Hostname: page-component-745bb68f8f-d8cs5 Total loading time: 0 Render date: 2025-01-10T12:24:09.678Z Has data issue: false hasContentIssue false

Analysing breast dose in female mediastinal lymphoma patients who received radiotherapy: a retrospective audit

Published online by Cambridge University Press:  03 January 2025

Andrew Massey
Affiliation:
The Clatterbridge Cancer Centre NHS Foundation Trust, Liverpool, UK
Louise Turtle
Affiliation:
The Clatterbridge Cancer Centre NHS Foundation Trust, Liverpool, UK
Nathan Wilson*
Affiliation:
The Clatterbridge Cancer Centre NHS Foundation Trust, Liverpool, UK University of Liverpool, School of Allied Health Professions and Nursing, Liverpool, UK
Bethan Stewart-Thomson
Affiliation:
The Clatterbridge Cancer Centre NHS Foundation Trust, Liverpool, UK
Peter Robson
Affiliation:
The Clatterbridge Cancer Centre NHS Foundation Trust, Liverpool, UK
*
Corresponding author: Nathan Wilson; Email: Nathan.Wilson@liverpool.ac.uk
Rights & Permissions [Opens in a new window]

Abstract

Introduction:

Second primary breast cancers are among the most common risks to female patients who have received radiotherapy for mediastinal lymphoma.

This study aims to audit breast dose in women who received mediastinal radiotherapy for lymphoma and compare the combined dose parameter values measured to those in the literature.

Methods:

Twenty-three patient datasets from 2017 to 2021 were obtained. Inclusion criteria, such as female gender and 30Gy prescription dose, were applied. Target volumes were delineated using involved site radiotherapy and planned on Eclipse (Varian, Palo Alto, CA) using either fixed field or VMAT. Breast contours were retrospectively outlined according to RTOG/EORTC guidance and descriptive statistics were used to compare findings to those from the literature.

Results:

Differences were found in V4gy, V5Gy and mean dose compared to the literature with mean dose being 2Gy in the literature and 4Gy in this audit.

Conclusions:

Breast dose parameter values between patients in this study vary due to multiple factors. These include the treatment delivery method used and the position of the treatment field in relation to the location of breast tissue. Mean dose and V4% and V5% to breast tissue found in this study differ from that found in the literature. This study highlights the importance of accurate contouring and optimising breast tissue when possible.

Type
Original Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2025. Published by Cambridge University Press

Introduction

It is well documented that female patients with mediastinal lymphoma who are treated with radiotherapy have an increased risk of developing a second primary breast cancer 1Reference Conway, Connors, Tyldesley, Savage and Campbell10 . The risk of developing a second primary breast cancer from lymphoma radiotherapy depends upon the amount of dose received, with respect to the volume of tissue exposed Reference Verhappen, Poortmans, Raaijmakers and Raemaekers2,Reference Specht, Yalahom, Illidge, Berthelsen and Constine9,Reference Conway, Connors, Tyldesley, Savage and Campbell10 . This means that variations in target delineation and treatment delivery techniques affect dose received by breast tissue and other organs at risk (OARs) Reference Verhappen, Poortmans, Raaijmakers and Raemaekers2Reference Conway, Connors, Tyldesley, Savage and Campbell10 .

Acknowledgement of the late effect risk of developing second primary cancers, alongside other late toxicities, led to a drive to further reduce the size of the treatment volumes for patients receiving radiotherapy for mediastinal lymphoma. Initially, this meant going from an extended field radiotherapy (EFRT) technique covering most of the thorax with shielding for the lungs to involved field radiotherapy (IFRT) technique, which primarily involved just the localised region of original disease-involved nodes pre chemotherapy Reference Witkowska, Majchrza and Smolewski3,Reference Hoskin, Diez, Williams, Lucraft and Bayne4 (Figure 1). In a trial originally investigating the efficacy of IFRT Reference Engert, Schiller, Josting, Herrmann and Koch5 , 1064 patients with early-stage unfavourable Hodgkin lymphoma were randomised to be prescribed either 30Gy EFRT or IFRT after receiving 4 cycles of chemotherapy. No significant differences were found in overall survival, freedom from treatment failure and progression-free survival at the 10 years follow up. Moreover, treatment with IFRT had a significantly lower rate of acute toxicity, with a non-statistically significant lower rate of secondary malignancies in patients compared to EFRT Reference Engert, Schiller, Josting, Herrmann and Koch5,Reference Diehl6 . This led to IFRT becoming the gold standard in radiotherapy for treating nodal lymphomas in the UK from 2003 onwards Reference Hoskin, Diez, Williams, Lucraft and Bayne4 .

Figure 1. Taken from Witkowska et al, (2015) Reference Witkowska, Majchrza and Smolewski3 shows the differences in radiotherapy target delineation techniques. (a) shows involved lymph nodes, (b) shows an extended field technique, (c) shows involved field radiotherapy and (d) shows involved nodal radiotherapy.

When computerised positron emission tomography (PET)-CT was implemented to aid diagnosis and staging, the full extent of disease-involved nodes could be visualised. It is known that most reoccurrences of lymphoma begin in the initially involved nodes Reference Girinsky, van der Maazen, Specht, Aleman and Poortmans7,Reference Specht, Yalahom, Illidge, Berthelsen and Constine9,Reference Conway, Connors, Tyldesley, Savage and Campbell10 . Therefore, it was hypothesised in several studies that treating only the initially involved nodes highlighted from the PET-CT scan could provide an equally effective treatment for lymphoma to IFRT in terms of disease-free survival, but with a further reduced dose to OAR Reference Girinsky, van der Maazen, Specht, Aleman and Poortmans7,Reference Specht, Yalahom, Illidge, Berthelsen and Constine9,Reference Conway, Connors, Tyldesley, Savage and Campbell10 . This led to the development of the treatment delineation technique involving node radiotherapy (INRT) where only the involved nodes, highlighted from the PET-CT scan, are treated (Figure 1) Reference Witkowska, Majchrza and Smolewski3,Reference Girinsky, van der Maazen, Specht, Aleman and Poortmans7,Reference Specht, Yalahom, Illidge, Berthelsen and Constine9,Reference Conway, Connors, Tyldesley, Savage and Campbell10 . For INRT, it is required that the PET-CT scan take place in the original radiotherapy treatment position, which is ideal as it enables reproducibility of position on treatment Reference Specht, Yalahom, Illidge, Berthelsen and Constine9 . However, this is not always possible due to differences in equipment size and suitability and appointments and equipment being spread out across differing treatment centres, Reference Portlock8 which led to the development of involved site radiotherapy (ISRT), which is a less rigid version of INRT that does not require the PET-CT to take place in the radiotherapy treatment position, meaning the Gross Tumour Volume (GTV) information may not be fully optimal Reference Portlock8 . To this end, this can also mean that a larger Clinical Target Voume (CTV) is contoured compared to INRT for ISRT, based on clinical judgement and the imaging information available Reference Specht, Yalahom, Illidge, Berthelsen and Constine9 . Both INRT and ISRT are currently recommended by the International Lymphoma Radiation Oncology Group for treatment of lymphoma patients Reference Specht, Yalahom, Illidge, Berthelsen and Constine9,Reference Conway, Connors, Tyldesley, Savage and Campbell10 .

Currently, the Author’s Centre does not routinely record breast doses for female patients receiving radiotherapy for supradiaphragmatic lymphoma. Therefore, risks of a second primary breast cancer locally to these patients are unquantified. Although the aforementioned changes to target delineation and treatment delivery methods have been introduced to reduce dose to breast tissue, there is still an increased risk of second primary breast cancer at lower doses, even reportedly as low as 0·24Gy Reference Wirth, Kron, Wittwer, Sullivan, Sorrell and Cramb11 . Moreover, second primary breast cancers from lymphoma radiotherapy are more likely to be triple-negative and or bilateral than de novo primary breast cancers Reference Conway, Connors, Tyldesley, Savage and Campbell10,Reference Horst, Hancock, Ognibene, Chen and Advani12 . This means these women are more likely to have a worse prognosis at diagnosis Reference Conway, Connors, Tyldesley, Savage and Campbell10,Reference Horst, Hancock, Ognibene, Chen and Advani12,Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13 . Therefore we decided to audit breast dose in previously treated patients to allow for potential future investigations of risk and follow up care interventions to take place.

The aim of this study was to audit breast dose in women who have received external beam radiotherapy for nodal lymphoma involving the mediastinum at a single UK Cancer Centre and compare those to the literature.

The Objectives of this study were to:

  • Extract dose parameter values from suitable plans for comparison between patients.

  • Compare the combined dose parameter values found in this study to those in similar studies.

Methodology

Patient selection

A retrospective audit was conducted for female patients up to the age of 36 who were previously treated with external beam radiotherapy (EBRT) for nodal lymphoma involving the mediastinum. Patients were sourced from the trust’s Aria (Varian Medical Systems, Palo Alto, CA) patient database by utilising a database search report for patients who had lymphoma with mediastinal involvement between 2017 and 2021. Patients with lymphoma in the mediastinum were the focus of this study, due to the proximity of the mediastinum to the breast. Furthermore, examining patients with mediastinal lymphoma allows for comparison between studies found in the literature review as most studies examining breast dose in lymphoma patients focussed on patients with mediastinal involvement Reference Conway, Connors, Tyldesley, Savage and Campbell10,Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13 . Patients up to the age of 36 were selected initially due to the known increased risk of breast cancer 14 . This left only 7 patients who would have been eligible for inclusion into the audit out of the 23 patients treated with EBRT for mediastinal lymphoma. To expand the number of suitable patients for a larger sample size, the inclusion criteria were amended to instead include female-only patients of any age, due to women of all ages having breast tissue, along with a 30Gy prescription, and confirmed mediastinal involvement in their patient notes. Exclusion criteria included male patients, with incomplete breast tissue on their scan data due to a reduced amount of or incomplete amount of breast tissue on the CT dataset. Patients with no mediastinal involvement documented in their notes were excluded to enable comparison with other studies and due to a likelihood of limited breast tissue receiving dose for these patients and a prescription dose which was not 30Gy was also excluded to enable uniform comparison between patients without prescription dose influencing breast dose. All patients underwent a pre-radiotherapy CT scan of 3 mm slice thickness. Ethics approval was obtained from the author’s centre prior to data collection.

Plan information

Treatment plans used in this study were originally used for patient treatment and no changes were made to any of the original planning decisions. All treatments were planned in Eclipse v15·6 (Varian Medical Systems, Palo Alto, CA) using the Acuros dose algorithm. Treatment planning staff at the trust provided training on using Eclipse for the author to extract data from plan dose-volume histograms from the treatment plan and in utilising the contouring tools to outline breast tissue. Plans selected were either Intensity Modulated Radiotherapy (IMRT) fixed field or VMAT plans.

The dose parameters used for this study encompassed those at both lower and higher doses namely V4Gy, V5Gy, V20Gy, D1%, and mean dose Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15Reference Scorsetti, Cozzi, Navarria, Fogliata and Rossi19 . These parameters were utilised in the literature and allowed for effective comparison to other studies Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15Reference Scorsetti, Cozzi, Navarria, Fogliata and Rossi19 . Descriptive statistics were utilised to enable comparison between patients. All plans utilised the target delineation method ISRT Reference Witkowska, Majchrza and Smolewski3,Reference Portlock8Reference Conway, Connors, Tyldesley, Savage and Campbell10 . Acceptable dose limits to the PTV were between 95% and 107% in accordance with International Commission on Radiation Units and Measurements (ICRU) guidelines 20 . All plans selected for contouring were anonymised and copied to enable contouring of breast tissue. To allow for accurate anatomical boundaries to be adhered to in terms of contouring and enable repeatability in future studies, breast contouring in this study was conducted using a combination of RTOG and ESTRO breast contouring guidelines 21,Reference Offersen, Boersma, Kirkove, Hol and Aznar22 .

Results were recorded as either combined or separate breasts within the literature Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15Reference Scorsetti, Cozzi, Navarria, Fogliata and Rossi19 . Therefore, to allow for comparisons between all studies within the review, breast dose results were reported as both combined and separate breasts in this audit. Patients with breast contours already outlined had new contours produced using the RTOG/ESTRO guidelines to ensure consistency in results 21,Reference Offersen, Boersma, Kirkove, Hol and Aznar22 . Combined breast contours were made by combining the left and right breast contours as a new structure.

Results

Patient information

The Aria database search post application of inclusion and exclusion criteria resulted in 23 eligible patients for selection. All plans selected were planned at 6MV. IMRT and VMAT separation data are found in Table 1. Three patients out of the 23 had breast contours already produced in their structure sets. These three patients were all 34 years of age or under at time of treatment. Two of these three patients had breast-related optimisation objectives in place to reduce dose to the breast tissue (Table 2). One patient’s plan was combined with their replan to form a single new plan.

Table 1. The number of plans for the different treatment delivery methods used

Table 2. Clinical attributes from patients >36 years of age including those who had their breast tissue contoured prior to this audit

Plan Analysis

Data for each patient regarding their individual dose parameter values can be found in Appendix 13. Means, medians, maximum and minimum values and ranges were calculated for each dose parameter for the left, right and combined breasts, using all plans. These can be found in Tables 35. Box plots of Interquartile range (IQR) data for each parameter for each breast were constructed to illustrate the distribution of the data (Figures 2 & 3).

Table 3. Descriptive statistic combined results for each dose parameter for the left breast (n = 23)

Table 4. Descriptive statistic combined results for each dose parameter for the right breast (n = 23)

Table 5. Descriptive statistic combined results for each dose parameter for the combined breasts (n = 23)

Figure 2. Comparison of range of volume in % of breast tissue irradiated to V4Gy, V5Gy and V20y for the right, left and combined breasts.

Figure 3. Comparison of range between D1% and mean dose to breast tissue for the right, left and combined breasts.

Little difference in dose is noted between left and right breasts (Tables 35), (Figure 2). A greater volume of breast tissue is receiving around V4Gy and V5Gy compared to V20Gy and a larger range in values for V4Gy and V5Gy can also be noted compared to V20Gy (Figure 2). There is also a large range for right, left and combined breasts in terms of D1% (Tables 35) (Figure 3). Mean dose to breast tissue for the overall data appears to be just around 4Gy (Tables 35) (Figure 3).

A difference in V4Gy and V5Gy can be seen between fixed-field IMRT and VMAT treatment for left, right and combined breast data (Figure 4) in terms of the range and spread of the data. There is not much difference between treatment delivery modalities for V20Gy (Figure 4). A large range can also be seen for the D1% data with some values close to the prescription dose and some close to no dose received (Figure 5). There also appears to be a difference in mean dose received between fixed-field IMRT and VMAT (Figure 5).

Figure 4. Shows a comparison between the volume in (%) of breast tissue irradiated to V4Gy, V5Gy and V20y for the right, left and combined breasts split between fixed-field IMRT (n = 3) and VMAT (n = 20) treatment.

Figure 5. Shows a comparison between D1% and mean dose to breast tissue for the right, left and combined breasts split between fixed-field IMRT (n = 3) and VMAT (n = 20) treatment.

Visual differences in the amount of breast tissue irradiated were well observed on aria between patients (Figures 68). Moreover, differences were noted between the contouring produced for this audit and that previously present on some patients (n = 3) (Figure 9)

Figure 6. Dose colourwash showing the amount of breast tissue receiving ≥4Gy in an axial view for a VMAT plan for a patient receiving external beam radiotherapy for mediastinal lymphoma. Breast tissue is contoured in lilac. PTV is outlined in bold purple.

Figure 7. Dose colourwash showing the amount of breast tissue receiving ≥4Gy in a coronal view for a VMAT plan for a patient receiving external beam radiotherapy for mediastinal lymphoma. Breast tissue is contoured in lilac. PTV is outlined in bold purple.

Figure 8. Dose colourwash showing the amount of breast tissue receiving ≥4Gy in a frontal view for a VMAT plan for a patient receiving external beam radiotherapy for mediastinal lymphoma with the left breast receiving a greater proportion of dose ≥4Gy than the right breast due to the method of plan construction. Breast tissue is contoured in lilac. PTV is outlined in bold purple.

Figure 9. Differences in contour between the original contouring of breast tissue (pink) and the new contouring produced for this audit (lavender).

Discussion

Trends in data in this audit suggest that there is little difference in breast dose received between left and right breasts (Figures 2 & 3). Previous studies reported differences in breast dose between left and right breasts in mediastinal-involved patients with a 30Gy prescription Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15,Reference Koeck, Abo-Madyan, Lohr, Stieler and Kriz23 . Koeck et al., found all parameters measured in all plans were greater for the left breast than the right Reference Koeck, Abo-Madyan, Lohr, Stieler and Kriz23 . Conversely, Voong et al., found similar values for the left and right breasts for each parameter measured Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15 . The reasons behind these trends are not mentioned in these studies. However, it is important to note that breast tissue is not the primary target of treatment delivery for as the volume of individual or combined breast tissue irradiated is dependent upon field margin locations required to treat the target volume, which in turn is dependent on disease location, extent and each centre’s target volume margining used. It is also dependant on individual and combined breast contours, sizes, and geometric positions in relation to the location of the fields (Figure 68) with these factors being variable for all treatment techniques and patients. Therefore, there is always going to be variation between patients and between studies examining left, right and combined breast dose parameter values.

Differences in volume of breast tissue irradiated and mean dose between fixed-field IMRT and VMAT were noted within this study (Figures 4 & 5). Previous studies have suggested that the delivery technique does play a role in dose to breast tissue with VMAT resulting in an increased mean dose and V4Gy of breast tissue compared to other forms of IMRT Reference Fiandra, Filippi, Catuzzo, Botticella and Ciammella24,Reference Xu, Kang, Jiang, Liu and Li25 . Furthermore, FF-IMRT was found to increase median and low doses but reduce higher doses compared to 3D-CRT Reference Koeck, Abo-Madyan, Lohr, Stieler and Kriz23 . A more recent study however, utilising ISRT, suggests there is little difference between 3D-CRT and VMAT, although this compared a parallel opposed pair at 0o and 180o which would avoid most of the breast tissue, but could lead to higher doses in other areas Reference Edvardsson, Kügele, Alkner, Enmark and Nilsson17 . The data in this study suggest mean dose and V4Gy are higher for VMAT patients (Figures 4 & 5). However, the data for fixed-field IMRT in this study is based upon just three patients and utilises a combination of IMRT and 3D-CRT patients. Moreover, in two of the three fixed-field IMRT plans, breast dose was taken into consideration by the planners of the original plan in efforts to reduce breast dose in one patient and avoid a singular breast in another due to previous XRT (Figure 8). Additionally, within this study, two patients received partial arcs and the number of arcs varied between one and three for some patients (Table 3). This could also have influenced dosimetry to breast tissue. Therefore, the comparisons displayed within this data between these factors should be taken very tentatively.

Data from previous studies that utilised ISRT to treat mediastinal lymphoma, within 0·6Gy of a 30Gy prescription dose, can be found within (Table 6) Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15Reference Scorsetti, Cozzi, Navarria, Fogliata and Rossi19 . Differences can be noted between the audit data and the literature, most notably in terms of V4% and V5% and mean dose (Table 6). It is important to mention that the literature data compiled in the above table contains data from studies utilising different treatment delivery methods, which have previously been noted to alter dose to breast tissue Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15Reference Scorsetti, Cozzi, Navarria, Fogliata and Rossi19,Reference Fiandra, Filippi, Catuzzo, Botticella and Ciammella24,Reference Xu, Kang, Jiang, Liu and Li25 .

Table 6. Shows involved site radiotherapy planned data extracted from articles extracted from the literature along with data from the results of this audit for comparison

Differences observed between the overall combined data in this study such as a higher mean dose compared to that found within the literature (Table 6) could be partially due to this audit being primarily composed of VMAT-planned patients that did not utilise breast tissue as optimisation structure during the planning process (Table 1 & 2), as done in other VMAT planned studies Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15,Reference Edvardsson, Kügele, Alkner, Enmark and Nilsson17 . This could have instigated a higher dose VMAT-induced dose bath across breast tissue in these patients compared to the other studies which either utilised either a fixed-field Anterior-Posterior-Posterio-Anterior (AP-PA) approach, preventing a widespread low-dose bath from occurring, or had objectives in place to reduce dose to breast tissue with their multi-field IMRT or VMAT plans Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15,Reference Edvardsson, Kügele, Alkner, Enmark and Nilsson17,Reference Koeck, Abo-Madyan, Lohr, Stieler and Kriz23 . Differences in contouring technique used could also impact this as most studies did not mention the method they utilised. Differences were noted in this work between patients with breast contours already produced compared to ones outlined utilising the RTOG & ESTRO guidelines (Figure 7) 20,21 .

Further work would be required to investigate the full clinical impact of the dosimetric differences noted between the data in this audit and other studies, which could be prudent for the younger patients within this group of patients. It has been suggested previously that for patients at the age of 20, 0·1Gy received to breast tissue can increase the lifetime risk of developing breast cancer by 0·4% Reference Sun, Wang, Qiu, Liang and Xie26 . Moreover, secondary breast cancers present the highest absolute excess risk of all secondary malignancies for women receiving supradiaphragmatic radiotherapy for Hodgkin’s lymphoma according to epidemiological data Reference Schaapveld, Aleman, van Eggermond, Janus and Krol27 .

It would be beneficial therefore to monitor breast dose in future for female patients receiving EBRT for mediastinal lymphoma and encompass dose to breast tissue in treatment planning algorithms. Due to the increased risk of secondary breast cancer and depending on other clinical factors patients who have received EBRT for mediastinal lymphoma could potentially be invited to begin breast screening process at an earlier age 14 . It is notable to mention that there did not appear to be clear differentiation when it came to why some patients had breast contouring and or optimisation objectives in place, as other patients with similar clinical attributes (such as age and stage) were not contoured or optimised with regard to breast dose in this audit. Position of the target volume in relation to breast tissue, however, may have played a role in some cases but not all patients without prior contours (Table 2).

Fundamentally, it is important to state that the risk of all secondary malignancies must be weighed against each other and against the risk of other conditions when considering patient treatment. As target delineation and delivery techniques change, doses received by OAR also change (Figure 1) Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Edvardsson, Kügele, Alkner, Enmark and Nilsson17,Reference Koeck, Abo-Madyan, Lohr, Stieler and Kriz23Reference Xu, Kang, Jiang, Liu and Li25 . The treatment method chosen and construction of the dose objective optimisation algorithms should be based on an individual patient case basis. This decision for each individual should therefore consider individual clinical factors such as gender, age and other comorbidities, which may influence risk of secondary malignancy, alongside position of OAR’s in the treatment area Reference Schaapveld, Aleman, van Eggermond, Janus and Krol27 .

A novel way to reduce the volume of breast tissue in field could be to utilise an angled board for immobilisation. This was not utilised in this cohort but has been used in previous studies that demonstrated reduced dose to breast tissue from treatment delivery by positioning breast tissue further inferiorly Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15 . However, utilising such a method for treatment delivery for VMAT patients may induce some potential collision-related issues due to the extension of the patient’s elbows vertically and laterally. Moreover, it has primarily been tested in conjunction with ‘butterfly technique’ IMRT, and therefore, it is difficult to determine the full extent of its sole impact from this data Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15 .

Unfortunately, there were a limited number of fixed-field IMRT patients that could be utilised to enable a more comprehensive comparison between the treatment delivery techniques utilised. Further audits in future may benefit from making a wider array of retrospective plans on a large cohort of patients to enable a more expansive comparison and enable greater testing of different fixed-field IMRT or VMAT variations to reduce dose to breast and other OAR and make results more generalisable with wider utility.

Conclusion

In conclusion, breast dose parameter values between patients in this study vary due to multiple factors. These include the treatment delivery method used and the position of the treatment field in relation to the location of breast tissue. Mean dose and V4% and V5% to breast tissue found in this study differ from that found in the literature, but this may be due to the choice of optimisation objectives at the planning stage and the contours utilised for the breast tissue. This study highlights the importance of accurate contouring and optimising breast tissue when possible. Further studies could be carried out to standardise some optimisation objectives for patients receiving radiotherapy for mediastinal lymphomas to determine to what extent breast dose could be minimised.

Competing interests

The authors declare none.

Appendix

Appendix 1 shows all the data for the left breast for all patients

Appendix 2 shows all the data for the right breast for all patients

Appendix 3 shows all the data for the combined breasts for all patients

References

National Institute for Health and Care Excellence. Non-Hodgkin’s lymphoma: diagnosis and management. Clinical guideline NG52. 2016. (Accessed: 23rd September 2018)Google Scholar
Verhappen, MH, Poortmans, PMP, Raaijmakers, E, Raemaekers, JMM. Reduction of the treated volume to involved node radiation therapy as part of a combined modality treatment for early stage aggressive non-Hodgkin’s lymphoma. Radiother Oncol 2013; 109(1): 133139.CrossRefGoogle ScholarPubMed
Witkowska, M, Majchrza, A, Smolewski, P. The role of radiotherapy in Hodgkin’s lymphoma: what has been achieved over the last 50 years? Biomed Res Int 2015; 18.CrossRefGoogle Scholar
Hoskin, PJ, Diez, P, Williams, M, Lucraft, H, Bayne, M. Recommendations for the use of radiotherapy in nodal lymphoma, Clin Oncol 2013; 25: 4958.CrossRefGoogle ScholarPubMed
Engert, A. Schiller, P, Josting, A, Herrmann, R, Koch, P, et al. Involved-field radiotherapy is equally effective and less toxic compared with extended-field radi-otherapy after four cycles of chemotherapy in patients with early-stage unfa-vourable Hodgkin’s lymphoma: results of the HD8 trial of the German Hodg-kin’s lymphoma study group. J Clin Oncol 2003; 21(19): 36013608.CrossRefGoogle Scholar
Diehl, V. Hodgkin’s Lymphoma, An Issue in Haematology/Oncology. Revised edition. Elsevier Health Sciences, 2014.Google Scholar
Girinsky, T, van der Maazen, R, Specht, L, Aleman, B, Poortmans, PMP, et al. Involved-node radiotherapy (INRT) in patients with early Hodgkin lymphoma: concepts and guidelines. Radiother Oncol 2006; 79(3): 270277.CrossRefGoogle ScholarPubMed
Portlock, CS. Involved site radiation therapy for the treatment of early-stage Hodgkin lymphoma in adolescents and young adults. Clin Oncol Adolesc Young Adult 2015; 5: 97102.CrossRefGoogle ScholarPubMed
Specht, L, Yalahom, J, Illidge, T, Berthelsen, AK, Constine, LS, et al. Modern radiation therapy for hodgkin lymphoma: field and dose guidelines from the international lymphoma radiation oncology group (ILROG). Int J Radiat Oncol Biol Phys 2013; 89(4): 854862.CrossRefGoogle ScholarPubMed
Conway, JL, Connors, JM, Tyldesley, S, Savage, KJ, Campbell, BA, et al. Secondary breast cancer risk by radiation volume in women with Hodgkin lymphoma. Int J Radiat Oncol Biol Phys 2016; 97(1): 3541.CrossRefGoogle ScholarPubMed
Wirth, A, Kron, T, Wittwer, H, Sullivan, K, Sorrell, G, Cramb, J. Phantom measurements and computed estimates of breast dose with radiotherapy for Hodgkin’s lymphoma: dose reduction with the use of a phantom. Radiat Oncol 2008; 52: 394402.Google Scholar
Horst, KC, Hancock, SL, Ognibene, G, Chen, C, Advani, RH, et al. Histologic subtypes of breast cancer following radiotherapy for Hodgkin lymphoma, Ann Oncol 2014; 25(4): 848851.CrossRefGoogle ScholarPubMed
Murray, L, Sethugavalar, B, Robertshaw, H, Bayman, E, Thomas, E, et al. Involved node, site, field and residual volume radiotherapy for lymphoma: a comparison of organ at risk dosimetry and second malignancy risks. Clin Oncol 2015; 27: 401410.CrossRefGoogle ScholarPubMed
NHS. Breast Screening after Radiotherapy Dataset (BARD). 2015. Available at: BARD - Breast screening After Radiotherapy Dataset (christie.nhs.uk) (Accessed 23rd April 2022)Google Scholar
Voong, KR, Mcspadden, K, Pinnix, CC, Shihadeh, F, Reed, V. Dosimetric advantages of a “Butterfly” technique for intensity-modulated radiation therapy for young female patients with mediastinal hodgkin lymphoma. Radiat Oncol 2014; 9: 94.CrossRefGoogle Scholar
Kriz, J, Spickermann, M, Lehrich, P, Schmidberger, H, Reinartz, G, et al. Breath-hold technique in conventional AP-PA or intensity-modulated radiotherapy for Hodgkin’s lymphoma. Strahlenther Onkol 2015; 191: 717725.CrossRefGoogle ScholarPubMed
Edvardsson, A, Kügele, M, Alkner, S, Enmark, M, Nilsson, J et al. Comparative treatment planning study for mediastinal Hodgkin’s lymphoma: impact on normal tissues using deep inspiration breath hold proton and photon therapy. Acta Oncol 2019; 58(1):95104.CrossRefGoogle Scholar
Filippi, AR, Ragona, R, Piva, C, Scafa, D, Fiandra, C et al. Optimised volumetric arc therapy versus 3D-CRT for early-stage mediastinal Hodgkin lymphoma without axillary involvement: a comparison of second cancers and heart disease risk. Int J Radiat Oncol Biol Phys 2015; 92(1): 161168.CrossRefGoogle Scholar
Scorsetti, M, Cozzi, L, Navarria, P, Fogliata, A, Rossi, A et al. Intensity modulated proton therapy compared to volumetric modulated arc therapy in the irradiation of young female patients with Hodgkin lymphoma. Assessment of risk of toxicity and secondary cancer induction. Radiat Oncol 2020; 15(1): 12.CrossRefGoogle ScholarPubMed
International Commission on Radiation Units and Measurements. Prescribing, recording and reporting photon beam therapy (report 50). 1993.Google Scholar
Radiation Therapy Oncology Group. Breast cancer atlas for radiation therapy planning. Available at: Slide 1 (onco-hdf.fr) (Accessed 23rd April 2022)Google Scholar
Offersen, BV, Boersma, LJ, Kirkove, C, Hol, S, Aznar, MC, et al. ESTRO consensus guideline on target volume delineation for elective radiation therapy of early stage breast cancer. Radiother Oncol 2015; 114: 310.CrossRefGoogle ScholarPubMed
Koeck, J, Abo-Madyan, Y, Lohr, F, Stieler, F, Kriz, J, et al. Radiotherapy for early mediastinal Hodgkin lymphoma according to the German Hodgkin Study Group (GHSG): The role of intensity-modulated radiotherapy and involved-node radiotherapy. Int J Radiat Oncol Biol Phys 2011; 83(1): 268276.CrossRefGoogle Scholar
Fiandra, C, Filippi, AR, Catuzzo, P, Botticella, A, Ciammella, P, et al. Different IMRT solutions vs 3D conformal radiotherapy in early-stage Hodgkin’s lymphoma: dosimetric comparison and clinical considerations. Radiat Oncol 2012; 7: 186.CrossRefGoogle ScholarPubMed
Xu, LM, Kang, ML, Jiang, B, Liu, QF, Li, YX. A study of the dosimetric characteristics between different fixed-field IMRT and VMAT in early-stage primary mediastinal B-cell lymphoma. Med Dosim 2018; 43: 9199.CrossRefGoogle ScholarPubMed
Sun, W., Wang, B., Qiu, B., Liang, J., Xie, W et al. Assessment of female breast dose for thoracic cone-beam CT using MOSFET dosimeters. Oncotarget 2017; 8(12): 2017920186.CrossRefGoogle ScholarPubMed
Schaapveld, M, Aleman, BMP, van Eggermond, AM, Janus, CPM, Krol, ADG et al. Second cancer risk up to 40 years after treatment for Hodgkins lymphoma. N Engl J Med 2015; 373(26): 24992511.CrossRefGoogle ScholarPubMed
Figure 0

Figure 1. Taken from Witkowska et al, (2015)3 shows the differences in radiotherapy target delineation techniques. (a) shows involved lymph nodes, (b) shows an extended field technique, (c) shows involved field radiotherapy and (d) shows involved nodal radiotherapy.

Figure 1

Table 1. The number of plans for the different treatment delivery methods used

Figure 2

Table 2. Clinical attributes from patients >36 years of age including those who had their breast tissue contoured prior to this audit

Figure 3

Table 3. Descriptive statistic combined results for each dose parameter for the left breast (n = 23)

Figure 4

Table 4. Descriptive statistic combined results for each dose parameter for the right breast (n = 23)

Figure 5

Table 5. Descriptive statistic combined results for each dose parameter for the combined breasts (n = 23)

Figure 6

Figure 2. Comparison of range of volume in % of breast tissue irradiated to V4Gy, V5Gy and V20y for the right, left and combined breasts.

Figure 7

Figure 3. Comparison of range between D1% and mean dose to breast tissue for the right, left and combined breasts.

Figure 8

Figure 4. Shows a comparison between the volume in (%) of breast tissue irradiated to V4Gy, V5Gy and V20y for the right, left and combined breasts split between fixed-field IMRT (n = 3) and VMAT (n = 20) treatment.

Figure 9

Figure 5. Shows a comparison between D1% and mean dose to breast tissue for the right, left and combined breasts split between fixed-field IMRT (n = 3) and VMAT (n = 20) treatment.

Figure 10

Figure 6. Dose colourwash showing the amount of breast tissue receiving ≥4Gy in an axial view for a VMAT plan for a patient receiving external beam radiotherapy for mediastinal lymphoma. Breast tissue is contoured in lilac. PTV is outlined in bold purple.

Figure 11

Figure 7. Dose colourwash showing the amount of breast tissue receiving ≥4Gy in a coronal view for a VMAT plan for a patient receiving external beam radiotherapy for mediastinal lymphoma. Breast tissue is contoured in lilac. PTV is outlined in bold purple.

Figure 12

Figure 8. Dose colourwash showing the amount of breast tissue receiving ≥4Gy in a frontal view for a VMAT plan for a patient receiving external beam radiotherapy for mediastinal lymphoma with the left breast receiving a greater proportion of dose ≥4Gy than the right breast due to the method of plan construction. Breast tissue is contoured in lilac. PTV is outlined in bold purple.

Figure 13

Figure 9. Differences in contour between the original contouring of breast tissue (pink) and the new contouring produced for this audit (lavender).

Figure 14

Table 6. Shows involved site radiotherapy planned data extracted from articles extracted from the literature along with data from the results of this audit for comparison