whole brain radiotherapy for brain metastases. Technol Cancer Res Treat 2015; 14: 547555.Google Scholar
12. Hideki, F, Nao, K, Hiroyuki, H, Hiroshi, K, Haruyuki, F. Improvement of dose distribution with irregular surface compensator in whole breast radiotherapy. J Med Phys 2013; 38: 115119.Google Scholar
13. Tillikainen, L, Helminen, H, Torsti, T et al. A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media. Phys Med Biol 2008; 53: 38213839.Google Scholar