No CrossRef data available.
Article contents
Localized 56Fe+ ion implantation of TiO2 using anodic porous alumina
Published online by Cambridge University Press: 31 January 2011
Abstract
We present result following localized ion implantation of rutile titanium dioxide (TiO2) using anodic porous alumina as a mask. The implantation were performed with 100 keV 56Fe+ ions using a fluence of 1.3·1016 ions/cm2. The surface modifications where studied by means of SEM, AFM/MFM and XRD. A well-defined hexagonal pattern of modified material in the near surface structure is observed. Local examination of the implanted areas revealed no clear magnetic signal. However, a variation in mechanical and electrostatic behavior between implanted and non-implanted zones is inferred from the variation in AFM signals.
- Type
- Research Article
- Information
- MRS Online Proceedings Library (OPL) , Volume 1181: Symposium DD – Ion Beams and Nano-Engineering , 2009 , 1181-DD01-04
- Copyright
- Copyright © Materials Research Society 2009