The R-Phase Transformation in the Ti-Ni Shape Memory Alloy and its Application

Published online by Cambridge University Press:  10 February 2011

I. Ohkata
Affiliation:
Medical Division, PIOLAX Inc., Yokohama, 240, Japan
H. Tamura
Affiliation:
Yokohama Research Laboratories, The Furukawa Electric Co., Ltd., Yokohama, 220, Japan
Get access

Abstract

We discuss a comprehensive design approach of Ti-Ni alloy coil springs and introduce a new application of the R-phase transformation. In order to attain high cyclic performance, one must understand the two relationships between design parameters and material characteristics and between material characteristics and cyclic performance. Metallurgical parameters and coil spring dimensions play an important role as design parameters in the former relationship. High cyclic performance of an actuator is closely related to the suppression of the monoclinic martensite. Transformation temperatures and their stress dependence is of primary importance as material characteristics in the latter relationship. A thermostatic mixing valve, which is the latest application of the R-phase transformation in Japan is then discussed as a new type of a shape memory alloy actuator. The R-phase transformation is employed to achieve not only a long cycle life but a linear operation with the set temperature to continuously control the mixing ratio of hot and cold water. This is achieved by changing the total length of the two-way actuator in a linear manner with the set temperature. The linear characteristic is satisfied between 35–50°C by optimizing thermomechanical treatment and the dimensions of Ti-Ni and biasing coil springs.

Type
Research Article
Copyright
Copyright © Materials Research Society 1997

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Tamura, H., Suzuki, Y. and Todoroki, T., Proc. Int. Conf. on Martensitic Transformations, Japan Inst. Metals, p. 736 (1986).Google Scholar
2. Miyazaki, S. and Otsuka, K., Phil. Mag. A, 50, p. 393 (1984).Google Scholar
3. Suzuki, Y., J. Rob. Mech., 1, p. 240 (1989).Google Scholar
4. Tsuzuki, Y. and Horikawa, H., Furukawa Rev., 9, p. 18 (1991).Google Scholar
5. Tamura, H., Mitose, K. and Suzuki, Y., J. DE PHYS. IV, Colloque C8, supplément au J. de Phys. III, 5, C8617 (1995).Google Scholar
6. Suzuki, Y. and Horikawa, H., Mat. Res. Soc. Symp. Proc, 246, p. 389 (1992).Google Scholar
7. Tamura, H., Furukawa Rev., 6, p. 123 (1988).Google Scholar
8. Todoroki, T. and Tamura, H., J. Japan. Inst. Metals, 50, p. 538 (1986) (in Japanese).Google Scholar
9. Todoroki, T. and Tamura, H., Trans. Japan Inst. Metals, 28, p. 83 (1987).Google Scholar
10. Tamura, H. and Suzuki, Y., Furukawa Rev., 4, p. 33 (1986).Google Scholar
11. Miyazaki, S., Ohmi, Y., Otsuka, K. and Suzuki, Y., J. DE PHYS., Colloque C4, supplément au no 12, Tome 43, C4255 (1982).Google Scholar
12. Eckelmeyer, K.H., Scripta Met., 10, p. 667 (1976).Google Scholar
13. Hwang, C.M., Meichle, M., Salamon, M.B. and Wayman, C.M., Phil. Mag. A, 47, p. 9 (1983).Google Scholar
14. Matsui, H., Enoki, M., Kato, T., J. DE PHYS. IV, Colloque C8, supplément au J. de Phys. III, 5, C81253 (1995).Google Scholar