Hostname: page-component-78c5997874-xbtfd Total loading time: 0 Render date: 2024-11-10T08:33:06.664Z Has data issue: false hasContentIssue false

Thermal Conductivity of Boron Carbides

Published online by Cambridge University Press:  25 February 2011

Marvin Moss*
Affiliation:
Sandia National Laboratories, Albuquerque, NM 87185.
Get access

Abstract

The thermal conductivity, k, of boron carbides of various B/C ratios, two modes of preparation – hot pressed and carbothermic, and two isotopic variants of boron – 11B and normal boron 10.81B, was measured from 300 to 1023 K. The density and composition of the samples were reflected in the magnitude and temperature dependence of k, and were investigated further with scanning electron microscopy, Rutherford backscattering spectroscopy, and Raman spectroscopy. While lower than theoretical density in B4C reduces k, the characteristic monotonic decline of k with increasing temperature is retained. This k-vs.-T behavior distinguishes B4C from material with larger B/C ratios for which the temperature dependence is essentially nil.

Type
Research Article
Copyright
Copyright © Materials Research Society 1987

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Slack, G. A., Phys. Rev. B 4, 1714 (1971).Google Scholar
2. Wood, C., Emin, D., and Gray, P. E., Phys. Rev. B 31, 6811 (1985).Google Scholar
3. Murgatroyd, R. A. and Kelley, B. T., Atomic Energy Rev. 15, 3 (1977).Google Scholar
4. Türkes, P. R. H., Swartz, E. T., and Pohl, R. O., in AlP Conference Proceedings 140: Boron-Rich Solids, edited by D. Emin et al., (American Institute of Physics, New York, 1986), p. 346.Google Scholar
5. Bouchacourt, M. and Thevenot, F., J. Mat. Sci. 20, 1237 (1985).Google Scholar
6. Emin, D., Phys. Today 40 (1), 5562 (1987).Google Scholar
7. The Colora Thermoconductometer is manufactured by Colora Messtechnik GMBH, Lorch/Wdrttemberg, and sold by Dynatech R/D Company, Cambridge, MA. The Model TCFCM comparative thermal conductivity instrument is manufactured and distributed by Dynatech. Reference to a particular product or company implies neither a recommendation nor an endorsement by Sandia National Laboratories, nor a lack of suitable substitutes.Google Scholar
8. Moss, M., Koski, J. A., and Haseman, G. M., Sandia National Laboratories Report No. SAND82–0109, 1986.Google Scholar
9. Sweet, J. N., Roth, E. P., Moss, M., Haseman, G. M., and Anaya, A. J., Sandia National Laboratories Report No. SAND86–0840, 1986.Google Scholar
10. Sweet, J. N., Int. J. Thermophysics 7, 743 (1986).Google Scholar
11. Sweet, J. N., Roth, E. P, and Moss, M., Int. J. Thermophysics 8, 593 (1987).Google Scholar
12. Sweet, J. N., Moss, M., and Sisson, C. E., in Thermal Conductivity 18, edited by Ashworth, T. and Smith, D. R., (Plenum Publishing Corp., New York, 1985), p. 43.Google Scholar
13. Gilchrist, K. E. and Preston, S. D., High Temp.- High Press. 11, 643 (1979).Google Scholar
14. Ihara, S., Tanaka, K., Kojima, M., and Akimoto, Y., 1973 IAEA IWGFR Specialists Meeting, Dimitrovgrad, USSRGoogle Scholar