Hostname: page-component-cd9895bd7-dk4vv Total loading time: 0 Render date: 2024-12-28T19:32:44.005Z Has data issue: false hasContentIssue false

Étude mécanique des articles de contention et de leurs effets sur la jambe humaine

Published online by Cambridge University Press:  25 June 2009

Stéphane Avril
Affiliation:
Centre Ingénierie et Santé, PECM, UMR 5146, École Nationale Supérieure des Mines, 158 cours Fauriel, 42023 Saint-Étienne Cedex 2, France
Sylvain Drapier
Affiliation:
Centre Science des Matériaux et des Structures, LTDS, UMR 5513, École Nationale Supérieure des Mines, 158 cours Fauriel, 42023 Saint-Étienne Cedex 2, France
Laura Bouten
Affiliation:
Centre Ingénierie et Santé, PECM, UMR 5146, École Nationale Supérieure des Mines, 158 cours Fauriel, 42023 Saint-Étienne Cedex 2, France Centre Science des Matériaux et des Structures, LTDS, UMR 5513, École Nationale Supérieure des Mines, 158 cours Fauriel, 42023 Saint-Étienne Cedex 2, France
Serge Couzan
Affiliation:
BVSPORT, 104 rue Bergson, 42000 Saint-Étienne, France
Get access

Abstract

Cet article est une synthèse de différentes études apportant un regard scientifique sur la contention qui consiste à exercer des pressions sur la jambe humaine au moyen de chaussettes ou de bas afin de faciliter le reflux veineux. Il paraît évident que la répartition des pressions sur la jambe affecte le débit sanguin dans les veines. Néanmoins, la répartition conduisant à un débit veineux optimal est non triviale, et diffère en fonction de l'application : traitement médical ou récupération chez les sportifs. Afin d'améliorer les connaissances à ce sujet, un modèle numérique 2D a été mis en place pour calculer les champs de contraintes dans la jambe en prenant en compte le comportement mécanique réel des articles de contention et des tissus de la jambe. Des méthodes d'identification appropriées, basées soit sur le recalage de modèle et la corrélation d'images numériques (pour les articles de contention), soit sur le recalage de modèle par mise en correspondance locale non-linéaire d'images fournies par l'IRM (pour les tissus internes de la jambe), ont été développées pour identifier ces paramètres de comportement.

Type
Research Article
Copyright
© AFM, EDP Sciences, 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Belcaro, G., Christopoulos, D., Nicholaides, A.N., Hémodynamique veineuse des membres inférieurs, Ann. Chir. Vasc. 5 (1991) 305330 CrossRef
Blanchemaison, P., Gorny, P., Louis, G., Relation entre veines et muscles du mollet chez le sportif et le sujet sédentaire : étude échographique et conséquences physiopathologiques, Phlébologie 4 (1995) 435440
P. Ducrozet, Un nouveau concept de contention-compression veineuse évalué par un essai randomisé en double aveugle : contention progressive versus contention classique dans l'insuffisance veineuse légère : l'étude BOOSTER. Thèse de médecine de Saint Étienne No. 44, 2004
Pouget, J.-F., Geedroyc, W.M.W., Prüfer, M., Nuclear magnetic resonance (NMR) study of leg venous drainage in men with and without elastic compression socks (traditional and new bvsport concept), Int. Angiol. 19 (2000) 58
Couzan, S., Prüfer, M., Ferret, J.-M., Un nouveau concept de contention-compression : apport de l'écho-Doppler couleur avec prise des pressions veineuses et de l'IRM, Phlébologie 55 (2002) 159171
S. Couzan, J.-F. Pouget, M. Prüfer, Study of the athletes venous system by Doppler scan with pressures measurement and the perfecting of a new elastic compression, concept. Int. Angiol. 19 (2000) 41
Gefen, A., Stress analysis of the standing foot following surgical plantar fascia disease, J. Biomech. 35 (2002) 629637 CrossRef
Portnoy, S., Yizhar, Z., Shabshin, N., Itzchak, Y., Kristal, A., Dotan-Marom, Y., Siev-Ner, I., Gefen, A., Internal mechanical conditions in the soft tissues of a residual limb of a trans-tibial amputee, J. Biomech. 41 (2008) 18971909 CrossRef
Lee, W.C.C., Zhang, M., Using computational simulation to aid in the prediction of socket fit: A preliminary study, Med. Ing. Phys. 29 (2007) 923929 CrossRef
Linder-Ganza, E., Shabshin, N., Itzchak, Y., Gefen, A., Assessment of mechanical conditions in sub-dermal tissues during sitting: A combined experimental-MRI and finite element approach, J. Biomech. 40 (2007) 14431454
Gefen, A., Chen, J., Elad, D., A biomechanical model of Peyronie's disease, J. Biomech. 33 (2000) 17391744 CrossRef
Y.C. Fung, Biomechanics: mechanical properties of living tissues, Springer, Berlin, 1993
Gaied, I., Drapier, S., Lun, B., Experimental assessment and analytical 2D predictions of the stocking pressures induced on a model leg by Medical Compression Stocking, J. Biomech. 39 (2006) 30173025 CrossRef
Drapier, S., Gaied, I., Identification strategy for orthotropic knitted elastomeric fabrics under large biaxial deformations, Inv. Prob. Sci. Eng. 15 (2008) 871894 CrossRef
I. Gaied, "Contribution à l'étude de la contention : approche bidimensionnelle, identification du comportement biaxial en grandes déformations des tricots élastomériques", Thèse de doctorat de l'École des Mines de Saint-Étienne, 2004
Le comité technique CEN / TC205 : Bas médicaux de compression. Prénorme Européenne, Comité Européen de normalisation CEN, 2001
Schreier, H., Sutton, M.A., Systematic errors in digital image correlation due to undermatched subset shape functions, Exp. Mech. 42 (2002) 303310 CrossRef
Bouten, L., Drapier, S., In-vivo identification of soft biological tissues using MR Imaging, Eur. J. Comp. Mech. 18 (2009) 2132
Besnard, G., Hild, F., Roux, S., “Finite Element” displacement fields analysis from digital images: application to Portevin-Le Châtelier bands, Exp. Mech. 46 (2006) 789803 CrossRef
Amunts, K., Weiss, P.H., Mohlberg, H., Pieperhoff, P., Eickhoff, S., Gurd, J.M., Mershall, J.C., Shah, N.J., Fink, G.R., Zilles, K., Analysis of neural mechanisms underlying verbal fluency in cytoarchitectonically defined stereotaxic space – the role of Brodmann areas 44 and 45, NeuroImage 22 (2004) 4256 CrossRef