Hostname: page-component-cd9895bd7-p9bg8 Total loading time: 0 Render date: 2024-12-29T09:17:20.339Z Has data issue: false hasContentIssue false

Interfaces of Molecular Recognition Sites and Biosensors; Novel Bio-Sensing Materials

Published online by Cambridge University Press:  09 June 2015

Kyung M. Choi*
Affiliation:
University of California at Irvine, Irvine CA 92697, U. S. A.
Get access

Abstract

We introduce a sensing element, “Molecularly Imprinted Polymer (MIP),” which created by “Molecular Imprinted Technique.” However, the sensitivity of MIP’s based bio-sensors limits for practical applications due to the low sensitivity. To achieve a high sensitivity of MIP’s based sensors, the synthesis of “high affinity receptor or binding sites,” such as “monoclonal particles” is a key objective. In previous studies, affinity distribution plots indicated that “high affinity binding sites” were obtained when the number of binding sites per particle decreased. It means that smaller particles are expected to have higher affinity binding sites compared to larger particles. The result motivated us to produce small-sized MIP’s particles for the achievement of higher sensitivity. Microfluidic Synthesis has taken a great attention to synthesize small particles. However, the microfluidic synthesis gave us a difficulty, especially collections of MIP’s particles from the surface of PDMS-based microchannels due to a sticking problem. Thus, we employed a new approach, which can collect MIP’s particles without any sticking problem from the surface of the reactor. It is a photopatterned MIP’s system generated on the glass surface. We prepared a photomask with micro-sized patterns and then fabricate MIP’s particles on a glass surface by photopolymerization. Uniform MIP’s patterns were printed on the glass surface. The interface between the glass surface and the MIP’s pattern was observed by SEM. Micro-sized MIP’s particles were collected from the glass surface by scratching off the photocured MIP’s patterns.

Type
Articles
Copyright
Copyright © Materials Research Society 2015 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Conrad, P. G., Nishimura, P. T., Aherne, D., Schwartz, B. J., Wu, D., Fang, N., Zhang, X., Roberts, J. M., and Shea, K. J., Adv. Mater. 15, 1541 (2003).CrossRefGoogle Scholar
Choi, K. M. and Rogers, J. A., J. Am. Chem. Soc. 125, 4060 (2003).CrossRefGoogle Scholar
Choi, K. M., Phys, J.. Chem. B. 109, 21525 (2005).CrossRefGoogle Scholar
Choi, K. M., Research Letters in Materials Science 2008, 458158 (2008).CrossRefGoogle Scholar
Shea, K. J., Lee, A. P., and Mingdi, Y., PMSE Preprints 90, 160 (2004).Google Scholar
Jensen, K. and Lee, A. P., Lab. Chip. 4, 31N (2004).CrossRefGoogle Scholar
Reyes, D. R., Lossifidis, D., Auroux, P.A., and Manz, A., Anal. Chem. 74, 2623 (2002).CrossRefGoogle Scholar
Tan, Y. C., Fisher, J. S., Lee., A. I. V., Cristini, V, and Lee, A. P., Lab. Chip. 4, 292 (2004).CrossRefGoogle Scholar
Zheng, B., Tice, J. D., and Ismagilov, R. F., Anal. Chem. 76, 4977 (2004).CrossRefGoogle Scholar
Edel, J. B., Fortt, R., DeMello, J. C., and DeMello, A. J., Chem. Commun. 10, 1136 (2002).CrossRefGoogle Scholar
Shestopalov, I., Tice, J. D., and Ismagilov, R. F., Lab. Chip. 4, 316 (2004).CrossRefGoogle Scholar
Hung, L.-H., Tseng, W.-Y., Choi, K. M., Tan, Y.-C., Shea, K. J., and Lee, A. P., Proc. MicroTAS 2004 2, 539 (2004).Google Scholar
Okushima, S., Nisisako, T., Torii, T., and Higuchi, T., Proc. MicroTAS 2004 1, 258 (2004).Google Scholar