No CrossRef data available.
Article contents
A forward planned treatment planning technique for non-small-cell lung cancer stereotactic ablative body radiotherapy based on a systematic review of literature
Published online by Cambridge University Press: 26 August 2015
Abstract
A systematic literature review of six computerised databases was undertaken in order to review and summarise a forward planned lung stereotactic ablative body radiotherapy (SABR) treatment planning (TP) technique as a starting point for clinical implementation in the author’s department based on current empirical research. The data were abstracted and content analysed to synthesise the findings based upon a SIGN quality checklist tool.
A four-dimensional computed tomography scan should be performed upon which the internal target volume and organs at risk (OAR) are drawn. A set-up margin of 5 mm is applied to account for inter-fraction motion. The field arrangement consists of a combination of 7–13 coplanar and non-coplanar beams all evenly spaced. Beam modifiers are used to assist in the homogeneity of the beam, although a 20% planning target volume dose homogeneity is acceptable. The recommended fractionations by the UK SABR Consortium are 54 Gy in 3 fractions (standard), 55–60 Gy in 5 fractions (conservative) and 50–60 Gy in 8–10 fractions (very conservative). Conformity indices for both the target volume and OAR will be used to assess the planned distribution.
An overview of a clinically acceptable forward planned lung SABR TP technique based on current literature as a starting point, with a view to inverse planning with support from the UK SABR Consortium mentoring scheme.
Keywords
- Type
- Literature Review
- Information
- Copyright
- © Cambridge University Press 2015